Abstract
A miniaturized taste sensor chip was designed for use in a portable-type taste sensing system. The fabricated sensor chip (40 mm × 26 mm × 2.2 mm) has multiple taste-sensing sites consisting of a poly(hydroxyethyl methacrylate) hydrogel with KCl as the electrolyte layer for stability of the membrane potential and artificial lipid membranes as the taste sensing elements. The sensor responses to the standard taste substances showed high accuracy and good reproducibility, which is comparable with the performance of the sensor probe of the commercialized taste sensing system. Thus, the fabricated taste sensor chip could be used as a key element for the realization of a portable-type taste sensing system.Entities:
Keywords: artificial lipid membrane; electrolyte layer; sensor chip; taste sensor
Mesh:
Substances:
Year: 2011 PMID: 22163731 PMCID: PMC3231247 DOI: 10.3390/s111009878
Source DB: PubMed Journal: Sensors (Basel) ISSN: 1424-8220 Impact factor: 3.576
Figure 1.(a) External view of the commercialized taste sensing system. (b) Extended view of connecter parts with sensor probes and the sensor chip. (c) Structure of the fabricated sensor chip.
Figure 2.Manufacturing procedure for taste sensing site. (a) Forming the electrolyte layer. (b) Setting of the partition. (c) Deposition of artificial lipid membrane solution.
Chemical components of the artificial lipid membranes.
| Saltiness | Tetradodecylammonium chloride | Dioctyl phenylphosphonate |
| Sourness | Phosphoric acid di(2-ethylhexyl) ester | Dioctyl phenylphosphonate |
| Umami | Phosphoric acid di(2-ethylhexyl) ester | Dioctyl phenylphosphonate |
| Bitterness | Tetradodecylammonium chloride | Dioctyl phenylphosphonate |
| Astringency | Tetradodecylammonium chloride | 2-Nitrophenyl octyl ether |
Figure 3.Calibration curves of the taste sensor chips and the sensor probes. Data are expressed as mean ± SD (n = 5). ○: sensor chip, Δ: sensor probe.
Linear regression analysis of the correlation between sensor responses. Reschip: sensor response of the sensor chips; Resprobe: sensor response of the sensor probes.
| Saltiness | 0.99 | |
| Sourness | 0.99 | |
| Umami | 0.99 | |
| Bitterness | 0.99 | |
| Astringency | 0.98 |
Figure 4.Repeatability of measurement of each taste substances by the sensor chips. Data are expressed as mean ± SD (n = 4). Taste substance of saltiness, sourness, umami, bitterness and astringency were used 300 mM KCl in 30 mM tartaric acid, 3 mM tannic acid in 30 mM KCl, 10 mM MSG, 0.01 vol% iso-alpha acid in reference solution and 0.05 wt% tannic acid, respectively.