Literature DB >> 9428142

On the use of envelope and RF signal decorrelation as tissue strain estimators.

S K Alam1, J Ophir.   

Abstract

Bamber and Bush (1995) used the correlation coefficient for freehand elasticity imaging. Varghese and Ophir (1996) found it to be a biased estimator of strain with a large variability. In this study, we systematically investigate the effect of changes in various system and processing parameters on the performance of the correlation coefficient strain estimator, and demonstrate, using simulated data, that noise and frequency-dependent attenuation can introduce variable bias in this estimator.

Mesh:

Year:  1997        PMID: 9428142     DOI: 10.1016/s0301-5629(97)00186-5

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  10 in total

Review 1.  Medical ultrasound: imaging of soft tissue strain and elasticity.

Authors:  Peter N T Wells; Hai-Dong Liang
Journal:  J R Soc Interface       Date:  2011-06-16       Impact factor: 4.118

2.  Analysis of tissue changes, measurement system effects, and motion artifacts in echo decorrelation imaging.

Authors:  Fong Ming Hooi; Anna Nagle; Swetha Subramanian; T Douglas Mast
Journal:  J Acoust Soc Am       Date:  2015-02       Impact factor: 1.840

3.  Analysis of 2-d ultrasound cardiac strain imaging using joint probability density functions.

Authors:  Chi Ma; Tomy Varghese
Journal:  Ultrasound Med Biol       Date:  2014-03-06       Impact factor: 2.998

4.  Experimental study on temperature rise of acoustic radiation force elastography.

Authors:  Marie Tabaru; Hideki Yoshikawa; Takashi Azuma; Rei Asami; Kunio Hashiba
Journal:  J Med Ultrason (2001)       Date:  2012-04-07       Impact factor: 1.314

5.  Stochastic precision analysis of 2D cardiac strain estimation in vivo.

Authors:  E A Bunting; J Provost; E E Konofagou
Journal:  Phys Med Biol       Date:  2014-10-21       Impact factor: 3.609

6.  Catheter Ablation Lesion Visualization With Intracardiac Strain Imaging in Canines and Humans.

Authors:  Vincent Sayseng; Julien Grondin; Vasant A Salgaonkar; Christopher S Grubb; Maryam Basij; Mohammad Mehrmohammadi; Vivek Iyer; Daniel Wang; Hasan Garan; Elaine Y Wan; Elisa E Konofagou
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-04-15       Impact factor: 2.725

7.  Evaluation of Coronary Artery Disease Using Myocardial Elastography with Diverging Wave Imaging: Validation against Myocardial Perfusion Imaging and Coronary Angiography.

Authors:  Julien Grondin; Marc Waase; Alok Gambhir; Ethan Bunting; Vincent Sayseng; Elisa E Konofagou
Journal:  Ultrasound Med Biol       Date:  2017-02-28       Impact factor: 2.998

8.  Comparison of cardiac displacement and strain imaging using ultrasound radiofrequency and envelope signals.

Authors:  Chi Ma; Tomy Varghese
Journal:  Ultrasonics       Date:  2012-11-29       Impact factor: 2.890

9.  Intracardiac myocardial elastography in canines and humans in vivo.

Authors:  Julien Grondin; Elaine Wan; Alok Gambhir; Hasan Garan; Elisa Konofagou
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-02       Impact factor: 2.725

10.  Myocardial Strain Imaging With Electrocardiogram-Gated and Coherent Compounding for Early Diagnosis of Coronary Artery Disease.

Authors:  Julien Grondin; Changhee Lee; Rachel Weber; Elisa E Konofagou
Journal:  Ultrasound Med Biol       Date:  2022-01-19       Impact factor: 2.998

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.