Literature DB >> 9347507

Laser Doppler flowmetry: a clinical test of pulpal vitality.

J M Musselwhite1, B Klitzman, W Maixner, E J Burkes.   

Abstract

PROBLEM: A rapid, accurate, noninvasive method of determining pulpal blood flow would be helpful in determining pulpal vitality.
OBJECTIVE: The purpose of this study was to determine if laser Doppler flowmetry can measure induced changes in pulpal blood flow. STUDY
DESIGN: Two percent lidocaine with epinephrine 1:100,000 was infiltrated into the labial vestibule to anesthetize five anterior teeth in healthy human volunteers. Stents were placed on the teeth to stabilize the laser Doppler probes. Measurements of pulpal blood flow were made along with electrocardiograms to record the cardiac cycle.
RESULTS: Laser Doppler flowmetry demonstrated pulpal blood flow and pulse amplitude decreases under test conditions. These decreases were most significant at 10 minutes after the injection of anesthetic with vasoconstrictor.
CONCLUSIONS: Laser Doppler flowmetry was able to measure pulpal blood flow and record changes in blood flow that occurred when epinephrine was used with infiltration anesthesia. The pulse width and the mean flow were dramatically affected as was synchronization with the cardiac cycle.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9347507     DOI: 10.1016/s1079-2104(97)90041-x

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod        ISSN: 1079-2104


  7 in total

1.  In vitro optical detection of simulated blood pulse in a human tooth pulp model.

Authors:  A Niklas; K-A Hiller; A Jaeger; M Brandt; J Putzger; C Ermer; I Schulz; G Monkman; S Giglberger; M Hirmer; S Danilov; S Ganichev; G Schmalz
Journal:  Clin Oral Investig       Date:  2013-10-30       Impact factor: 3.573

2.  Diurnal variations and pulpal status: is there a need for FFT besides LDF?

Authors:  Herman J J Roeykens; Roeland J G De Moor
Journal:  Lasers Med Sci       Date:  2018-06-13       Impact factor: 3.161

3.  Laser Doppler flowmetry: reproducibility, reliability, and diurnal blood flow variations.

Authors:  Herman J J Roeykens; Ellen Deschepper; Roeland J G De Moor
Journal:  Lasers Med Sci       Date:  2016-05-16       Impact factor: 3.161

4.  Detection of atrial fibrillation during pulpal blood flow assessment using Doppler ultrasound: a case report.

Authors:  Chan-Hyun Lee; Euiseong Kim; Dohyun Kim
Journal:  Dentomaxillofac Radiol       Date:  2018-04-13       Impact factor: 2.419

5.  Dental pulp testing: a review.

Authors:  Eugene Chen; Paul V Abbott
Journal:  Int J Dent       Date:  2009-11-12

6.  Evaluation of Nd:YAG laser on partial oxygen saturation of pulpal blood in anterior hypersensitive teeth.

Authors:  Reza Birang; Naser Kaviani; Mehdi Mohammadpour; Ahmad Moghareh Abed; Norbert Gutknecht; Maziar Mir
Journal:  Lasers Med Sci       Date:  2007-07-20       Impact factor: 3.161

7.  Pulp Vitality Testing with a Developed Universal Pulse Oximeter Probe Holder.

Authors:  Živilė Grabliauskienė; Roberta Zamaliauskienė; Greta Lodienė
Journal:  Medicina (Kaunas)       Date:  2021-01-23       Impact factor: 2.430

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.