Literature DB >> 9456185

Validation of a new counts-based gated single photon emission computed tomography method for quantifying left ventricular systolic function: comparison with equilibrium radionuclide angiography.

D A Calnon1, R J Kastner, W H Smith, D Segalla, G A Beller, D D Watson.   

Abstract

BACKGROUND: Because myocardial wall thickness is smaller than the spatial resolution of single photon emission computed tomography (SPECT) imaging, changes in myocardial wall thickness are related to changes in maximum pixel counts via the partial volume effect, allowing for quantification of regional systolic wall thickening. We have developed a new gated SPECT method for computing the global left ventricular ejection fraction (LVEF) based entirely on changes in maximum regional myocardial counts during systolic contraction. This new method is independent of endocardial edge detection or other geometric measurements. METHODS AND
RESULTS: In 23 patients the gated SPECT method was validated by comparison with radionuclide angiography. The correlation between computed LVEFs was excellent (slope = 0.97, r = 0.91). The measurement of LVEF by gated SPECT was highly reproducible, with minimal intraoperator (slope = 0.97, r = 0.97) or interoperator (slope = 1.00, r = 0.97) variability. Measurements of regional thickening indexes were also reproducible, with a mean intraoperator correlation coefficient of 0.89 +/- 0.05 (range 0.79 to 0.95) for the 14 myocardial regions. Finally, the measurement of LVEF was not significantly influenced by changes in reconstruction filter parameters over a range of cutoff frequencies from 0.16 to 0.28.
CONCLUSIONS: This new counts-based gated SPECT method for measuring global left ventricular systolic function correlates well with radionuclide angiography, is highly reproducible, and has theoretic advantages over geometric methods.

Entities:  

Mesh:

Year:  1997        PMID: 9456185     DOI: 10.1016/s1071-3581(97)90003-9

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  14 in total

1.  Assessment of systolic thickening with thallium-201 ECG-gated single-photon emission computed tomography: a parameter for local left ventricular function.

Authors:  T Mochizuki; K Murase; Y Fujiwara; S Tanada; K Hamamoto; W N Tauxe
Journal:  J Nucl Med       Date:  1991-08       Impact factor: 10.057

2.  Quantitative gated single photon emission computed tomography imaging: a counts-based method for display and measurement of regional and global ventricular systolic function.

Authors:  W H Smith; R J Kastner; D A Calnon; D Segalla; G A Beller; D D Watson
Journal:  J Nucl Cardiol       Date:  1997 Nov-Dec       Impact factor: 5.952

3.  Left ventricular ejection fraction from gated SPET myocardial perfusion studies: a method based on the radial distribution of count rate density across the myocardial wall.

Authors:  H Everaert; P R Franken; P Flamen; M Goris; A Momen; A Bossuyt
Journal:  Eur J Nucl Med       Date:  1996-12

4.  A new method for noninvasive quantitation of segmental myocardial wall thickening using technetium-99m 2-methoxy-isobutyl-isonitrile scintigraphy--results in normal subjects.

Authors:  C Marcassa; P Marzullo; O Parodi; G Sambuceti; A L'Abbate
Journal:  J Nucl Med       Date:  1990-02       Impact factor: 10.057

5.  Quantitation in positron emission computed tomography: 1. Effect of object size.

Authors:  E J Hoffman; S C Huang; M E Phelps
Journal:  J Comput Assist Tomogr       Date:  1979-06       Impact factor: 1.826

6.  A semi-automated method for edge detection in the evaluation of left ventricular function using ECG-gated single-photon emission tomography.

Authors:  K T Yang; H D Chen
Journal:  Eur J Nucl Med       Date:  1994-11

7.  Measurement of left ventricular ejection fraction from gated technetium-99m sestamibi myocardial images.

Authors:  S Boonyaprapa; M Ekmahachai; N Thanachaikun; W Jaiprasert; V Sukthomya; N Poramatikul
Journal:  Eur J Nucl Med       Date:  1995-06

8.  Left ventricular ejection fraction assessed from gated technetium-99m-sestamibi SPECT.

Authors:  E G DePuey; K Nichols; C Dobrinsky
Journal:  J Nucl Med       Date:  1993-11       Impact factor: 10.057

9.  Determining the accuracy of calculating systolic wall thickening using a fast Fourier transform approximation: a simulation study based on canine and patient data.

Authors:  C D Cooke; E V Garcia; S J Cullom; T L Faber; R I Pettigrew
Journal:  J Nucl Med       Date:  1994-07       Impact factor: 10.057

10.  The evaluation of ventricular function using gated myocardial imaging with Tc-99m MIBI.

Authors:  Y C Najm; A D Timmis; M N Maisey; S V Ellam; R Mistry; P V Curry; E Sowton
Journal:  Eur Heart J       Date:  1989-02       Impact factor: 29.983

View more
  17 in total

1.  Good correlation between gated single photon emission computed myocardial tomography and contrast ventriculography in the assessment of global and regional left ventricular function.

Authors:  D E Atsma; C D Bavelaar-Croon; G Germano; P Dibbets-Schneider; B L van Eck-Smit; E K Pauwels; E E van der Wall
Journal:  Int J Card Imaging       Date:  2000-12

2.  Decreased septal wall thickening in patients with left bundle branch block.

Authors:  Tokuo Kasai; E Gordon Depuey; Arshad Ali Shah
Journal:  J Nucl Cardiol       Date:  2004 Jan-Feb       Impact factor: 5.952

3.  Comparison of 16-frame and 8-frame gated SPET imaging for determination of left ventricular volumes and ejection fraction.

Authors:  Sachin M Navare; Frans J T Wackers; Yi-Hwa Liu
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-06-28       Impact factor: 9.236

Review 4.  Techniques for comprehensive two dimensional echocardiographic assessment of left ventricular systolic function.

Authors:  T H Marwick
Journal:  Heart       Date:  2003-11       Impact factor: 5.994

5.  A realistic 3-D gated cardiac phantom for quality control of gated myocardial perfusion SPET: the Amsterdam gated (AGATE) cardiac phantom.

Authors:  Jacco J N Visser; Ellinor Busemann Sokole; Hein J Verberne; Jan B A Habraken; Huybert J F van de Stadt; Joris E N Jaspers; Morgan Shehata; Paul M Heeman; Berthe L F van Eck-Smit
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-02       Impact factor: 9.236

6.  The role of quantitation in clinical nuclear cardiology: the University of Virginia approach.

Authors:  Denny D Watson; William H Smith
Journal:  J Nucl Cardiol       Date:  2007-07       Impact factor: 5.952

7.  Myocardial perfusion and function single photon emission computed tomography.

Authors:  Christopher L Hansen; Richard A Goldstein; Daniel S Berman; Keith B Churchwell; C David Cooke; James R Corbett; S James Cullom; Seth T Dahlberg; James R Galt; Ravi K Garg; Gary V Heller; Mark C Hyun; Lynne L Johnson; April Mann; Benjamin D McCallister; Raymond Taillefer; R Parker Ward; John J Mahmarian
Journal:  J Nucl Cardiol       Date:  2006-11       Impact factor: 5.952

Review 8.  Gated SPECT in assessment of regional and global left ventricular function: major tool of modern nuclear imaging.

Authors:  Aiden Abidov; Guido Germano; Rory Hachamovitch; Daniel S Berman
Journal:  J Nucl Cardiol       Date:  2006 Mar-Apr       Impact factor: 5.952

9.  Quantification of nuclear cardiac images: the Yale approach.

Authors:  Yi-Hwa Liu
Journal:  J Nucl Cardiol       Date:  2007-07       Impact factor: 5.952

10.  An approach to the three-dimensional display of left ventricular function and viability using MRI.

Authors:  Cory Swingen; Ravi Teja Seethamraju; Michael Jerosch-Herold
Journal:  Int J Cardiovasc Imaging       Date:  2003-08       Impact factor: 2.357

View more