Literature DB >> 9393901

Total hip arthroplasty with an uncemented femoral component. Excellent results at ten-year follow-up.

J R McLaughlin1, K R Lee.   

Abstract

We followed 138 patients (145 hips) who had had uncemented total hip arthroplasty using the Taperloc femoral component for a mean of ten years (8 to 12.5). No patient was lost to follow-up; 31 (31 hips) died before the minimum time of eight years for inclusion in the study, and 30 of these still had their femoral component in place. One well-fixed prosthesis had been exchanged at the time of acetabular revision. Of the remaining 114 hips, one femoral component required revision for aseptic loosening and one for sepsis. Three other well-fixed femoral components were removed during acetabular revision. Complete clinical and radiological follow-up was obtained in the 109 hips which had not had revision. Clinically, 94 (87%) were rated good or excellent, eight (7%) fair and seven (6%) poor. The average Harris hip score increased from 48 before operation to 88 at the time of the last follow-up. Radiologically, 103 hips (94%) had fixation by bone ingrowth, three (3%) showed stable fibrous ingrowth and three (3%) were unstable. Osteolysis of the fomoral cortex was seen in seven hips (6%), with major lysis in only one. At a mean follow-up of ten years, the results of the Taperloc femoral component are comparable with those of modern techniques of cementing in primary total hip arthroplasty.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9393901     DOI: 10.1302/0301-620x.79b6.7482

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  21 in total

1.  Analysis of migration of the Nanos® short-stem hip implant within two years after surgery.

Authors:  Stefan Budde; Frank Seehaus; Michael Schwarze; Christof Hurschler; Thilo Floerkemeier; Henning Windhagen; Yvonne Noll; Max Ettinger; Fritz Thorey
Journal:  Int Orthop       Date:  2015-09-25       Impact factor: 3.075

2.  [The femoral neck prosthesis CUT. Three- to six-year results].

Authors:  S A Ender; A Machner; G Pap; H Grasshoff; H W Neumann
Journal:  Orthopade       Date:  2006-08       Impact factor: 1.087

3.  Survivorship of 2000 tapered titanium porous plasma-sprayed femoral components.

Authors:  Adolph V Lombardi; Keith R Berend; Thomas H Mallory; Michael D Skeels; Joanne B Adams
Journal:  Clin Orthop Relat Res       Date:  2008-10-31       Impact factor: 4.176

4.  Cementless total hip arthroplasty in patients with rheumatoid arthritis using a tapered designed titanium hip stem minimum: 10-year results.

Authors:  Hans D Carl; Jan Ploetzner; Bernd Swoboda; Gerd Weseloh; Lutz Arne Mueller
Journal:  Rheumatol Int       Date:  2009-12-18       Impact factor: 2.631

5.  Total hip replacement arthroplasty with Mallory-Head system--minimum ten-year follow-up results.

Authors:  Joo-Hyoun Song; Dong-Hyun Kim; Juyoung Kim
Journal:  Int Orthop       Date:  2012-08-04       Impact factor: 3.075

6.  The uncemented Bicontact total hip arthroplasty in octogenarians. Medium-term results.

Authors:  N P Badhe; R C Quinnell; P W Howard
Journal:  Eur J Orthop Surg Traumatol       Date:  2002-12-18

7.  Bipolar Hemarthroplasty Using Cementless Conical Stem for Treatment of Dorr Type B and C Femoral Neck Fracture.

Authors:  Jeong Hoon Kang; Sang Hong Lee; Sung Jung
Journal:  Hip Pelvis       Date:  2015-12-30

8.  A short tapered stem reduces intraoperative complications in primary total hip arthroplasty.

Authors:  Ryan G Molli; Adolph V Lombardi; Keith R Berend; Joanne B Adams; Michael A Sneller
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

9.  A stature-specific concept for uncemented, primary total hip arthroplasty.

Authors:  Georg W Omlor; Hannah Ullrich; Knut Krahmer; Alexander Jung; Günther Aldinger; Peter Aldinger
Journal:  Acta Orthop       Date:  2010-02       Impact factor: 3.717

Review 10.  Hip resurfacing versus total hip arthroplasty: a systematic review comparing standardized outcomes.

Authors:  Deborah A Marshall; Karen Pykerman; Jason Werle; Diane Lorenzetti; Tracy Wasylak; Tom Noseworthy; Donald A Dick; Greg O'Connor; Aish Sundaram; Sanne Heintzbergen; Cy Frank
Journal:  Clin Orthop Relat Res       Date:  2014-04-04       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.