Performing a breast biopsy with a directional, vacuum-assisted biopsy instrument.

S H Parker1, A J Klaus.   

Abstract

A recently developed method of minimally invasive breast biopsy involves use of a directional, vacuum-assisted instrument. Use of this instrument requires some changes in techniques and applications of breast biopsy, but it enables confident biopsy of breast lesions under both ultrasound (US) and stereotactic guidance. The device uses vacuum to pull tissue into the probe and to remove the specimen without withdrawing the probe each time. For stereotactic biopsy, to target the lesion, the probe is placed anterior or posterior to the lesion and stereotactic positioning views are obtained; for a US-guided procedure, the probe is advanced posterior to the lesion. Next, the direction that the probe aperture must be rotated to face the lesion is determined. Tissue samples are obtained at consecutive clock positions of 1 1/2-hour intervals to achieve contiguous sampling. At least 15 samples are obtained with an 11-gauge probe to acquire a minimum of 1,500 mg of tissue. If postbiopsy images reveal that the lesion has been removed, a percutaneous clip is placed to mark the biopsy site for follow-up examination and possible further treatment. Patients are examined the next day and given the biopsy results and treatment considerations, if needed; they are followed up approximately 1 week later to detect any complications (eg, discomfort, ecchymosis). By learning how to perform a directional, vacuum-assisted biopsy with either stereotactic or US guidance, the radiologist has an additional, valuable tool for bringing accurate breast biopsy to his or her community.

Entities:  

Mesh:

Year:  1997        PMID: 9308112     DOI: 10.1148/radiographics.17.5.9308112

Source DB:  PubMed          Journal:  Radiographics        ISSN: 0271-5333            Impact factor:   5.333


  15 in total

1.  Breast cancer diagnosis: what are we waiting for?

Authors:  P Rasuli
Journal:  CMAJ       Date:  2001-08-07       Impact factor: 8.262

2.  Minimally Invasive Biopsy Methods - Diagnostics or Therapy? Personal Opinion and Review of the Literature.

Authors:  Ute Kettritz
Journal:  Breast Care (Basel)       Date:  2011-04-29       Impact factor: 2.860

3.  Comparison of the underestimation rate in cases with ductal carcinoma in situ at ultrasound-guided core biopsy: 14-gauge automated core-needle biopsy vs 8- or 11-gauge vacuum-assisted biopsy.

Authors:  Y J Suh; M J Kim; E-K Kim; H J Moon; J Y Kwak; H R Koo; J H Yoon
Journal:  Br J Radiol       Date:  2012-03-14       Impact factor: 3.039

Review 4.  Differentiating vacuum-assisted breast biopsy from core needle biopsy: Is it necessary?

Authors:  Satoko Nakano; Yoshimi Imawari; Akemi Mibu; Masahiko Otsuka; Toshinori Oinuma
Journal:  Br J Radiol       Date:  2018-07-20       Impact factor: 3.039

5.  The current role of vacuum assisted breast biopsy system in breast disease.

Authors:  Hai-Lin Park; Lee Su Kim
Journal:  J Breast Cancer       Date:  2011-03-31       Impact factor: 3.588

Review 6.  Modern concepts of ductal carcinoma in situ (DCIS) and its diagnosis through percutaneous biopsy.

Authors:  Ute Kettritz
Journal:  Eur Radiol       Date:  2007-09-27       Impact factor: 5.315

7.  Stereotactic vacuum-assisted breast biopsy in 268 nonpalpable lesions.

Authors:  M Tonegutti; V Girardi
Journal:  Radiol Med       Date:  2008-02-25       Impact factor: 3.469

8.  Hematoma-directed and ultrasound-guided breast-conserving surgery for nonpalpable breast cancer after Mammotome biopsy.

Authors:  Hiroki Inui; Masahiro Watatani; Yukihiko Hashimoto; Toshiya Hojo; Kyoko Hirai; Munehisa Yamato; Makoto Fujishima; Tatsuya Azumi; Hitoshi Shiozaki
Journal:  Surg Today       Date:  2008-02-29       Impact factor: 2.549

9.  False-negative results after stereotactically guided vacuum biopsy.

Authors:  D Peter; J Grünhagen; R Wenke; F K W Schäfer; I Schreer
Journal:  Eur Radiol       Date:  2007-07-19       Impact factor: 5.315

10.  Stereotactic vacuum biopsy of calcifications with a handheld portable biopsy system: a validation study.

Authors:  P Taourel; D Hoa; C Chaveron; C Balu-Maestro; D Gros; M C Baranzelli; F Ettore; M F Bretz-Grenier; P Roger
Journal:  Eur Radiol       Date:  2008-03-20       Impact factor: 7.034

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.