Analysis of tissue changes, measurement system effects, and motion artifacts in echo decorrelation imaging.

Fong Ming Hooi1, Anna Nagle1, Swetha Subramanian1, T Douglas Mast1.   

Abstract

Echo decorrelation imaging, a method for mapping ablation-induced ultrasound echo changes, is analyzed. Local echo decorrelation is shown to approximate the decoherence spectrum of tissue reflectivity. Effects of the ultrasound measurement system, echo signal windowing, electronic noise, and tissue motion on echo decorrelation images are determined theoretically, leading to a method for reduction of motion and noise artifacts. Theoretical analysis is validated by simulations and experiments. Simulated decoherence of the scattering medium was recovered with root-mean-square error less than 10% with accuracy dependent on the correlation window size. Motion-induced decorrelation measured in an ex vivo pubovisceral muscle model showed similar trends to theoretical motion-induced decorrelation for a 2.1 MHz curvilinear array with decorrelation approaching unity for 3-4 mm elevational displacement or 1-1.6 mm range displacement. For in vivo imaging of porcine liver by a 7 MHz linear array, theoretical decorrelation computed using image-based motion estimates correlated significantly with measured decorrelation (r = 0.931, N = 10). Echo decorrelation artifacts incurred during in vivo radiofrequency ablation in the same porcine liver were effectively compensated based on the theoretical echo decorrelation model and measured pre-treatment decorrelation. These results demonstrate the potential of echo decorrelation imaging for quantification of heat-induced changes to the scattering tissue medium during thermal ablation.

Entities:  

Mesh:

Year:  2015        PMID: 25697993      PMCID: PMC4336259          DOI: 10.1121/1.4906580

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  56 in total

1.  Maximum-likelihood approach to strain imaging using ultrasound

Authors: 
Journal:  J Acoust Soc Am       Date:  2000-03       Impact factor: 1.840

2.  Characterization of measurement system effects in ultrasonic scattering experiments.

Authors:  R C Waag; J P Astheimer
Journal:  J Acoust Soc Am       Date:  1990-11       Impact factor: 1.840

3.  Modeling ultrasound imaging as a linear, shift-variant system.

Authors:  James Ng; Richard Prager; Nick Kingsbury; Graham Treece; Andrew Gee
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-03       Impact factor: 2.725

4.  Ultrasound monitoring of in vitro radio frequency ablation by echo decorrelation imaging.

Authors:  T Douglas Mast; Daniel P Pucke; Swetha E Subramanian; William J Bowlus; Steven M Rudich; Joseph F Buell
Journal:  J Ultrasound Med       Date:  2008-12       Impact factor: 2.153

5.  Image quality, tissue heating, and frame rate trade-offs in acoustic radiation force impulse imaging.

Authors:  Richard R Bouchard; Jeremy J Dahl; Stephen J Hsu; Mark L Palmeri; Gregg E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-01       Impact factor: 2.725

6.  Hyperecho as the indicator of tissue necrosis during microbubble-assisted high intensity focused ultrasound: sensitivity, specificity and predictive value.

Authors:  Tinghe Yu; Chuanshan Xu
Journal:  Ultrasound Med Biol       Date:  2008-04-18       Impact factor: 2.998

Review 7.  Hepatocellular carcinoma: current management.

Authors:  Charles H Cha; M Wasif Saif; Brett H Yamane; Sharon M Weber
Journal:  Curr Probl Surg       Date:  2010-01       Impact factor: 1.909

8.  Estimating tissue strain from signal decorrelation using the correlation coefficient.

Authors:  T Varghese; J Ophir
Journal:  Ultrasound Med Biol       Date:  1996       Impact factor: 2.998

9.  Exploring potential mechanisms responsible for observed changes of ultrasonic backscattered energy with temperature variations.

Authors:  Xin Li; Goutam Ghoshal; Roberto J Lavarello; Michael L Oelze
Journal:  Med Phys       Date:  2014-05       Impact factor: 4.071

Review 10.  Current status of sonographically guided radiofrequency ablation techniques.

Authors:  See-Ying Chiou; Ji-Bin Liu; Laurence Needleman
Journal:  J Ultrasound Med       Date:  2007-04       Impact factor: 2.153

View more
  7 in total

1.  Numerical analysis of three-dimensional echo decorrelation imaging.

Authors:  Michael T Cox; Mohamed A Abbass; T Douglas Mast
Journal:  J Acoust Soc Am       Date:  2020-06       Impact factor: 1.840

2.  Three-dimensional echo decorrelation monitoring of radiofrequency ablation in ex vivo bovine liver.

Authors:  E Ghahramani Z; P D Grimm; K J Eary; M P Swearengen; E G Sunethra K Dayavansha; T D Mast
Journal:  J Acoust Soc Am       Date:  2022-06       Impact factor: 2.482

3.  Dependence of ultrasound echo decorrelation on local tissue temperature during ex vivo radiofrequency ablation.

Authors:  Swetha Subramanian; Daniel T Schmidt; Marepalli B Rao; T Douglas Mast
Journal:  Phys Med Biol       Date:  2016-03-04       Impact factor: 3.609

4.  Real-Time Spatiotemporal Control of High-Intensity Focused Ultrasound Thermal Ablation Using Echo Decorrelation Imaging in ex Vivo Bovine Liver.

Authors:  Mohamed A Abbass; Jakob K Killin; Neeraja Mahalingam; Fong Ming Hooi; Peter G Barthe; T Douglas Mast
Journal:  Ultrasound Med Biol       Date:  2017-10-23       Impact factor: 2.998

5.  Optimized Echo Decorrelation Imaging Feedback for Bulk Ultrasound Ablation Control.

Authors:  Mohamed A Abbass; Allison-Joy Garbo; Neeraja Mahalingam; Jakob K Killin; T Douglas Mast
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-06-14       Impact factor: 2.725

6.  Echo Decorrelation Imaging of Rabbit Liver and VX2 Tumor during In Vivo Ultrasound Ablation.

Authors:  Tyler R Fosnight; Fong Ming Hooi; Ryan D Keil; Alexander P Ross; Swetha Subramanian; Teckla G Akinyi; Jakob K Killin; Peter G Barthe; Steven M Rudich; Syed A Ahmad; Marepalli B Rao; T Douglas Mast
Journal:  Ultrasound Med Biol       Date:  2016-10-04       Impact factor: 2.998

7.  In vivo ultrasound thermal ablation control using echo decorrelation imaging in rabbit liver and VX2 tumor.

Authors:  Mohamed A Abbass; Syed A Ahmad; Neeraja Mahalingam; K Sameer Krothapalli; Jack A Masterson; Marepalli B Rao; Peter G Barthe; T Douglas Mast
Journal:  PLoS One       Date:  2019-12-05       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.