Miniaturized ion-selective chip electrode for sensor application.

A Uhlig1, E Lindner, C Teutloff, U Schnakenberg, R Hintsche.   

Abstract

The performance of miniaturized potentiometric cells, with multilayer, planar ion-selective sensors in aqueous electrolyte solutions, human serum, urine, and whole blood, is presented. The basic steps of the fabrication with silicon technology are summarized. The effect of the contact surface between the internal reference system and the ion-sensitive membrane on the analytical characteristics of potassium- and calcium-sensitive sensors is studied. Silicone rubber-, high molecular weight PVC-, carboxylated PVC and aliphatic polyurethane (Tecoflex)-based solvent polymeric membranes were dispensed into anisotropically etched wells on silicon wafers, and the resulted planar sensors were tested in terms of their ion sensitivity (slopes of the cell voltage-pK or pCa calibration curves), long-term stability, and reproducibility. For the assay of potassium in whole blood, the miniaturized potentiometric cell was built in a flow-through manifold. To achieve the required precision, the flow conditions were optimized and the sensors calibrated periodically. The results prove the feasibility of the new sensor design and satisfy the particularly difficult requirements for the analysis of biological samples.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9322440     DOI: 10.1021/ac960957d

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  6 in total

1.  Development of an array of ion-selective microelectrodes aimed for the monitoring of extracellular ionic activities.

Authors:  Olivier T Guenat; Silvia Generelli; Nicolaas F de Rooij; Milena Koudelka-Hep; François Berthiaume; Martin L Yarmush
Journal:  Anal Chem       Date:  2006-11-01       Impact factor: 6.986

2.  Determination of Cr(VI) using an ion selective electrode with SLMs containing Aliquat336.

Authors:  Young-Woo Choi; Seung-Hyeon Moon
Journal:  Environ Monit Assess       Date:  2004-03       Impact factor: 2.513

Review 3.  Electrochemical Sensors for Clinic Analysis.

Authors:  You Wang; Hui Xu; Jianming Zhang; Guang Li
Journal:  Sensors (Basel)       Date:  2008-03-27       Impact factor: 3.576

4.  Development and evaluation of a miniaturized taste sensor chip.

Authors:  Yusuke Tahara; Akihiro Ikeda; Yoshihiro Maehara; Masaaki Habara; Kiyoshi Toko
Journal:  Sensors (Basel)       Date:  2011-10-20       Impact factor: 3.576

5.  TEMPO-Functionalized Carbon Nanotubes for Solid-Contact Ion-Selective Electrodes with Largely Improved Potential Reproducibility and Stability.

Authors:  József Kozma; Soma Papp; Róbert E Gyurcsányi
Journal:  Anal Chem       Date:  2022-05-27       Impact factor: 8.008

6.  A method for estimating intracellular ion concentration using optical nanosensors and ratiometric imaging.

Authors:  Guoxin Rong; Eric H Kim; Kira E Poskanzer; Heather A Clark
Journal:  Sci Rep       Date:  2017-09-07       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.