Literature DB >> 9222398

Optimized Fast-FISH with alpha-satellite probes: acceleration by microwave activation.

M Durm1, F M Haar, M Hausmann, H Ludwig, C Cremer.   

Abstract

It has been shown for several DNA probes that the recently introduced Fast-FISH (fluorescence in situ hybridization) technique is well suited for quantitative microscopy. For highly repetitive DNA probes the hybridization (renaturation) time and the number of subsequent washing steps were reduced considerably by omitting denaturing chemical agents (e.g., formamide). The appropriate hybridization temperature and time allow a clear discrimination between major and minor binding sites by quantitative fluorescence microscopy. The well-defined physical conditions for hybridization permit automatization of the procedure, e.g., by programmable thermal cycler. Here, we present optimized conditions for a commercially available X-specific alpha-satellite probe. Highly fluorescent major binding sites were obtained for 74 degrees C hybridization temperature and 60 min hybridization time. They were clearly discriminated from some low fluorescent minor binding sites on metaphase chromosomes as well as in interphase cell nuclei. On average, a total of 3.43 +/- 1.59 binding sites were measured in metaphase spreads, and 2.69 +/- 1.00 in interphase nuclei. Microwave activation for denaturation and hybridization was tested to accelerate the procedure. The slides with the target material and the hybridization buffer were placed in a standard microwave oven. After denaturation for 20 sec at 900 W, hybridization was performed for 4 min. at 90 W. The suitability of a microwave oven for Fast-FISH was confirmed by the application to a chromosome 1-specific alpha-satellite probe. In this case, denaturation was performed at 630 W for 60 sec and hybridization at 90 W for 5 min. In all cases, the results were analyzed quantitatively and compared to the results obtained by Fast-FISH. The major binding sites were clearly discriminated by their brightness.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9222398     DOI: 10.1590/s0100-879x1997000100003

Source DB:  PubMed          Journal:  Braz J Med Biol Res        ISSN: 0100-879X            Impact factor:   2.590


  3 in total

1.  Rapid identification of pathogens in blood cultures with a modified fluorescence in situ hybridization assay.

Authors:  Remco P H Peters; Michiel A van Agtmael; Alberdina M Simoons-Smit; Sven A Danner; Christina M J E Vandenbroucke-Grauls; Paul H M Savelkoul
Journal:  J Clin Microbiol       Date:  2006-11       Impact factor: 5.948

2.  A simple and rapid fluorescence in situ hybridization microwave protocol for reliable dicentric chromosome analysis.

Authors:  Ian M Cartwright; Matthew D Genet; Takamitsu A Kato
Journal:  J Radiat Res       Date:  2012-11-15       Impact factor: 2.724

3.  FISHing in the microwave: the easy way to preserve proteins. I. Colocalization of DNA probes and surface antigens in human leukocytes.

Authors:  J Gosálvez; J De La Torre; M Pita; A Martinez-Ramirez; C López-Fernandez; V Goyanes; J López-Fernández
Journal:  Chromosome Res       Date:  2002       Impact factor: 4.620

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.