Literature DB >> 832349

Variability in the analysis of coronary arteriograms.

T A DeRouen, J A Murray, W Owen.   

Abstract

Variability in coronary arteriogram readings was studied by having cine films from ten patients read by eleven readers. Three of the eleven subsequently met as an expert panel to provide a joint evaluation which could serve as a standard. Considerable variability was found between individual readers and between readers and the panel. The average standard deviation for estimation of any segmental stenosis by any single reader was 18%. Disagreement about the number of major vessels with a 70% stenosis occurred 31% of the time. Discrepancies were most likely to occur in analyzing distal arterial segments, in reading nonopacified segments, and during analysis of films showing more severe disease or having poorer technical quality. Recent experience in reading arteriograms seemed to be the most important characteristic in determining the accuracy of a reader. A protocol for the use of three readers is suggested.

Entities:  

Mesh:

Year:  1977        PMID: 832349     DOI: 10.1161/01.cir.55.2.324

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  48 in total

1.  Digital densitometric determination of relative coronary flow distributions.

Authors:  N P Csizmadia; C H Slump; A P Lubbers; M Schrijver; C J Storm
Journal:  Med Biol Eng Comput       Date:  2001-05       Impact factor: 2.602

Review 2.  Invasive assessment of the coronary circulation: intravascular ultrasound and Doppler.

Authors:  David E Newby; Keith A A Fox
Journal:  Br J Clin Pharmacol       Date:  2002-06       Impact factor: 4.335

3.  Comparison of digital and cine coronary arteriography.

Authors:  J C Gurley; S E Nissen
Journal:  Int J Card Imaging       Date:  1990

4.  Intravascular ultrasound imaging of the coronary arteries: an in vitro evaluation of measurement of area of the lumen and atheroma characterisation.

Authors:  M H Anderson; I A Simpson; D Katritsis; M J Davies; D E Ward
Journal:  Br Heart J       Date:  1992-09

Review 5.  The use of computer-assisted diagnosis in cardiac-perfusion nuclear medicine studies: a review.

Authors:  F L Datz; F V Gabor; P E Christian; G T Gullberg; C E Menzel; K A Morton
Journal:  J Digit Imaging       Date:  1992-11       Impact factor: 4.056

6.  Effects of video frame averaging, smoothing and edge enhancement on the accuracy and precision of quantitative coronary arteriography.

Authors:  K M Kavanaugh; I M Pinto; M J McGillem; S F DeBoe; G B Mancini
Journal:  Int J Card Imaging       Date:  1990

7.  Reproducibility of measurements of coronary narrowings by videodensitometry: unreliability of single view measurements.

Authors:  J Balkin; D Rosenmann; M Ilan; M M Zion
Journal:  Int J Card Imaging       Date:  1990

8.  An objective computer system for the quantification of artery stenoses.

Authors:  P F Wankling; R A Perry; A Seth; A C Hunt; X Escaned; J A Newell; M F Shiu
Journal:  Int J Card Imaging       Date:  1990

9.  Second reading of coronary angiograms by radiologists.

Authors:  Leora M Birnbaum; Kristian B Filion; Dominique Joyal; Mark J Eisenberg
Journal:  Can J Cardiol       Date:  2006-12       Impact factor: 5.223

10.  Use of a pressure-sensing wire to detect sequential pressure gradients for ipsilateral vertebral and subclavian artery stenoses.

Authors:  Chung-Pin Liu; Yen-Hung Ling; Hsien-Li Kao
Journal:  AJNR Am J Neuroradiol       Date:  2005-08       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.