Literature DB >> 15038542

Determination of Cr(VI) using an ion selective electrode with SLMs containing Aliquat336.

Young-Woo Choi1, Seung-Hyeon Moon.   

Abstract

An ion selective electrode (ISE) for the measurement of Cr(VI), using supported liquid membranes (SLMs), containing tricaprylmethyl ammonium chloride (Aliquat336), was investigated in this study. Aliquat336, as a carrier, had a high selectivity for Cr(VI) in the presence of interfering ions, in the order SO4(2-) > CO3(2-) > Cl(-) > NO2(-) > NO3(-) > I(-) > SCN(-). The composition of the SLM for the detection of Cr(VI) was optimized at 0.169 mL Aliquat336 mL(-1) NPOE (o-nitrophenyl octyl ether) 0.5 g Poly (vinyl chloride), for the preparation of a 19.6 cm2 sheet. The Cr(VI) concentrations were measured, using the SLM prepared in the study, in the range 2.023 x 10(-5) to 0.1 M (1.052 to 5200 ppm). It seemed that the Cr(VI) was transported as a negatively charged monovalent ion, as indicated by the slope of the electromotive force (emt) response. The selectivity coefficients and detection limits for the Cr(VI). against the interfering ions, were determined experimentally using the fixed interference (FIM) and the separate solution methods (SSM).

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15038542     DOI: 10.1023/b:emas.0000014512.18816.cb

Source DB:  PubMed          Journal:  Environ Monit Assess        ISSN: 0167-6369            Impact factor:   2.513


  5 in total

1.  An anion-selective membrane electrode based on a mixture of insoluble lead salts.

Authors:  D Lee; K L Cheng
Journal:  Talanta       Date:  1990-09       Impact factor: 6.057

2.  Development and publication of work with selective ion-sensitive electrodes.

Authors:  G J Moody; J D Thomas
Journal:  Talanta       Date:  1972-05       Impact factor: 6.057

3.  Miniaturized ion-selective chip electrode for sensor application.

Authors:  A Uhlig; E Lindner; C Teutloff; U Schnakenberg; R Hintsche
Journal:  Anal Chem       Date:  1997-10-01       Impact factor: 6.986

4.  A study on hexachromic ion selective electrode based on supported liquid membranes.

Authors:  Y W Choi; S H Moon
Journal:  Environ Monit Assess       Date:  2001-07       Impact factor: 2.513

5.  Effect of pH on chromium(VI) species in solution.

Authors:  R K Tandon; P T Crisp; J Ellis; R S Baker
Journal:  Talanta       Date:  1984-03       Impact factor: 6.057

  5 in total
  2 in total

1.  Functionalization of micro- and nano-apertures with chromate-selective solvent polymeric membrane.

Authors:  Daniel C Rieck; Bingwen Liu; Bong-Jae Park; David F Moffett; David A Kidwell; Gary J Cheng; Bernard J Van Wie
Journal:  Anal Chim Acta       Date:  2009-11-18       Impact factor: 6.558

2.  Paper Strip and Ceramic Potentiometric Platforms Modified with Nano-Sized Polyaniline (PANi) for Static and Hydrodynamic Monitoring of Chromium in Industrial Samples.

Authors:  Saad S M Hassan; Ayman H Kamel; Abd El-Galil E Amr; M Abdelwahab Fathy; Mohamed A Al-Omar
Journal:  Molecules       Date:  2020-01-31       Impact factor: 4.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.