Literature DB >> 7707906

Measurements of magnetic field variations in the human brain using a 3D-FT multiple gradient echo technique.

A Ericsson1, J Weis, A Hemmingsson, M Wikström, G O Sperber.   

Abstract

A magnetic resonance 3DFT multiple gradient-echo technique was used for measurements of the proton spectrum for each voxel in the measured slice. Water, fat, magnetic field and T2 distributions in the head of a normal volunteer and a patient with intracerebral hematoma were computed. Magnetic field variations caused by the head were calculated after correction for the static magnetic field inhomogeneity. Large local magnetic field variations up to 3 ppm were found in the human brain near interfaces between air or bone and brain tissues and 0.5 ppm between hematoma and brain tissue. Information about magnetic field variations could be useful for shimming procedures in vivo and for correcting artifacts in imaging and spectroscopy.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7707906     DOI: 10.1002/mrm.1910330205

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  12 in total

1.  1H-spectroscopic imaging with read gradient during acquisition in inhomogeneous fields: analysis, measurement strategy, and data processing.

Authors:  J Weis; A Ericsson; A Hemmingsson
Journal:  MAGMA       Date:  1997-09       Impact factor: 2.310

2.  Multiple-echo proton spectroscopic imaging using time domain parametric spectral analysis.

Authors:  A P Kiefer; V Govindaraju; G B Matson; M W Weiner; A A Maudsley
Journal:  Magn Reson Med       Date:  1998-04       Impact factor: 4.668

3.  Phase-corrected bipolar gradients in multi-echo gradient-echo sequences for quantitative susceptibility mapping.

Authors:  Jianqi Li; Shixin Chang; Tian Liu; Hongwei Jiang; Fang Dong; Mengchao Pei; Qianfeng Wang; Yi Wang
Journal:  MAGMA       Date:  2014-11-20       Impact factor: 2.310

4.  Age-related changes of cerebral autoregulation: new insights with quantitative T2'-mapping and pulsed arterial spin-labeling MR imaging.

Authors:  M Wagner; A Jurcoane; S Volz; J Magerkurth; F E Zanella; T Neumann-Haefelin; R Deichmann; O C Singer; E Hattingen
Journal:  AJNR Am J Neuroradiol       Date:  2012-06-14       Impact factor: 3.825

5.  An in vivo automated shimming method taking into account shim current constraints.

Authors:  H Wen; F A Jaffer
Journal:  Magn Reson Med       Date:  1995-12       Impact factor: 4.668

Review 6.  An illustrated comparison of processing methods for phase MRI and QSM: removal of background field contributions from sources outside the region of interest.

Authors:  Ferdinand Schweser; Simon Daniel Robinson; Ludovic de Rochefort; Wei Li; Kristian Bredies
Journal:  NMR Biomed       Date:  2016-10-07       Impact factor: 4.044

7.  Bevacizumab impairs oxidative energy metabolism and shows antitumoral effects in recurrent glioblastomas: a 31P/1H MRSI and quantitative magnetic resonance imaging study.

Authors:  Elke Hattingen; Alina Jurcoane; Oliver Bähr; Johannes Rieger; Jörg Magerkurth; Sandra Anti; Joachim P Steinbach; Ulrich Pilatus
Journal:  Neuro Oncol       Date:  2011-09-02       Impact factor: 12.300

8.  Quantitative T2, T2*, and T2' MR imaging in patients with ischemic leukoaraiosis might detect microstructural changes and cortical hypoxia.

Authors:  Marlies Wagner; Michael Helfrich; Steffen Volz; Jörg Magerkurth; Stella Blasel; Luciana Porto; Oliver C Singer; Ralf Deichmann; Alina Jurcoane; Elke Hattingen
Journal:  Neuroradiology       Date:  2015-07-31       Impact factor: 2.804

9.  Accelerated echo planar J-resolved spectroscopic imaging in prostate cancer: a pilot validation of non-linear reconstruction using total variation and maximum entropy.

Authors:  Rajakumar Nagarajan; Zohaib Iqbal; Brian Burns; Neil E Wilson; Manoj K Sarma; Daniel A Margolis; Robert E Reiter; Steven S Raman; M Albert Thomas
Journal:  NMR Biomed       Date:  2015-09-07       Impact factor: 4.044

10.  Deep gray matter structures in HIV infection: a proton MR spectroscopic study.

Authors:  D J Meyerhoff; M W Weiner; G Fein
Journal:  AJNR Am J Neuroradiol       Date:  1996-05       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.