Cytotoxic, allergic and genotoxic activity of a nickel-titanium alloy.

D J Wever1, A G Veldhuizen, M M Sanders, J M Schakenraad, J R van Horn.   

Abstract

The nearly equiatomic nickel-titanium (NiTi) alloy is known for its shape memory properties. These properties can be put to excellent use in various biomedical applications, such as wires for orthodontic tooth alignment and osteosynthesis staples. The aim of this study was to evaluate the short-term biological safety of the NiTi alloy. We carried out an end-point dilution minimal essential medium (MEM) extract cytotoxicity test, a guinea-pig sensitization test and two genotoxicity tests: the Salmonella reverse mutation test and the chromosomal aberration test. The NiTi alloy showed no cytotoxic, allergic or genotoxic activity, similar to the clinical reference control material AISI 316 LVM stainless steel. This promising biological behaviour was most likely due to a minimal release of ions and in that way a reflection of the good corrosion resistance of the NiTi alloy. Given these very good results, together with the good tissue compatibility as shown in several implantation studies in the literature, the NiTi alloy can be regarded as a biologically safe implant material with many promising clinical applications.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9247349     DOI: 10.1016/s0142-9612(97)00041-0

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  29 in total

1.  Biointerface: protein enhanced stem cells binding to implant surface.

Authors:  W Chrzanowski; A Kondyurin; Jae Ho Lee; Megan S Lord; M M M Bilek; Hae-Won Kim
Journal:  J Mater Sci Mater Med       Date:  2012-06-20       Impact factor: 3.896

2.  Effect of ceramic conversion treatments on the surface damage and nickel ion release of NiTi alloys under fretting corrosion conditions.

Authors:  H Dong; X Ju; H Yang; L Qian; Z Zhou
Journal:  J Mater Sci Mater Med       Date:  2007-08-01       Impact factor: 3.896

3.  Surface preparation of bioactive Ni-Ti alloy using alkali, thermal treatments and spark oxidation.

Authors:  W Chrzanowski; E A Abou Neel; D A Armitage; J C Knowles
Journal:  J Mater Sci Mater Med       Date:  2008-01-24       Impact factor: 3.896

4.  Self-Expanding Stent and Delivery System for Aortic Valve Replacement.

Authors:  Dumitru Mazilu; Ming Li; Ozgur Kocaturk; Keith A Horvath
Journal:  J Med Device       Date:  2012-11-01       Impact factor: 0.582

5.  Porous NiTi shape memory alloys produced by SHS: microstructure and biocompatibility in comparison with Ti2Ni and TiNi3.

Authors:  Paola Bassani; Silvia Panseri; Andrea Ruffini; Monica Montesi; Martina Ghetti; Claudio Zanotti; Anna Tampieri; Ausonio Tuissi
Journal:  J Mater Sci Mater Med       Date:  2014-06-14       Impact factor: 3.896

6.  Application of a shape-memory alloy internal fixator for treatment of acetabular fractures with a follow-up of two to nine years in China.

Authors:  Xinwei Liu; Shuogui Xu; Chuncai Zhang; Jiacan Su; Baoqing Yu
Journal:  Int Orthop       Date:  2009-12-11       Impact factor: 3.075

7.  Concept of patient-specific shape memory implants for the treatment of orbital floor fractures.

Authors:  Ronny Grunert; Maximilian Wagner; Christian Rotsch; Harald Essig; Susanna Posern; Friedemann Pabst; Welf-Guntram Drossel; Juergen Lichtenstein
Journal:  Oral Maxillofac Surg       Date:  2017-03-10

8.  Studies on cytotoxic effect of nickel ions on three cultured fibroblasts.

Authors:  M Taira; M S Toguchi; Y Hamada; J Takahashi; R Itou; S Toyosawa; N Ijyuin; M Okazaki
Journal:  J Mater Sci Mater Med       Date:  2001-05       Impact factor: 3.896

9.  Tensile properties and transformation temperatures of Pd added Ti-Ni alloy dental castings.

Authors:  Y Soga; H Doi; T Yoneyama
Journal:  J Mater Sci Mater Med       Date:  2000-11       Impact factor: 3.896

10.  Comparison of the bone modeling effects caused by curved and straight nickel-titanium intramedullary nails.

Authors:  S Kujala; J Tuukkanen; T Jämsä; A Danilov; A Pramila; J Ryhänen
Journal:  J Mater Sci Mater Med       Date:  2002-12       Impact factor: 3.896

View more