Literature DB >> 9300987

The 3D and 2D color flow display of breast masses.

P L Carson1, A P Moskalik, A Govil, M A Roubidoux, J B Fowlkes, D Normolle, D D Adler, J M Rubin, M Helvie.   

Abstract

A prospective study was performed in 24 women with breast masses on mammography going on to surgical biopsy. 2D and 3D power mode and frequency shift color flow Doppler scanning and display were compared. Vessels were displayed as rotatable color volumes in 3D, superimposed on gray-scale slices. The latter were stepped sequentially through the imaged volume. Radiologists rated the masses in each display (3D, 2D and videotapes) on a scale of 1 to 5 (5 = most suspicious) for each of six conventional gray-scale and six new vascular criteria. Thirteen masses proved to be benign and 11 were malignant. 3D provided a stronger subjective appreciation of vascular morphology and allowed somewhat better ultrasound discrimination of malignant masses than did the 2D images or videotapes (specificities of 85%, 79% and 71%, respectively, at a sensitivity of 90%). Only in 3D did the vascularity measures display a trend towards significance in this small study.

Entities:  

Mesh:

Year:  1997        PMID: 9300987     DOI: 10.1016/s0301-5629(97)00073-2

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  6 in total

1.  Combination of digital mammography with semi-automated 3D breast ultrasound.

Authors:  Ajay Kapur; Paul L Carson; Jeffrey Eberhard; Mitchell M Goodsitt; Kai Thomenius; Murtuza Lokhandwalla; Donald Buckley; Marilyn A Roubidoux; Mark A Helvie; Rebecca C Booi; Gerald L LeCarpentier; Ramon Q Erkamp; Heang-Ping Chan; J Brian Fowlkes; Jerry A Thomas; Cynthia E Landberg
Journal:  Technol Cancer Res Treat       Date:  2004-08

2.  Rapid 3D imaging of contrast flow: demonstration of a dual beam technique.

Authors:  Nelson G Chen; J Brian Fowlkes; Paul L Carson; Gerald L LeCarpentier
Journal:  Ultrasound Med Biol       Date:  2007-04-27       Impact factor: 2.998

3.  Contrast-enhanced triggered harmonic sonography for assessment of periarticular hemodynamic changes in experimental arthritis.

Authors:  Andrea S Doria; Raffi Karshafian; Rahim Moineddin; Arun Mohanta; Anguo Zhong; Maria Mendes; Kenneth Pritzker; Roland Jong; Peter Burns
Journal:  Pediatr Radiol       Date:  2006-10-19

4.  Three-dimensional ultrasound guidance of autonomous robotic breast biopsy: feasibility study.

Authors:  Kaicheng Liang; Albert J Rogers; Edward D Light; Daniel von Allmen; Stephen W Smith
Journal:  Ultrasound Med Biol       Date:  2010-01       Impact factor: 2.998

5.  Rapid 3-D imaging of contrast flow: application in a perfused kidney phantom.

Authors:  N G Chen; J B Fowlkes; P L Carson; M J Schipper; G L LeCarpentier
Journal:  Ultrasound Med Biol       Date:  2009-04-05       Impact factor: 2.998

6.  Suspicious breast lesions: assessment of 3D Doppler US indexes for classification in a test population and fourfold cross-validation scheme.

Authors:  Gerald L LeCarpentier; Marilyn A Roubidoux; J Brian Fowlkes; Jochen F Krücker; Karen A Hunt; Chintana Paramagul; Timothy D Johnson; Nancy J Thorson; Karen D Engle; Paul L Carson
Journal:  Radiology       Date:  2008-11       Impact factor: 11.105

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.