Literature DB >> 24431852

Comparison of rigid and semirigid fixation for advancement genioplasty.

Mahaboob Shaik1, N Koteswar Rao2, N Kiran Kumar3, G Prasanthi4.   

Abstract

To compare the skeletal stability of rigid versus semirigid fixation for advancement genioplasty by the assessment of vertical and horizontal measurements pre-operatively and post-operatively on lateral cephalometric radiographs. The study comprised of patients who underwent standard advancement genioplasty by inferior osteotomy of the chin with broadest musculoperiosteal pedicle with either rigid fixation or wire fixation. The displacements of vertical and horizontal measurements resulting following surgery was derived by calculating the difference between preoperative, immediate post-operative and 1 year post-operatively on lateral cephalometric radiographs. Preoperative measurements were marked as T1, immediate post-operative as T2, 1 year follow up post-operative as T3. In the semirigid group a mean horizontal advancement of 5.97 mm was accompanied by a relapse of 1.623 mm during a period of minimum 1 year. The mean superior repositioning of menton was 0.7 mm. This was accompanied by a relapse of 0.325 mm during a period of 1 year. In the rigid group a mean horizontal advancement of 4.815 mm was accompanied by a relapse of 0.2 mm during a period of 1 year. The mean superior repositioning of menton was 0.975 mm. This was accompanied by a relapse of 0.1 mm during a period of 1 year. This study confirms the findings of several previous studies that contribute data specific towards the use of rigid fixation in advancement genioplasty. In our study we also observed that, in cases where large advancements are necessary, wire fixation may offer insufficient means of fixation particularly if the movement is complex and asymmetrical, in which case rigid fixation devices are more helpful.

Entities:  

Keywords:  Advancement; Genioplasty; Resorption; Rigid and semirigid fixation

Year:  2012        PMID: 24431852      PMCID: PMC3777031          DOI: 10.1007/s12663-012-0430-2

Source DB:  PubMed          Journal:  J Maxillofac Oral Surg        ISSN: 0972-8270


  9 in total

1.  HORIZONTAL OSTEOTOMY OF THE MANDIBLE.

Authors:  J M CONVERSE; D WOOD-SMITH
Journal:  Plast Reconstr Surg       Date:  1964-11       Impact factor: 4.730

2.  The surgical correction of mandibular prognathism and retrognathia with consideration of genioplasty. I. Surgical procedures to correct mandibular prognathism and reshaping of the chin.

Authors:  R TRAUNER; H OBWEGESER
Journal:  Oral Surg Oral Med Oral Pathol       Date:  1957-07

3.  A retrospective study of advancement genioplasty using a special bone plate.

Authors:  C E DeFreitas; E Ellis; D P Sinn
Journal:  J Oral Maxillofac Surg       Date:  1992-04       Impact factor: 1.895

4.  Screw osteosynthesis compared with wire osteosynthesis in advancement genioplasty: a retrospective study of skeletal stability.

Authors:  J P Reyneke; T Johnston; W J van der Linden
Journal:  Br J Oral Maxillofac Surg       Date:  1997-10       Impact factor: 1.651

5.  Cephalometrics for orthognathic surgery.

Authors:  C J Burstone; R B James; H Legan; G A Murphy; L A Norton
Journal:  J Oral Surg       Date:  1978-04

6.  Microangiographic and histologic evaluation of revascularization and healing after genioplasty by osteotomy of the inferior border of the mandible.

Authors:  K A Storum; W H Bell; H Nagura
Journal:  J Oral Maxillofac Surg       Date:  1988-03       Impact factor: 1.895

7.  Skeletal stability following mandibular advancement and rigid fixation.

Authors:  T B Kirkpatrick; M G Woods; J Q Swift; N R Markowitz
Journal:  J Oral Maxillofac Surg       Date:  1987-07       Impact factor: 1.895

8.  The versatility of genioplasty using a broad pedicle.

Authors:  W H Bell; D M Gallagher
Journal:  J Oral Maxillofac Surg       Date:  1983-12       Impact factor: 1.895

Review 9.  A retrospective study of advancement genioplasty.

Authors:  H S Park; E Ellis; R J Fonseca; S T Reynolds; K H Mayo
Journal:  Oral Surg Oral Med Oral Pathol       Date:  1989-05
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.