Literature DB >> 9372798

A new optical 3-D device for the detection of wear.

A Mehl1, W Gloger, K H Kunzelmann, R Hickel.   

Abstract

For the clinical performance of new dental restorative materials to be accurately assessed, the three-dimensional anatomical changes of the functional surfaces of the restoration must be elucidated over time. To this end, a highly accurate 3-D optical scanner has been developed that utilizes the principles of triangulation and a reference-free automated 3-D superimposition software. The aim of this study was to assess the accuracy and the precision of the new system with and without referenced positioning. Additionally, the ability of the system to determine wear of posterior fillings three-dimensionally has been shown. Gypsum replicas of restored teeth were evaluated. The tooth surfaces were scanned with a resolution of 250,000 surface points within a measuring time of 20 to 40 sec. The results show that the precision and accuracy of 3-D data acquisition depend on the surface inclination. Up to an angle of 60 degrees, the precision is better than 3 microns, and the accuracy is better than 6 microns. If exact repositioning of the object before and after occlusal loading is possible, e.g., with in vitro studies, differences on the surface can be determined with a precision of 2.2 microns. In reference-free measurements, which are a necessity in clinical studies, the 3-D data acquisition in combination with the automatic matching program can detect wear with an accuracy of 10 microns. The application of this measuring device for the detection of wear of a composite filling functioning in the mouth has been shown. Since this measuring technique is automated, and measurements of high accuracy can be attained in a short period of time, this system offers the possibility for complex analyses of three-dimensional wear to be conducted on a large number of samples in clinical studies.

Mesh:

Year:  1997        PMID: 9372798     DOI: 10.1177/00220345970760111201

Source DB:  PubMed          Journal:  J Dent Res        ISSN: 0022-0345            Impact factor:   6.116


  29 in total

1.  One-year evaluation of an Ormocer restorative-a multipractice clinical trial.

Authors:  Michael Rosin; Heike Steffen; Corinna Konschake; Uwe Greese; Dirk Teichmann; Axel Hartmann; Georg Meyer
Journal:  Clin Oral Investig       Date:  2003-02-04       Impact factor: 3.573

2.  Fully automatic CAD design of the occlusal morphology of partial crowns compared to dental technicians' design.

Authors:  Andreas P Litzenburger; Reinhard Hickel; Maria J Richter; Albert C Mehl; Florian A Probst
Journal:  Clin Oral Investig       Date:  2012-03-27       Impact factor: 3.573

3.  Comparison of chairside and laboratory CAD/CAM to conventional produced all-ceramic crowns regarding morphology, occlusion, and aesthetics.

Authors:  Maximilian Kollmuss; Stefan Kist; Julia Eliette Goeke; Reinhard Hickel; Karin Christine Huth
Journal:  Clin Oral Investig       Date:  2015-08-07       Impact factor: 3.573

4.  Occlusal splint for sleep bruxism: an electromyographic associated to Helkimo Index evaluation.

Authors:  Leonardo Lopes do Nascimento; César Ferreira Amorim; Lilian Chrystiane Giannasi; Claudia Santos Oliveira; Sérgio Roberto Nacif; Alecsandro de Moura Silva; Daniela Fernandes Figueira Nascimento; Leonardo Marchini; Luis Vicente Franco de Oliveira
Journal:  Sleep Breath       Date:  2008-08       Impact factor: 2.816

5.  Clinical performance and wear characteristics of veneered lithia-disilicate-based ceramic crowns.

Authors:  Kallaya Suputtamongkol; Kenneth J Anusavice; Chatcharee Suchatlampong; Phira Sithiamnuai; Chantana Tulapornchai
Journal:  Dent Mater       Date:  2007-08-28       Impact factor: 5.304

6.  Comparison of biogenerically reconstructed and waxed-up complete occlusal surfaces with respect to the original tooth morphology.

Authors:  Maximilian Kollmuss; Franz-Michael Jakob; Hans-Georg Kirchner; Nicoleta Ilie; Reinhard Hickel; Karin Christine Huth
Journal:  Clin Oral Investig       Date:  2012-05-13       Impact factor: 3.573

7.  Influence of material surface on the scanning error of a powder-free 3D measuring system.

Authors:  Michael Kurz; Thomas Attin; Albert Mehl
Journal:  Clin Oral Investig       Date:  2015-03-07       Impact factor: 3.573

8.  [Evaluation of wear property of Giomer and universal composite in vivo].

Authors:  H L Mu; F C Tian; X Y Wang; X J Gao
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2020-12-21

9.  Antagonist wear of monolithic zirconia crowns after 2 years.

Authors:  Ulrich Lohbauer; Sven Reich
Journal:  Clin Oral Investig       Date:  2016-06-09       Impact factor: 3.573

10.  Digital dentistry: Unraveling the mysteries of computer-aided design computer-aided manufacturing in prosthodontic rehabilitation.

Authors:  Hari Parkash
Journal:  Contemp Clin Dent       Date:  2016 Jul-Sep
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.