Literature DB >> 9300999

Transfection of a reporter plasmid into cultured cells by sonoporation in vitro.

S Bao1, B D Thrall, D L Miller.   

Abstract

Cultured Chinese hamster ovary cells were exposed to 2.25-MHz ultrasound in sterile 4.5-mL polyethylene chambers and tested for cell lysis, sonoporation and DNA transfection. Ten percent of Albunex, a gas-body-based ultrasound contrast agent, was added to ensure cavitation nucleation, and the chambers were rotated at 60 rpm to promote cavitation activity during the 1-min exposures. Uptake of large fluorescent dextran molecules by some cells was observed for spatial peak pressure amplitudes as low as 0.1 MPa, which indicates transient permeabilization and resealing, i.e., sonoporation, of these cells during exposure. Significant lysis occurred for 0.2 MPa, and increased rapidly for exposures above the apparent cavitation threshold (using the H2O2 production test) of about 0.4 MPa spatial peak pressure amplitude. In the DNA transfection tests, 20 micrograms/mL luciferase reporter plasmid was added to the suspension during exposure, and cells were assayed for proliferation ability and luciferase gene expression 2 days after exposure. Cell proliferation was greatly reduced above the cavitation threshold. Luciferase production was significant for 0.20-MPa exposure, and reached 0.33 ng per 10(6) cells at 0.8-MPa exposure. The luciferase production was great for cells exposed in medium supplemented with serum than for cells exposed in serum-free medium. Cells harvested for exposure either in the log phase or in the stationary phase of culture gave similar proliferation and transfection results. The effects essentially disappeared when the Albunex was omitted from the suspension and the tube was not rotated. Thus, sonoporation by ultrasonic cavitation in the rotating tube system yields plasmid transfection with subsequent transient gene expression.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9300999     DOI: 10.1016/s0301-5629(97)00025-2

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  95 in total

Review 1.  Section 8--clinical relevance. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 2.  Section 6--mechanical bioeffects in the presence of gas-carrier ultrasound contrast agents. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 3.  Section 7--discussion of the mechanical index and other exposure parameters. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 4.  Section 4--bioeffects in tissues with gas bodies. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

5.  Cell loading with laser-generated stress waves: the role of the stress gradient.

Authors:  S E Mulholland; S Lee; D J McAuliffe; A G Doukas
Journal:  Pharm Res       Date:  1999-04       Impact factor: 4.200

6.  An experimental and theoretical analysis of ultrasound-induced permeabilization of cell membranes.

Authors:  Jagannathan Sundaram; Berlyn R Mellein; Samir Mitragotri
Journal:  Biophys J       Date:  2003-05       Impact factor: 4.033

7.  Vascular gene transfer and drug delivery in vitro using low-frequency ultrasound and microbubbles.

Authors:  Hong Yang; Zhong-hua Liu; Yi-yao Liu; Chang-chun Lou; Zheng-long Ren; Hirokazu Miyoshi
Journal:  Acta Pharmacol Sin       Date:  2010-03-29       Impact factor: 6.150

Review 8.  Contrast-enhanced and targeted ultrasound.

Authors:  Michiel Postema; Odd Helge Gilja
Journal:  World J Gastroenterol       Date:  2011-01-07       Impact factor: 5.742

9.  Enhancing cell kill in vitro from hyperthermia through pre-sensitizing with ultrasound-stimulated microbubbles.

Authors:  Goutam Ghoshal; Michael L Oelze
Journal:  J Acoust Soc Am       Date:  2015-12       Impact factor: 1.840

10.  Interrelation between HeLa-S3 cell transfection and hemolysis in red blood cell suspension using pulsed ultrasound of various duty cycles.

Authors:  Y Liu; H Uno; H Takatsuki; M Hirano; A Sakanishi
Journal:  Eur Biophys J       Date:  2004-10-05       Impact factor: 1.733

View more