Simpson's rule for the volumetric ultrasound assessment of atherosclerotic coronary arteries: a study with ECG-gated three-dimensional intravascular ultrasound.

C von Birgelen1, P J de Feyter, E A de Vrey, W Li, N Bruining, A Nicosia, J R Roelandt, P W Serruys.   

Abstract

BACKGROUND: Volumetric intravascular ultrasound (IVUS) assessment provides complementary information on atherosclerotic plaques. The volumes can be calculated by applying Simpson's rule to cross-sectional area data of multiple IVUS images, acquired with a fixed sample spacing, which is the distance (along the vessel's axis) between two images.
OBJECTIVE: To evaluate the effect of different sample spacings on the results of volumetric IVUS measurements.
METHODS: A stepwise electrocardiographically gated IVUS image-acquisition and automated three-dimensional analysis approach was applied to 26 patients. Twenty-eight coronary segments with mild-to-moderate coronary atherosclerosis were examined. Volumetric measurements of five images per mm (i.e. sample spacing 0.2 mm), representing a complete scanning of the coronary segment, were considered the optimal standard, against which volumetric measurements of three, one, and one-half images per mm (i.e. larger sample spacings) were compared.
RESULTS: The lumen, total vessel, and plaque volumes obtained with five images per mm were 183.3 +/- 2.8, 350.6 +/- 141.6, and 167.3 +/- 89.2 mm3. There was an excellent correlation (r = 0.99, P < 0.001) between these data and volumetric measurements with larger sample spacings. The volumetric measurements with larger sample spacings differed on average only by a little (< 0.7%) from the optimal standard measurements. However, a relatively small, but significant, increase in SD of these differences was associated with the wider sample spacings (< 3.6%, P < 0.05).
CONCLUSIONS: The width of the sample spacing has a relatively small but significant impact on the variability of volumetric intravascular ultrasound measurements. This should be considered when designing future volumetric studies. The electrocardiographically gated acquisition of five IVUS images per mm axial length during a stepwise transducer pull-back is an ideal approach, particularly when addressing with IVUS volumetric changes that are assumed small, such as those expected in studies of the progression and regression of atherosclerosis.

Entities:  

Mesh:

Year:  1997        PMID: 9347216     DOI: 10.1097/00019501-199706000-00005

Source DB:  PubMed          Journal:  Coron Artery Dis        ISSN: 0954-6928            Impact factor:   1.439


  5 in total

1.  Quantitative assessment of mild-to-moderate coronary atherosclerosis by computerized border detection in 3D IVUS.

Authors:  Clemen von Birgelen
Journal:  Int J Cardiovasc Imaging       Date:  2003-04       Impact factor: 2.357

2.  In-vivo, cardiac-cycle related intimal displacement of coronary plaques assessed by 3-D ECG-gated intravascular ultrasound: exploring its correlate with tissue deformability identified by palpography.

Authors:  Gastón A Rodriguez-Granillo; Pierfrancesco Agostoni; Héctor M García-García; Pim de Feyter; Patrick W Serruys
Journal:  Int J Cardiovasc Imaging       Date:  2005-10-18       Impact factor: 2.357

3.  Dedicated calibration formulas permit correction of differences between measurements by different IVUS devices as demonstrated in atherosclerotic human coronary arteries in vitro.

Authors:  Marc Hartmann; Clemens von Birgelen; Gary S Mintz; Nadine Deppermann; Olaf Dirsch; Martin G Stoel; Gert K van Houwelingen; Hans W Louwerenburg; Patrick M J Verhorst; Raimund Erbel
Journal:  Int J Cardiovasc Imaging       Date:  2006-04-29       Impact factor: 2.357

4.  Impact of analyzing less image frames per segment for radiofrequency-based volumetric intravascular ultrasound measurements in mild-to-moderate coronary atherosclerosis.

Authors:  Jennifer Huisman; Marc Hartmann; Eline S K Mattern; Gary S Mintz; Mounir W Z Basalus; Gert K van Houwelingen; Patrick M J Verhorst; Clemens von Birgelen
Journal:  Int J Cardiovasc Imaging       Date:  2010-02-27       Impact factor: 2.357

5.  Reproducibility of volumetric intravascular ultrasound radiofrequency-based analysis of coronary plaque composition in vivo.

Authors:  Marc Hartmann; Eline S K Mattern; Jennifer Huisman; Gert K van Houwelingen; Frits H A F de Man; Martin G Stoel; Peter W Danse; Hans W Louwerenburg; Clemens von Birgelen
Journal:  Int J Cardiovasc Imaging       Date:  2008-08-13       Impact factor: 2.357

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.