Differences in injection rates on contrast-enhanced breath-hold three-dimensional MR angiography.

L Kopka1, R Vosshenrich, J Rodenwaldt, E Grabbe.   

Abstract

OBJECTIVE: The aim of the study was to evaluate the optimization of injection rates with an automatic power injector versus manual injection for contrast-enhanced breath-hold three-dimensional (3D) MR angiography of the abdominal aorta and its branches. SUBJECTS AND METHODS: In a prospective study, 50 patients underwent breath-hold 3D MR angiography (5/2 [TR/TE]; flip angle, 30 degrees) of the abdominal vessels on a 1.5-T system. Each patient received 0.15 mmol/kg of gadopentetate dimeglumine. All patients were randomly assigned to one of five equally sized groups. The contrast bolus was injected manually in group 1, always by the same investigator, who tried to perform a steady injection rate of 2 ml/sec. An automatic injector was used in groups 2-5 with injection flow rates of 0.5 ml/sec, 2 ml/sec, 4 ml/sec, and 6 ml/sec. The start of the MR sequence was tailored individually to the applied volume of contrast material after determination of circulation times by a test bolus. We measured the signal-to-noise and contrast-to-noise ratios as well as the relative vascular enhancement. The visualization of different abdominal vessel segments was independently ranked on a scale of 1-5 (1 = not visible; 5 = excellent visualization) by three reviewers who were unaware of the applied contrast material injection rate.
RESULTS: The signal-to-noise and contrast-to-noise ratios of groups 3 and 4 (2 ml/sec and 4 ml/sec, respectively) were significantly (p < .05) higher than the ratios of groups 1, 2, and 5. The average relative vascular enhancement of groups 3 and 4 was significantly higher (p < .05) than the enhancement of all other groups. The contrast bolus applied with a faster injection rate (group 5) did not cover large parts of the K-space, resulting in increased blurring of the vessel contours. The subjective evaluation of large and small diameter vessels showed significantly better results in groups 3 and 4 than in groups 1, 2, and 5.
CONCLUSION: The use of an automatic MR power injector proved superior to manual injection of contrast material. The optimal injection rate was 2 ml/sec for 3D breath-hold MR angiography of the abdominal vessels.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9456943     DOI: 10.2214/ajr.170.2.9456943

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  10 in total

1.  Contrast enhanced body magnetic resonance angiography.

Authors:  A E Stillman
Journal:  Int J Card Imaging       Date:  1999-04

2.  Dose optimization of contrast-enhanced carotid MR angiography.

Authors:  M Unterweger; J M Froehlich; R A Kubik-Huch; B Seifert; M Birrer; T Huber; R Otto
Journal:  Eur Radiol       Date:  2005-05-05       Impact factor: 5.315

3.  Magnetic resonance angiography for anatomical evaluation of the great arteries.

Authors:  T Oosterhof; B J M Mulder
Journal:  Int J Cardiovasc Imaging       Date:  2005 Apr-Jun       Impact factor: 2.357

4.  Analysis of the influence of 4D MR angiography temporal resolution on time-to-peak estimation error for different cerebral vessel structures.

Authors:  N D Forkert; T Illies; D Möller; H Handels; D Säring; J Fiehler
Journal:  AJNR Am J Neuroradiol       Date:  2012-05-03       Impact factor: 3.825

5.  The optimization of scan timing for contrast-enhanced magnetic resonance angiography.

Authors:  J J Lee; P J Tirman; Y Chang; H K Ryeom; S K Lee; Y S Kim; D S Kang
Journal:  Korean J Radiol       Date:  2000 Jul-Sep       Impact factor: 3.500

6.  Contrast-enhanced magnetic resonance angiography: dose the test dose bolus represent the main dose bolus accurately?

Authors:  J J Lee; Y Chang; D S Kang
Journal:  Korean J Radiol       Date:  2000 Apr-Jun       Impact factor: 3.500

7.  Contrast-enhanced MR angiography of supraaortic vessels: the effect of voxel size on image quality.

Authors:  X Leclerc; L Nicol; J Y Gauvrit; V Le Thuc; D Leys; J P Pruvo
Journal:  AJNR Am J Neuroradiol       Date:  2000 Jun-Jul       Impact factor: 3.825

8.  The impact of injector-based contrast agent administration in time-resolved MRA.

Authors:  Johannes Budjan; Ulrike I Attenberger; Stefan O Schoenberg; Hubertus Pietsch; Gregor Jost
Journal:  Eur Radiol       Date:  2017-12-07       Impact factor: 5.315

9.  Crossover comparison of ferumoxytol and gadobenate dimeglumine for abdominal MR-angiography at 3.0 tesla: Effects of contrast bolus length and flip angle.

Authors:  Tilman Schubert; Utaroh Motosugi; Sonja Kinner; Timothy J Colgan; Samir D Sharma; Scott Hetzel; Shane Wells; Camilo A Campo; Scott B Reeder
Journal:  J Magn Reson Imaging       Date:  2016-11-10       Impact factor: 4.813

10.  Evaluation of the effects of Gd complexes used as magnetic resonance imaging contrast agents, on superoxide dismutase: comparison of two methods.

Authors:  J Behra-Miellet; B Gressier; T Dine; C Brunet; M Luyckx; L Ballester; M Cazin; J C Cazin
Journal:  Inflammation       Date:  1999-10       Impact factor: 4.092

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.