Three-dimensional analysis of multiple wear vectors in retrieved acetabular cups.

M Yamaguchi1, T W Bauer, Y Hashimoto.   

Abstract

The wear of polyethylene acetabular components is an important issue in total hip arthroplasty. The amount of wear has been measured in many studies, but few have addressed other mechanical aspects of wear in vivo. We used the shadowgraph method to measure the wear vectors in 104 retrieved acetabular cups that had been made by a single manufacturer, and we identified more than one wear vector in thirty-one cups (30 per cent). We hypothesized that the most likely explanation of multiple wear vectors was loosening of the acetabular implant with a change in the orientation of the implant in the pelvis. To test this hypothesis, we estimated the extent of motion of the cup in situ on the basis of differences in angles measured from serial radiographs of sixteen hips. We then used linear transformation of the three-dimensional vectors to compare the wear directions measured in the retrieved implants with the wear directions predicted from the radiographs. The change in wear direction predicted on the basis of in vivo motion of the cup never corresponded to the actual difference between wear vectors in the retrieved implants. Our results suggest that multiple wear vectors may be commonly found in retrieved implants, but loosening of the acetabular cup does not account for the multiple vectors. Additional observations suggest that impingement between the edge of the acetabular cup and the femoral component may be associated with multiple wear vectors. These results have implications for the investigation of the general mechanisms of wear in vivo and suggest that clinical or wear-testing scenarios that assume a single direction of wear may underestimate the over-all amount of volumetric wear.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9378740     DOI: 10.2106/00004623-199710000-00011

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  12 in total

1.  Hip-spine relationship: a radio-anatomical study for optimization in acetabular cup positioning.

Authors:  J-Y Lazennec; N Charlot; M Gorin; B Roger; N Arafati; A Bissery; G Saillant
Journal:  Surg Radiol Anat       Date:  2003-11-07       Impact factor: 1.246

2.  Wear analysis of chamfered elongated acetabular cup liners.

Authors:  Hsiao-Che Lin; Tzuo-Liang Luo; Jian-Horng Chen
Journal:  Med Biol Eng Comput       Date:  2011-12-22       Impact factor: 2.602

3.  Wear patterns of, and wear volume formulae for, cylindrically elongated acetabular cup liners.

Authors:  James Shih-Shyn Wu; Shu-Ling Hsu; Jian-Horng Chen
Journal:  Med Biol Eng Comput       Date:  2010-04-28       Impact factor: 2.602

4.  [Comparison of total hip replacements cup orientation and position. Navigation vs. conventional manual implantation of hip prostheses].

Authors:  M Honl; K Schwieger; C H Gauck; F Lampe; M M Morlock; M A Wimmer; E Hille
Journal:  Orthopade       Date:  2005-11       Impact factor: 1.087

5.  Understanding wear in dual mobility total hip replacement: first generation explant wear patterns.

Authors:  Bertrand Boyer; Thomas Neri; Jean Geringer; Alexandre Di Iorio; Remi Philippot; Frederic Farizon
Journal:  Int Orthop       Date:  2016-12-07       Impact factor: 3.075

6.  Effects of design parameters of total hip components on the impingement angle and determination of the preferred liner skirt shape with an adequate oscillation angle.

Authors:  Hsiao-Che Lin; Wei-Min Chi; Ying-Jui Ho; Jian-Horng Chen
Journal:  Med Biol Eng Comput       Date:  2012-11-29       Impact factor: 2.602

Review 7.  2009 Nicolas Andry Award: clinical biomechanics of third body acceleration of total hip wear.

Authors:  Thomas D Brown; Hannah J Lundberg; Douglas R Pedersen; John J Callaghan
Journal:  Clin Orthop Relat Res       Date:  2009-04-28       Impact factor: 4.176

Review 8.  Hip-spine relations and sagittal balance clinical consequences.

Authors:  Jean-Yves Lazennec; Adrien Brusson; Marc-Antoine Rousseau
Journal:  Eur Spine J       Date:  2011-07-28       Impact factor: 3.134

9.  The final follow-up plain radiograph is sufficient for clinical evaluation of polyethylene wear in total hip arthroplasty. A study of validity and reliability.

Authors:  Maiken Stilling; Kristian Larsen; Niels T Andersen; Kjeld Søballe; Søren Kold; Ole Rahbek
Journal:  Acta Orthop       Date:  2010-10       Impact factor: 3.717

10.  Catastrophic Failure of the Acetabular Polyethylene Liner in Ceramic-on-Polyethylene Total Hip Arthroplasty.

Authors:  Givenchy Manzano; Rayna A C Levin; Michael B Mayor; Ran Schwarzkopf
Journal:  J Orthop Case Rep       Date:  2014 Apr-Jun
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.