Literature DB >> 9368124

The design of an animal PET: flexible geometry for achieving optimal spatial resolution or high sensitivity.

S Weber, A Terstegge, H Herzog, R Reinartz, P Reinhart, F Rongen, H W Müller-Gärtner, H Halling.   

Abstract

We present the design of a positron emission tomograph (PET) with flexible geometry dedicated to in vivo studies of small animals (TierPET). The scanner uses two pairs of detectors. Each detector consists of 400 small individual yttrium aluminum perovskite (YAP) scintillator crystals of dimensions 2 x 2 x 15 mm3, optically isolated and glued together, which are coupled to position-sensitive photomultiplier tubes (PSPMT's). The detector modules can be moved in a radial direction so that the detector-to-detector spacing can be varied. Special hardware has been built for coincidence detection, position detection, and real-time data acquisition, which is performed by a PC. The single-event data are transferred to workstations where the radioactivity distribution is reconstructed. The dimensions of the crystals and the detector layout are the result of extensive simulations which are described in this report, taking into account sensitivity, spatial resolution and additional parameters like parallax error or scatter effects. For the three-dimensional (3-D) reconstruction a genuine 3-D expectation-maximization (EM)-algorithm which can include the characteristics of the detector system has been implemented. The reconstruction software is flexible and matches the different detector configurations. The main advantage of the proposed animal PET scanner is its high flexibility, allowing the realization of various detector-system configurations. By changing the detector-to-detector spacing, the system is capable of either providing good spatial resolution or high sensitivity for dynamic studies of pharmacokinetics.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9368124     DOI: 10.1109/42.640759

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  3 in total

1.  Performance evaluation of microPET: a high-resolution lutetium oxyorthosilicate PET scanner for animal imaging.

Authors:  A F Chatziioannou; S R Cherry; Y Shao; R W Silverman; K Meadors; T H Farquhar; M Pedarsani; M E Phelps
Journal:  J Nucl Med       Date:  1999-07       Impact factor: 10.057

Review 2.  Imaging transgene expression with radionuclide imaging technologies.

Authors:  S S Gambhir; H R Herschman; S R Cherry; J R Barrio; N Satyamurthy; T Toyokuni; M E Phelps; S M Larson; J Balatoni; R Finn; M Sadelain; J Tjuvajev; R Blasberg
Journal:  Neoplasia       Date:  2000 Jan-Apr       Impact factor: 5.715

Review 3.  Pre-clinical PET/MR: technological advances and new perspectives in biomedical research.

Authors:  Hans F Wehrl; Martin S Judenhofer; Stefan Wiehr; Bernd J Pichler
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-03       Impact factor: 9.236

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.