Literature DB >> 9357590

Automatic stenosis detection and quantification in renal arteriography.

I Cherrak1, J F Paul, M C Jaulent, G Chatellier, P F Plouin, J C Gaux, P Degoulet.   

Abstract

Visual assessment of the degree of renal artery stenosis on renal arteriography has a large inter- and intraobserver variability. This degree is usually estimated by the ratio between the most narrowed portion of the artery and the reference diameter. The latter is a priori unknown information and thus operator dependent. The objective of the present work was to test the performances of a computer system that was designed to analyze and quantify lesions on 2D renal arteriograms. The main hypothesis was to consider that the most frequent diameter computed along the artery was a good candidate to approximate the reference diameter. Forty nine patient images were collected from the EMMA randomized trial, a multicenter study comparing two treatment strategies in unilateral atheromatous renal artery stenosis of at least 60%. For each image, the degree of stenosis was evaluated by five independent experts and the mean value was used to represent the gold standard for the computer system. The system is based on a fuzzy automaton and performs a syntactic analysis of the arterial segment providing automatic and reproducible quantification of lesions. Both the radiologist caring for the patient and the system were compared to the gold standard. Compared to individual radiologists, the computer system gave a more precise estimation of percent stenosis and did not over or under estimate the severity of the lesion.

Entities:  

Mesh:

Year:  1997        PMID: 9357590      PMCID: PMC2233450     

Source DB:  PubMed          Journal:  Proc AMIA Annu Fall Symp        ISSN: 1091-8280


  8 in total

1.  Coronary artery dimensions from cineangiograms methodology and validation of a computer-assisted analysis procedure.

Authors:  J H Reiber; C J Kooijman; C J Slager; J J Gerbrands; J C Schuurbiers; A Den Boer; W Wijns; P W Serruys; P G Hugenholtz
Journal:  IEEE Trans Med Imaging       Date:  1984       Impact factor: 10.048

2.  Inter- and intra-observer variability in the qualitative categorization of coronary angiograms.

Authors:  J P Herrman; A Azar; V A Umans; E Boersma; G A von Es; P W Serruys
Journal:  Int J Card Imaging       Date:  1996-03

3.  A "significant" stenosis: thirty years on.

Authors:  M J Raphael; R M Donaldson
Journal:  Lancet       Date:  1989-01-28       Impact factor: 79.321

4.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

5.  Variability in the analysis of coronary arteriograms.

Authors:  T A DeRouen; J A Murray; W Owen
Journal:  Circulation       Date:  1977-02       Impact factor: 29.690

6.  Automated extraction, labelling and analysis of the coronary vasculature from arteriograms.

Authors:  A C Dumay; J J Gerbrands; J H Reiber
Journal:  Int J Card Imaging       Date:  1994-09

7.  Description and representation of segmented renal arteries from angiograms.

Authors:  M C Jaulent; J F Paul; P Boittin; P Degoulet
Journal:  Proc Annu Symp Comput Appl Med Care       Date:  1993

8.  Restenosis after a first percutaneous transluminal renal angioplasty.

Authors:  P F Plouin; B Darné; G Chatellier; I Pannier; C Battaglia; A Raynaud; M Azizi
Journal:  Hypertension       Date:  1993-01       Impact factor: 10.190

  8 in total
  1 in total

1.  A fuzzy classification system to predict renal artery restenosis after angioplasty.

Authors:  I Cherrak; M C Jaulent; P Degoulet
Journal:  Proc AMIA Symp       Date:  1998
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.