Factors influencing stability at the interface between a porous surface and cancellous bone: a finite element analysis of a canine in vivo micromotion experiment.

B S Ramamurti1, T E Orr, C R Bragdon, J D Lowenstein, M Jasty, W H Harris.   

Abstract

Several factors contribute to the success of stable bony ingrowth into the porous coated surfaces of orthopaedic implants used in hip arthroplasty. Despite having good bony apposition, bony ingrowth might not occur if the relative motion between bone and implant is large. Therefore, determining the limiting micromotion value that inhibits stable bony ingrowth is important. From a previous canine in vivo micromotion study performed at our laboratory, this limiting value was found to be 20 microns. Initially, cementless orthopaedic implants are stabilized only by frictional forces at the bone-implant interface. Therefore, other parameters such as the coefficient of friction and the compressive force normal to the interface should be considered as important factors which stabilize the interface along with micromotion. The purpose of this analytical study was to elucidate how the stability at the bone-implant interface is influenced by various factors, namely, motion of the implant, the coefficient of friction, the degree of pres fit, and the modulus of the surrounding cancellous bone in determining the stability of the bone-implant interface. Nonlinear and linear finite element models which simulated the immediate postsurgical condition and the end point of the canine in vivo micromotion experiment, respectively, were used to this end. From the results of the finite element models it was possible to identify the displacement magnitude for which the implant slipped relative to the bone as the motion of the implant was increased incrementally. This was done for combinations of the coefficient of friction, press fit, and Young's modulus of cancellous bone. This was used as an indicator of the limiting implant motion value beyond which bony ingrowth will be inhibited. The stress distribution in the surrounding cancellous bone bed was also obtained from the results of the finite element analyses for different press-fit conditions. The results of the study indicated that under slight press-fit conditions, the implant slipped relative to bone for implant motions as low as 20 microns. For higher degrees of press fit and reasonable values for the coefficient of friction, no slip occurred for implant motions as much as 100 microns. Although higher degrees of press fit were theoretically conducive to better implant stability, the concomitant high stresses in the adjacent cancellous bone will tend to compromise the integrity of the press fit. This was also evident when the results of an analytical model with a lower degree of press fit correlated well with those of the canine in vivo experiment in which a higher press fit was used, suggesting a possibility of achieving a less than desired press fit during the process of implantation. Through this study the importance of factors other than implant motion was emphasized. The results of the study suggest that the limiting value of implant motion that inhibits bone ingrowth might vary with the degree of press fit for reasonable coefficients of friction.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9261690     DOI: 10.1002/(sici)1097-4636(199708)36:2<274::aid-jbm17>3.0.co;2-g

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  12 in total

1.  Radiographic evaluation of the Duraloc cup after 4 years.

Authors:  B Stoeckl; E Brabec; S Wanner; M Krismer; R Biedermann
Journal:  Int Orthop       Date:  2004-10-14       Impact factor: 3.075

2.  Effects of screw eccentricity on the initial stability of the acetabular cup.

Authors:  Jui-Ting Hsu; Chih-Han Chang; Kai-Nan An; Mark E Zobitz; Rapin Phimolsarnti; Ronald R Hugate; Kuo-An Lai
Journal:  Int Orthop       Date:  2006-09-01       Impact factor: 3.075

3.  Use of freeze-dried bone allografts in revision total hip arthroplasty.

Authors:  Maurice Caltran; Claude Savornin; Patrick Le Couteur; Paul Jouan; Philippe Deroche; Jean-François Vinceneux; Laurence Barnouin
Journal:  Eur J Orthop Surg Traumatol       Date:  2002-12-17

4.  Number of pegs influence focal stress distributions and micromotion in glenoid implants: a finite element study.

Authors:  Abdul Hadi Abdul Wahab; Mohammed Rafiq Abdul Kadir; Muhammad Noor Harun; Tunku Kamarul; Ardiyansyah Syahrom
Journal:  Med Biol Eng Comput       Date:  2016-06-02       Impact factor: 2.602

5.  Effect of rotator cuff dysfunction on the initial mechanical stability of cementless glenoid components.

Authors:  Daniel R Suárez; Edward R Valstar; Jacqueline C van der Linden; Fred van Keulen; Piet M Rozing
Journal:  Med Biol Eng Comput       Date:  2009-03-21       Impact factor: 2.602

6.  Pro-osteogenic Effects of WNT in a Mouse Model of Bone Formation Around Femoral Implants.

Authors:  Zhijun Li; Xue Yuan; Masaki Arioka; Daniel Bahat; Qiang Sun; Jinlong Chen; Jill A Helms
Journal:  Calcif Tissue Int       Date:  2020-09-29       Impact factor: 4.333

7.  In vivo loading on the hip joint in patients with total hip replacement performing gymnastics and aerobics exercises.

Authors:  Henryk Haffer; Srdan Popovic; Franziska Martin; Sebastian Hardt; Tobias Winkler; Philipp Damm
Journal:  Sci Rep       Date:  2021-06-28       Impact factor: 4.379

8.  Assessment of the primary rotational stability of uncemented hip stems using an analytical model: comparison with finite element analyses.

Authors:  Maria E Zeman; Nicolas Sauwen; Luc Labey; Michiel Mulier; Georges Van der Perre; Siegfried V N Jaecques
Journal:  J Orthop Surg Res       Date:  2008-09-25       Impact factor: 2.359

9.  Contact mechanics of modular metal-on-polyethylene total hip replacement under adverse edge loading conditions.

Authors:  Xijin Hua; Junyan Li; Ling Wang; Zhongmin Jin; Ruth Wilcox; John Fisher
Journal:  J Biomech       Date:  2014-09-01       Impact factor: 2.712

10.  Radiolucencies surrounding acetabular components with three-dimensional coatings: artifact or real?

Authors:  Ahmad Faizan; Philip Chuang; Carlos Aponte; Vincent Moretti; Peter F Sharkey
Journal:  Arthroplast Today       Date:  2017-07-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.