Literature DB >> 9438439

Three-dimensional spiral fMRI technique: a comparison with 2D spiral acquisition.

S Lai1, G H Glover.   

Abstract

A comparison study was performed of 3D and 2D spiral k-space fMRI techniques using BOLD contrast with a 4.25-min finger-tapping task paradigm. The 3D sequence uses the conventional 2D spiral technique in conjunction with Fourier phase encoding in the slice select direction. Characteristics that were compared included image appearances, signal-to-noise ratio (SNR), fluctuation noise, functional contrast-to-noise ratio (fCNR), detected activation areas, inflow effect, and large vessel involvement. The results showed that, with constant total scan time, the 3D spiral acquisition has higher SNR and fCNR despite its slightly higher fluctuation noise. The capability for thin-slice incoherent averaging is a further advantage of 3D over 2D. With these advantages as well as its intrinsic ability for contiguous slices and image reformatting, the 3D spiral fMRI technique may be superior to its 2D counterpart.

Mesh:

Year:  1998        PMID: 9438439     DOI: 10.1002/mrm.1910390112

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  16 in total

Review 1.  Functional magnetic resonance imaging: imaging techniques and contrast mechanisms.

Authors:  A M Howseman; R W Bowtell
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  1999-07-29       Impact factor: 6.237

Review 2.  Spiral imaging in fMRI.

Authors:  Gary H Glover
Journal:  Neuroimage       Date:  2011-10-20       Impact factor: 6.556

3.  A cross-modal system linking primary auditory and visual cortices: evidence from intrinsic fMRI connectivity analysis.

Authors:  Mark A Eckert; Nirav V Kamdar; Catherine E Chang; Christian F Beckmann; Michael D Greicius; Vinod Menon
Journal:  Hum Brain Mapp       Date:  2008-07       Impact factor: 5.038

4.  Three dimensional echo-planar imaging at 7 Tesla.

Authors:  B A Poser; P J Koopmans; T Witzel; L L Wald; M Barth
Journal:  Neuroimage       Date:  2010-02-06       Impact factor: 6.556

5.  Physiological noise in human cerebellar fMRI.

Authors:  Wietske van der Zwaag; João Jorge; Denis Butticaz; Rolf Gruetter
Journal:  MAGMA       Date:  2015-04-18       Impact factor: 2.310

Review 6.  The future of acquisition speed, coverage, sensitivity, and resolution.

Authors:  Lawrence L Wald
Journal:  Neuroimage       Date:  2012-03-06       Impact factor: 6.556

7.  Evaluation of SLIce Dithered Enhanced Resolution Simultaneous MultiSlice (SLIDER-SMS) for human fMRI.

Authors:  An T Vu; Alex Beckett; Kawin Setsompop; David A Feinberg
Journal:  Neuroimage       Date:  2017-02-07       Impact factor: 6.556

8.  Positive Attitude Toward Math Supports Early Academic Success: Behavioral Evidence and Neurocognitive Mechanisms.

Authors:  Lang Chen; Se Ri Bae; Christian Battista; Shaozheng Qin; Tianwen Chen; Tanya M Evans; Vinod Menon
Journal:  Psychol Sci       Date:  2018-01-24

9.  Temporal SNR characteristics in segmented 3D-EPI at 7T.

Authors:  W van der Zwaag; J P Marques; T Kober; G Glover; R Gruetter; G Krueger
Journal:  Magn Reson Med       Date:  2011-06-07       Impact factor: 4.668

10.  Comparison of spiral-in/out and spiral-out BOLD fMRI at 1.5 and 3 T.

Authors:  Alison R Preston; Moriah E Thomason; Kevin N Ochsner; Jeffrey C Cooper; Gary H Glover
Journal:  Neuroimage       Date:  2004-01       Impact factor: 7.400

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.