Literature DB >> 9240980

Anterior cruciate ligament graft fixation. Initial comparison of patellar tendon and semitendinosus autografts in young fresh cadavers.

N J Rowden1, D Sher, G J Rogers, K Schindhelm.   

Abstract

The initial biomechanical properties of semitendinosus and patellar tendon autografts and their fixation strengths were investigated. Twenty fresh cadaveric knees from donors under 42 years of age were used in the study. After removing all soft tissues other than the anterior cruciate ligament, we determined the ultimate tensile strength (2195 +/- 427 N) and stiffness (306 +/- 80 N/mm) of the anterior cruciate ligament in nine knees. In six knees, anterior cruciate ligaments were reconstructed using an autologous patellar tendon graft with proximal and distal interference fit screws; this resulted in an ultimate tensile strength of 416 +/- 66 N. Five knees were reconstructed with quadruple-stranded (double-looped) semitendinosus tendons fixed proximally by a titanium button and braided tape and distally by tibial post screw. This resulted in an ultimate tensile strength of 612 +/- 73 N, which was significantly higher than the strength in the patellar tendon group. Graft stiffness did not differ between the groups and was 47 +/- 19 N/mm (N = 11). This study demonstrates that the reconstructed knees had only 20% to 30% of the ultimate tensile strength of the normal anterior cruciate ligament. In summary, the semitendinosus reconstruction using a button for proximal fixation is, at the time of surgery, approximately 50% stronger than patellar tendon reconstructions with similar stiffness.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9240980     DOI: 10.1177/036354659702500409

Source DB:  PubMed          Journal:  Am J Sports Med        ISSN: 0363-5465            Impact factor:   6.202


  18 in total

1.  Optimal screw diameter for interference fixation in a bone tunnel: a porcine model.

Authors:  M W J Morris; J L Williams; A J Thake; Y Lang; J N Brown
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2004-02-06       Impact factor: 4.342

2.  The load of an implanted graft during and after fixation in anterior cruciate ligament reconstruction.

Authors:  Yukio Yoshihara; Shinichi Yoshiya; Masahiro Kurosaka; Tetsuji Yamamoto; Ryosuke Kuroda; Hirotsugu Muratsu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2004-11-18       Impact factor: 4.342

3.  Equal tension in all four strands of a semitendinosus graft with a low profile tibial fixation device (Cobra LFD).

Authors:  S Winge; P Dunn; B K O Engström
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2005-10-06       Impact factor: 4.342

4.  Second-look arthroscopic findings of 208 patients after ACL reconstruction.

Authors:  Jin Hwan Ahn; Jae Chul Yoo; Hyoung Seop Yang; Jae Hoon Kim; Joon Ho Wang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-10-07       Impact factor: 4.342

5.  The effect of graft choice on functional outcome in anterior cruciate ligament reconstruction.

Authors:  Matjaz Sajovic; Andrej Strahovnik; Radko Komadina; Mojca Z Dernovsek
Journal:  Int Orthop       Date:  2007-03-13       Impact factor: 3.075

6.  Comparative and morphological analysis of commonly used autografts for anterior cruciate ligament reconstruction with the native ACL: an electron, microscopic and morphologic study.

Authors:  Panayiotis T Hadjicostas; Panayotis N Soucacos; Nadezda Koleganova; Gerhard Krohmer; Irina Berger
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-09-27       Impact factor: 4.342

7.  Decrease of knee flexion torque in patients with ACL reconstruction: combined analysis of the architecture and function of the knee flexor muscles.

Authors:  Yukiko Makihara; Akie Nishino; Toru Fukubayashi; Akihiro Kanamori
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2005-10-06       Impact factor: 4.342

Review 8.  Graft fixation alternatives in anterior cruciate ligament reconstruction.

Authors:  Bernardino Saccomanni
Journal:  Musculoskelet Surg       Date:  2011-05-03

9.  Incidence of deep venous thrombosis in Chinese patients undergoing arthroscopic knee surgery for cruciate ligament reconstruction.

Authors:  Jiang-tao Dong; Xin Wang; Xiao-qian Men; Xiao-feng Wang; Xiao-zuo Zheng; Shi-jun Gao
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-11-02       Impact factor: 4.342

10.  A comparison of four tibial-fixation systems in hamstring-graft anterior ligament reconstruction.

Authors:  Henri Robert; Mark Bowen; Guillaume Odry; Michel Collette; Xavier Cassard; Hubert Lanternier; Thierry De Polignac
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-05-10