Literature DB >> 15136905

Impaired poststenotic aortic pulsatility after hemodynamically ideal coarctation repair in children.

J-P Pfammatter1, P Berdat, T Carrel.   

Abstract

Using echocardiographic quantification of aortic pulsatility distal to the site of the surgical anastomosis, we evaluated whether the preoperatively impaired poststenotic aortic pulsatility returned to normal after repair of coarctation with a hemodynamically ideal result. Patients who underwent repair of aortic coarctation without residual obstruction were compared to a matched group of normal children. A standardized M-mode echocardiographic evaluation of the aorta at the diaphragmatic level was performed for all patients. Measurements consisted of maximum and minimum aortic diameters, time intervals, and a calculated pulsatility index. Compared to normal children (n = 19), 20 children with operated coarctation and with a hemodynamically ideal result showed a significantly smaller increase in aortic diameter in systole (mean of 29 +/- 7% in patients versus 37 +/- 7% in normals; p < 0.01). In contrast to patients with coarctation in whom the maximum aortic distension is reached much later during the cardiac cycle, hemodynamically normalized, operated patients in our study had no such delay (maximum aortic pulsation at 28% of cardiac cycle time compared to 27% in normals; p = not significant). The pulsatility index of the poststenotic aorta was clearly lower in operated children (mean, 130 +/- 50%/sec) compared to a normal mean value of 202 +/- 33%/sec but was still significantly higher than that in patients with unoperated coarctation, who showed a low mean value of 51 +/- 24%/sec (p < 0.01). After correction of aortic coarctation with a hemodynamically ideal result, the pulsatility of the poststenotic aorta, severely impaired prior to repair, did not return to normal during the observation period in the patients studied.

Entities:  

Mesh:

Year:  2004        PMID: 15136905     DOI: 10.1007/s00246-004-0633-5

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  7 in total

1.  The effect of implantation of aortic stents on compliance and blood flow. An experimental study in pigs.

Authors:  J Pihkala; G K Thyagarajan; G P Taylor; D Nykanen; L N Benson
Journal:  Cardiol Young       Date:  2001-03       Impact factor: 1.093

2.  Altered systolic and diastolic function in children after "successful" repair of coarctation of the aorta.

Authors:  W B Moskowitz; R M Schieken; M Mosteller; R Bossano
Journal:  Am Heart J       Date:  1990-07       Impact factor: 4.749

3.  Update on the 1987 Task Force Report on High Blood Pressure in Children and Adolescents: a working group report from the National High Blood Pressure Education Program. National High Blood Pressure Education Program Working Group on Hypertension Control in Children and Adolescents.

Authors: 
Journal:  Pediatrics       Date:  1996-10       Impact factor: 7.124

4.  Quantitative echocardiographic characterization of abdominal aortic pulsatility in children with coarctation.

Authors:  J P Pfammatter; F P Stocker
Journal:  Pediatr Res       Date:  1999-07       Impact factor: 3.756

5.  Intravascular ultrasound assessment of regional aortic wall stiffness, distensibility, and compliance in patients with coarctation of the aorta.

Authors:  J Xu; T Shiota; R Omoto; X Zhou; S Kyo; M Ishii; M J Rice; D J Sahn
Journal:  Am Heart J       Date:  1997-07       Impact factor: 4.749

6.  Arterial reactivity is significantly impaired in normotensive young adults after successful repair of aortic coarctation in childhood.

Authors:  H M Gardiner; D S Celermajer; K E Sorensen; D Georgakopoulos; J Robinson; O Thomas; J E Deanfield
Journal:  Circulation       Date:  1994-04       Impact factor: 29.690

7.  Aortic elastic properties in patients with repaired coarctation of aorta.

Authors:  S Brili; J Dernellis; C Aggeli; C Pitsavos; C Hatzos; C Stefanadis; P Toutouzas
Journal:  Am J Cardiol       Date:  1998-11-01       Impact factor: 2.778

  7 in total
  2 in total

1.  Assessment of vascular reactivity in the peripheral and coronary arteries by Cine 3T-magnetic resonance imaging in young normotensive adults after surgery for coarctation of the aorta.

Authors:  Jochem Cuypers; Elisabeth Leirgul; Terje H Larsen; Ansgar Berg; Tom Roar Omdal; Gottfried Greve
Journal:  Pediatr Cardiol       Date:  2012-10-13       Impact factor: 1.655

2.  Pulsatility index in aortic coarctation: a possible way to evaluate factors affecting stenting outcome.

Authors:  Shokoufeh Hajsadeghi; Seyed-Mohammad Fereshtehnejad; Saeid Gholami; Mitra Chitsazan; Mohammad Reza Keramati
Journal:  J Tehran Heart Cent       Date:  2012-02-28
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.