The effect of surface topography of retrieved femoral heads on the wear of UHMWPE sockets.

R M Hall1, P Siney, A Unsworth, B M Wroblewski.   

Abstract

The study was undertaken to investigate the association, if any, between the surface roughness of 35 explanted femoral heads and the clinical wear factors of the corresponding polyethylene sockets. The wear of the socket was measured using a shadowgraph technique. The surface topography was investigated using a Rodenstock RM 600 non-contacting profilometer, and six parameters were used to characterise the roughness. Further, qualitative inspections of the femoral surface were undertaken using both a Joel JSM-IC-848 scanning electron microscope and a Zeiss Axiotech microscope with a differential interference contrast facility. Two parameters were found to correlate with the clinical wear factor, namely the skewness of the amplitude distribution function, Sk, and the arithmetic mean roughness, Ra. Simple parameters describing the peak heights of the asperities were found not to have a significant association with the clinical wear factor. The exponent in the power relationship between the arithmetic mean roughness and kclinical was found to be equal to 0.5 (SE: 0.2). This value is significantly smaller than that found in laboratory experiments and may be due to the non-uniform nature of the roughening of the femoral head, three-body wear and the effect of other clinical factors on the wear process. Further, extremely strong correlations were detected between the differing roughness parameters, which would suggest that any attempt to deduce which one is the most important in affecting the wear of the polymeric counterface is fraught with difficulty. However, further investigation of those parameters, such as the reduced peak height or the material filled profile peak area, which may better describe the effect of the counterface on the wear of the UHMWPE surface would appear to be prudent.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9450255     DOI: 10.1016/s1350-4533(97)00032-5

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  7 in total

1.  Increased volumetric wear of polyethylene liners with more than 3 years of shelf-life time.

Authors:  T J S Puolakka; J T Keränen; K A Juhola; K J J Pajamäki; P J Halonen; J K Nevalainen; V Saikko; M U K Lehto; M Järvinen
Journal:  Int Orthop       Date:  2003-04-01       Impact factor: 3.075

2.  Clinical biomechanics of wear in total hip arthroplasty.

Authors:  John J Callaghan; Douglas R Pedersen; Richard C Johnston; Thomas D Brown
Journal:  Iowa Orthop J       Date:  2003

3.  A novel formulation for scratch-based wear modelling in total hip arthroplasty.

Authors:  Karen M Kruger; Nishant M Tikekar; Anneliese D Heiner; Thomas E Baer; John J Lannutti; John J Callaghan; Thomas D Brown
Journal:  Comput Methods Biomech Biomed Engin       Date:  2013-01-10       Impact factor: 1.763

4.  Evaluating the Surface Topography of Pyrolytic Carbon Finger Prostheses through Measurement of Various Roughness Parameters.

Authors:  Andrew Naylor; Sumedh C Talwalkar; Ian A Trail; Thomas J Joyce
Journal:  J Funct Biomater       Date:  2016-04-14

5.  In Response to Michael Wininger's Commentary: Common Roadblocks for Biomaterials Metrologists.

Authors:  Andrew Naylor
Journal:  J Funct Biomater       Date:  2016-07-27

6.  Characteristics of wear particles and wear behavior of retrieved PEEK-on-HXLPE total knee implants: a preliminary study.

Authors:  Xiangchao Meng; Zhe Du; You Wang
Journal:  RSC Adv       Date:  2018-08-28       Impact factor: 4.036

7.  Encoding scratch and scrape features for wear modeling of total joint replacements.

Authors:  Karen M Kruger; Nishant M Tikekar; Anneliese D Heiner; Thomas E Baer; John J Lannutti; John J Callaghan; Thomas D Brown
Journal:  Comput Math Methods Med       Date:  2013-04-11       Impact factor: 2.238

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.