Literature DB >> 17665097

Effect of ceramic conversion treatments on the surface damage and nickel ion release of NiTi alloys under fretting corrosion conditions.

H Dong1, X Ju, H Yang, L Qian, Z Zhou.   

Abstract

Recent researches have demonstrated that surface modification can improve the fretting wear resistance of NiTi alloys in air or enhance their aqueous corrosion resistance without fretting. However, little is known about the behaviour of surface engineered NiTi under fretting corrosion conditions. This is important for such body implants as orthodontic arch wires and orthopedic bone fixation devices because they need to withstand the combined attack of corrosion from body fluid and mechanical fretting. In this study, a NiTi alloy was ceramic conversion (CC) treated at 400 and 650 degrees C. The effect of the surface treatment on the fretting corrosion behaviour of NiTi alloy was investigated using fretting corrosion tests in the Ringer's solution. The experimental results have shown that the CC treatment can convert the surface of NiTi into a TiO2 layer, which can effectively improve the fretting corrosion resistance of NiTi alloy and significantly reduce Ni ion release into the Ringer's solution. Detailed SEM observations revealed that the untreated samples were severely damaged by adhesion and delamination; the high temperature (HT) (650 degrees C/1 h) treated samples were damaged mainly by spallation and adhesion; and the low temperature (LT) (400 degrees C/50 h) treated samples were characterised by mild abrasion. Mild oxidation and corrosion were also observed for all three types of samples tested under fretting corrosion conditions.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17665097     DOI: 10.1007/s10856-007-3222-3

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  11 in total

1.  Passivation of nitinol wire for vascular implants--a demonstration of the benefits.

Authors:  B O'Brien; W M Carroll; M J Kelly
Journal:  Biomaterials       Date:  2002-04       Impact factor: 12.479

2.  Increased corrosion resistance of stent materials by converting current surface film of polycrystalline oxide into amorphous oxide.

Authors:  C C Shih; S J Lin; K H Chung; Y L Chen; Y Y Su
Journal:  J Biomed Mater Res       Date:  2000-11

3.  Ion release from NiTi orthodontic wires in artificial saliva with various acidities.

Authors:  Her-Hsiung Huang; Yu-Hui Chiu; Tzu-Hsin Lee; Shih-Ching Wu; Hui-Wen Yang; Kuo-Hsiung Su; Chii-Chih Hsu
Journal:  Biomaterials       Date:  2003-09       Impact factor: 12.479

4.  Surface oxidation of NiTi shape memory alloy.

Authors:  G S Firstov; R G Vitchev; H Kumar; B Blanpain; J Van Humbeeck
Journal:  Biomaterials       Date:  2002-12       Impact factor: 12.479

5.  Surface treatment of NiTi for medical applications.

Authors: 
Journal:  Minim Invasive Ther Allied Technol       Date:  2004-08       Impact factor: 2.442

6.  Effect of modification of oxide layer on NiTi stent corrosion resistance.

Authors:  C Trépanier; M Tabrizian; L H Yahia; L Bilodeau; D L Piron
Journal:  J Biomed Mater Res       Date:  1998

7.  Corrosion behavior of titanium nitride coated Ni-Ti shape memory surgical alloy.

Authors:  D Starosvetsky; I Gotman
Journal:  Biomaterials       Date:  2001-07       Impact factor: 12.479

8.  Cytotoxic, allergic and genotoxic activity of a nickel-titanium alloy.

Authors:  D J Wever; A G Veldhuizen; M M Sanders; J M Schakenraad; J R van Horn
Journal:  Biomaterials       Date:  1997-08       Impact factor: 12.479

Review 9.  Nickel essentiality, toxicity, and carcinogenicity.

Authors:  E Denkhaus; K Salnikow
Journal:  Crit Rev Oncol Hematol       Date:  2002-04       Impact factor: 6.312

10.  Histomorphometric analysis of the response of rat tibiae to shape memory alloy (nitinol).

Authors:  F Takeshita; H Takata; Y Ayukawa; T Suetsugu
Journal:  Biomaterials       Date:  1997-01       Impact factor: 12.479

View more
  2 in total

Review 1.  Micromotions and combined damages at the dental implant/bone interface.

Authors:  Shan-Shan Gao; Ya-Rong Zhang; Zhuo-Li Zhu; Hai-Yang Yu
Journal:  Int J Oral Sci       Date:  2012-12-21       Impact factor: 6.344

2.  Improving the Tribological Properties and Biocompatibility of Zr-Based Bulk Metallic Glass for Potential Biomedical Applications.

Authors:  Victoria Sawyer; Xiao Tao; Huan Dong; Behnam Dashtbozorg; Xiaoying Li; Rachel Sammons; Han-Shan Dong
Journal:  Materials (Basel)       Date:  2020-04-22       Impact factor: 3.623

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.