Literature DB >> 9402202

Phase alignment of multiple surface coil data for reduced bandwidth and reconstruction requirements.

J P Debbins1, J P Felmlee, S J Riederer.   

Abstract

Multiple element surface coils are often used in clinical MRI to increase the image signal-to-noise ratio (S/N). Use of multicoils typically requires increased net sampling bandwidth and data processing for each coil element. A phase-alignment technique is described which combines the signals from all coil elements before image reconstruction, greatly relaxing the technical requirements of the standard multicoil methods. Hardware and software implementations allow reduction of the reconstruction requirement to that of a single coil. The hardware implementation additionally allows a significant reduction in the net sampling bandwidth. The method is applicable to high speed MRI techniques, as demonstrated in phantoms and volunteers.

Mesh:

Year:  1997        PMID: 9402202     DOI: 10.1002/mrm.1910380621

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  7 in total

1.  Determination of appropriate RF blocking impedance for MRI surface coils and arrays.

Authors:  A Kocharian; P J Rossman; T C Hulshizer; J P Felmlee; S J Riederer
Journal:  MAGMA       Date:  2000-06       Impact factor: 2.310

2.  Investigation of complex phased array coil designs for cardiac imaging.

Authors:  M Nittka; A Haase
Journal:  MAGMA       Date:  2000-06       Impact factor: 2.310

3.  Direct magnitude and phase imaging of myelin using ultrashort echo time (UTE) pulse sequences: A feasibility study.

Authors:  Qun He; Yajun Ma; Shujuan Fan; Hongda Shao; Vipul Sheth; Graeme M Bydder; Jiang Du
Journal:  Magn Reson Imaging       Date:  2017-02-20       Impact factor: 2.546

4.  Optimal decay rate constant estimates from phased array data utilizing joint Bayesian analysis.

Authors:  James D Quirk; Alexander L Sukstanskii; G Larry Bretthorst; Dmitriy A Yablonskiy
Journal:  J Magn Reson       Date:  2009-01-13       Impact factor: 2.229

5.  A comparison of coil combination strategies in 3D multi-channel MRSI reconstruction for patients with brain tumors.

Authors:  Maryam Vareth; Janine Lupo; Peder Larson; Sarah Nelson
Journal:  NMR Biomed       Date:  2018-08-31       Impact factor: 4.044

6.  Design of k-space channel combination kernels and integration with parallel imaging.

Authors:  Philip J Beatty; Shaorong Chang; James H Holmes; Kang Wang; Anja C S Brau; Scott B Reeder; Jean H Brittain
Journal:  Magn Reson Med       Date:  2013-08-13       Impact factor: 4.668

Review 7.  RF coils: A practical guide for nonphysicists.

Authors:  Bernhard Gruber; Martijn Froeling; Tim Leiner; Dennis W J Klomp
Journal:  J Magn Reson Imaging       Date:  2018-06-13       Impact factor: 4.813

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.