Literature DB >> 9214819

Optimized sampling and parameter estimation for quantification in whole body PET.

K Ho-Shon1, D Feng, R A Hawkins, S Meikle, M J Fulham, X Li.   

Abstract

Whole-body positron emission tomography (PET) has recently emerged as an important imaging tool for cancer detection and staging. Initial applications of the technique have been primarily qualitative. One of the major reasons is the limits imposed by kinetically undersampled data over the whole body, as opposed to the standard method of continuous dynamic sampling in one body location. In this paper, a new estimation method using weighted nonlinear least squares (WNLS) for the first bed position and Bayesian regression (BR) for subsequent positions is proposed. A general criterion for designing optimal sampling schedules which maximizes the measurement information with multiple bed positions is developed. The overall approach is illustrated with the problem of estimating the metabolic rate of glucose (MRGLu) in tumors at different axial positions (image bed positions) in the body by using computer simulations and patient data. The results show that estimates of MRGLu using sparse data and the optimized Bayesian approach are comparable with those obtained by standard methods and fully sampled data. This study demonstrates the potential of the technique described for quantification where several bed positions have to be used to image all the regions of interest (ROI).

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 9214819     DOI: 10.1109/10.536903

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  3 in total

Review 1.  Dynamic whole-body PET imaging: principles, potentials and applications.

Authors:  Arman Rahmim; Martin A Lodge; Nicolas A Karakatsanis; Vladimir Y Panin; Yun Zhou; Alan McMillan; Steve Cho; Habib Zaidi; Michael E Casey; Richard L Wahl
Journal:  Eur J Nucl Med Mol Imaging       Date:  2018-09-29       Impact factor: 9.236

Review 2.  Total-Body PET: Maximizing Sensitivity to Create New Opportunities for Clinical Research and Patient Care.

Authors:  Simon R Cherry; Terry Jones; Joel S Karp; Jinyi Qi; William W Moses; Ramsey D Badawi
Journal:  J Nucl Med       Date:  2017-09-21       Impact factor: 10.057

3.  Dynamic whole-body PET parametric imaging: I. Concept, acquisition protocol optimization and clinical application.

Authors:  Nicolas A Karakatsanis; Martin A Lodge; Abdel K Tahari; Y Zhou; Richard L Wahl; Arman Rahmim
Journal:  Phys Med Biol       Date:  2013-09-30       Impact factor: 3.609

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.