Literature DB >> 9322595

Heterophilic antibodies remain a problem for the immunoassay laboratory.

G Ward1, L McKinnon, T Badrick, P E Hickman.   

Abstract

The prevalence of heterophilic antibody interference in a modern immunochemiluminometric assay containing blocking agents was determined using thyrotropin as an illustrative example. Serum samples were obtained from 295 consecutive patients who underwent routine thyroid function testing. The following versions of the thyrotropin assay were used: protocol A (zero blocker), protocol B (routine blocker concentration), and protocol C (extra blocker). Ten patients (prevalence 3.4%) had significant levels of heterophilic antibodies (protocol A value greater than 9 SD from the protocol B value). The observed thyrotropin levels for protocols B and C were the same for all patients, consistent with the reagent blockers in routine assays adequately eliminating heterophilic antibody interference. However, seven more patients (0.03%) in series of 21,000 assessed by routine thyroid function testing had discordant results because of a concentration of heterophilic antibodies so high as to overwhelm the added blocking agents.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9322595     DOI: 10.1093/ajcp/108.4.417

Source DB:  PubMed          Journal:  Am J Clin Pathol        ISSN: 0002-9173            Impact factor:   2.493


  17 in total

1.  Wrong biochemistry results.

Authors:  A A Ismail; J H Barth
Journal:  BMJ       Date:  2001-09-29

2.  Frequent false positive beta human chorionic gonadotropin tests in immunoglobulin A deficiency.

Authors:  A K Knight; T Bingemann; L Cole; C Cunningham-Rundles
Journal:  Clin Exp Immunol       Date:  2005-08       Impact factor: 4.330

3.  False serum calcitonin high levels using a non-competitive two-site IRMA.

Authors:  M Tommasi; A Brocchi; A Cappellini; S Raspanti; M Mannelli
Journal:  J Endocrinol Invest       Date:  2001-05       Impact factor: 4.256

4.  Heterophile antibodies may cause falsely lowered serum cortisol values.

Authors:  M J Bolland; W W Chiu; J S Davidson; M S Croxson
Journal:  J Endocrinol Invest       Date:  2005 Jul-Aug       Impact factor: 4.256

5.  Heterophilic antibodies causing falsely high serum calcitonin values.

Authors:  P D Papapetrou; A Polymeris; H Karga; G Vaiopoulos
Journal:  J Endocrinol Invest       Date:  2006-11       Impact factor: 4.256

6.  Dot enzyme-linked immunosorbent assay strip as a screening tool for detection of autoantibody to interferon gamma in sera of suspected cases of adult-onset immunodeficiency.

Authors:  Kritsadee Rattanathammethee; Kriangkrai Chawansuntati; Romanee Chaiwarith; Jutarat Praparattanapan; Khuanchai Supparatpinyo; Jiraprapa Wipasa
Journal:  J Clin Lab Anal       Date:  2018-04-22       Impact factor: 2.352

7.  Therapeutic drug monitoring during pregnancy and lactation: thyroid function assessment in pregnancy-challenges and solutions.

Authors:  Offie P Soldin
Journal:  Ther Drug Monit       Date:  2010-06       Impact factor: 3.681

8.  Interferences in immunoassay.

Authors:  Jill Tate; Greg Ward
Journal:  Clin Biochem Rev       Date:  2004-05

9.  Effect of exogenous circulating anti-bPL antibodies on bovine placental lactogen measurements in foetal samples.

Authors:  Andrea Vivian Alvarez-Oxiley; Noelita Melo de Sousa; Jean-Luc Hornick; Kamal Touati; Gysbert C van der Weijden; Marcel Am Taverne; Otto Szenci; Jean-François Beckers
Journal:  Acta Vet Scand       Date:  2010-02-03       Impact factor: 1.695

10.  Inappropriate treatment of prostate cancer caused by heterophilic antibody interference.

Authors:  Nicolas Henry; Phillipe Sebe; Olivier Cussenot
Journal:  Nat Clin Pract Urol       Date:  2009-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.