Literature DB >> 9255814

Power vectors: an application of Fourier analysis to the description and statistical analysis of refractive error.

L N Thibos1, W Wheeler, D Horner.   

Abstract

The description of sphero-cylinder lenses is approached from the viewpoint of Fourier analysis of the power profile. It is shown that the familiar sine-squared law leads naturally to a Fourier series representation with exactly three Fourier coefficients, representing the natural parameters of a thin lens. The constant term corresponds to the mean spherical equivalent (MSE) power, whereas the amplitude and phase of the harmonic correspond to the power and axis of a Jackson cross-cylinder (JCC) lens, respectively. Expressing the Fourier series in rectangular form leads to the representation of an arbitrary sphero-cylinder lens as the sum of a spherical lens and two cross-cylinders, one at axis 0 degree and the other at axis 45 degrees. The power of these three component lenses may be interpreted as (x,y,z) coordinates of a vector representation of the power profile. Advantages of this power vector representation of a sphero-cylinder lens for numerical and graphical analysis of optometric data are described for problems involving lens combinations, comparison of different lenses, and the statistical distribution of refractive errors.

Mesh:

Year:  1997        PMID: 9255814     DOI: 10.1097/00006324-199706000-00019

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  223 in total

Review 1.  Astigmatism and the analysis of its surgical correction.

Authors:  N Morlet; D Minassian; J Dart
Journal:  Br J Ophthalmol       Date:  2001-09       Impact factor: 4.638

2.  Evaluation of the measurement of refractive error by the PowerRefractor: a remote, continuous and binocular measurement system of oculomotor function.

Authors:  O A Hunt; J S Wolffsohn; B Gilmartin
Journal:  Br J Ophthalmol       Date:  2003-12       Impact factor: 4.638

3.  Adaptation to astigmatic blur.

Authors:  Lucie Sawides; Susana Marcos; Sowmya Ravikumar; Larry Thibos; Arthur Bradley; Michael Webster
Journal:  J Vis       Date:  2010-10-18       Impact factor: 2.240

4.  Optical treatment of strabismic and combined strabismic-anisometropic amblyopia.

Authors:  Susan A Cotter; Nicole C Foster; Jonathan M Holmes; B Michele Melia; David K Wallace; Michael X Repka; Susanna M Tamkins; Raymond T Kraker; Roy W Beck; Darren L Hoover; Eric R Crouch; Aaron M Miller; Christie L Morse; Donny W Suh
Journal:  Ophthalmology       Date:  2011-09-29       Impact factor: 12.079

5.  Blue Light Protects Against Temporal Frequency Sensitive Refractive Changes.

Authors:  Frances Rucker; Stephanie Britton; Molly Spatcher; Stephan Hanowsky
Journal:  Invest Ophthalmol Vis Sci       Date:  2015-09       Impact factor: 4.799

6.  Monovision slows juvenile myopia progression unilaterally.

Authors:  J R Phillips
Journal:  Br J Ophthalmol       Date:  2005-09       Impact factor: 4.638

7.  Aberrometry Repeatability and Agreement with Autorefraction.

Authors:  Mylan T Nguyen; David A Berntsen
Journal:  Optom Vis Sci       Date:  2017-09       Impact factor: 1.973

8.  Normative best-corrected values of the visual image quality metric VSX as a function of age and pupil size.

Authors:  Gareth D Hastings; Jason D Marsack; Larry N Thibos; Raymond A Applegate
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2018-05-01       Impact factor: 2.129

9.  LogMAR and Stereoacuity in Keratoconus Corrected with Spectacles and Rigid Gas-permeable Contact Lenses.

Authors:  Vinay Kumar Nilagiri; Sangeetha Metlapally; Parthasarathi Kalaiselvan; Clifton M Schor; Shrikant R Bharadwaj
Journal:  Optom Vis Sci       Date:  2018-04       Impact factor: 1.973

10.  Comparison of refractive assessment by wavefront aberrometry, autorefraction, and subjective refraction.

Authors:  Jeffrey R Bennett; Gina M Stalboerger; David O Hodge; Muriel M Schornack
Journal:  J Optom       Date:  2014-12-11
View more