Abstract

OBJECTIVE: To compare the skeletal stability of wire and screw fixation after advancement genioplasty.
DESIGN: Retrospective study.
SETTING: Teaching hospital and private practice, South Africa.
SUBJECTS: 40 Patients who required advancement genioplasty, 20 in each group.
INTERVENTIONS: Advancement genioplasty measurements made on cephalometric radiographs before and immediately after operation, and at least 6 months later. MAIN OUTCOME MEASURES: Comparison of horizontal and vertical measurements.
RESULTS: In the screw (rigid) group mean horizontal advancement was 6.3 mm followed by a relapse of 0.3 mm during the follow up period. The corresponding figures for the wire (non-rigid) group were 5.8 and 0.5 mm. The two differed significantly in the degree of vertical change but the result is clinically unimportant. There was no difference in the degree of horizontal change.
CONCLUSION: There was no difference in skeletal stability between the two groups.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9427445     DOI: 10.1016/s0266-4356(97)90409-5

Source DB:  PubMed          Journal:  Br J Oral Maxillofac Surg        ISSN: 0266-4356            Impact factor:   1.651


  5 in total

1.  Evaluation of ultrasonic and conventional surgical techniques for genioplasty combined with two different osteosynthesis plates: a cadaveric study.

Authors:  Stephan Christian Möhlhenrich; Nassim Ayoub; Ulrike Fritz; Andreas Prescher; Frank Hölzle; Ali Modabber
Journal:  Clin Oral Investig       Date:  2016-12-28       Impact factor: 3.573

2.  Comparison of rigid and semirigid fixation for advancement genioplasty.

Authors:  Mahaboob Shaik; N Koteswar Rao; N Kiran Kumar; G Prasanthi
Journal:  J Maxillofac Oral Surg       Date:  2012-09-11

3.  Cost comparison of genioplasty: when indicated, wire osteosynthesis is more cost effective than plate and screw fixation.

Authors:  David S Precious; Alvaro B Cardoso; Mônica Christine A C Cardoso; Jean-Charles Doucet
Journal:  Oral Maxillofac Surg       Date:  2013-11-23

4.  Musculoskeletal Changes as a Sequel to Advancement Genioplasty: A Long-Term Cephalometric Prospective Study.

Authors:  Abhishek Budharapu; Ramen Sinha; David P Tauro; Prabhat K Tiwari
Journal:  J Maxillofac Oral Surg       Date:  2017-06-09

5.  Medpore versus osseous augmentation in genioplasty procedure: A comparison.

Authors:  Shadab Mohammad; Chandra Dhar Dwivedi; R K Singh; Vibha Singh; U S Pal
Journal:  Natl J Maxillofac Surg       Date:  2010-01
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.