Literature DB >> 9212702

Two-dimensional SEC/RPLC coupled to mass spectrometry for the analysis of peptides.

G J Opiteck1, J W Jorgenson.   

Abstract

A two-dimensional liquid chromatography system is described here which uses size exclusion liquid chromatography (SEC) followed by reversed phase liquid chromatography (RPLC) to separate the mixture of peptides resulting from the enzymatic digestion of a protein. A novel LC/LC interface, using two RPLC columns in parallel rather than storage loops, joins the two chromatographic dimensions. This new interface design permits the use of conventional analytical diameter HPLC columns, 7.8 mm for SEC and 4.6 mm for RPLC, making construction and maintenance of this system very easy. The reversed phase chromatography utilizes 1.5 microns diameter, nonporous C-18 modified silica particles, which produce fast and efficient analyses. Following the high-resolution two-dimensional chromatographic separation, an electrospray mass spectrometer detects the peptide fragments. The mass spectrometer scans a 2000 m/z range to identify the analytes from their molecular weights. The analyses of tryptic digests of ovalbumin and serum albumin are each described.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9212702     DOI: 10.1021/ac961156d

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  25 in total

1.  The human embryonic stem cell proteome revealed by multidimensional fractionation followed by tandem mass spectrometry.

Authors:  Peng Zhao; Thomas C Schulz; Eric S Sherrer; D Brent Weatherly; Allan J Robins; Lance Wells
Journal:  Proteomics       Date:  2014-12-17       Impact factor: 3.984

2.  Factors that affect ion trap data-dependent MS/MS in proteomics.

Authors:  Brett R Wenner; Bert C Lynn
Journal:  J Am Soc Mass Spectrom       Date:  2004-02       Impact factor: 3.109

3.  Exploiting the complementary nature of LC/MALDI/MS/MS and LC/ESI/MS/MS for increased proteome coverage.

Authors:  Wanda M Bodnar; R Kevin Blackburn; Jo M Krise; M Arthur Moseley
Journal:  J Am Soc Mass Spectrom       Date:  2003-09       Impact factor: 3.109

4.  A novel interface for variable flow nanoscale LC/MS/MS for improved proteome coverage.

Authors:  Johannes P C Vissers; R Kevin Blackburn; M Arthur Moseley
Journal:  J Am Soc Mass Spectrom       Date:  2002-07       Impact factor: 3.109

5.  Improved molecular weight-based processing of intact proteins for interrogation by quadrupole-enhanced FT MS/MS.

Authors:  Yi Du; Fanyu Meng; Steven M Patrie; Leah M Miller; Neil L Kelleher
Journal:  J Proteome Res       Date:  2004 Jul-Aug       Impact factor: 4.466

6.  Two-dimensional gas-phase separations coupled to mass spectrometry for analysis of complex mixtures.

Authors:  Keqi Tang; Fumin Li; Alexandre A Shvartsburg; Eric F Strittmatter; Richard D Smith
Journal:  Anal Chem       Date:  2005-10-01       Impact factor: 6.986

7.  An impulse-driven liquid-droplet deposition interface for combining LC with MALDI MS and MS/MS.

Authors:  J Bryce Young; Liang Li
Journal:  J Am Soc Mass Spectrom       Date:  2006-01-27       Impact factor: 3.109

Review 8.  Proteomics and the analysis of proteomic data: an overview of current protein-profiling technologies.

Authors:  Erol E Gulcicek; Christopher M Colangelo; Walter McMurray; Kathryn Stone; Kenneth Williams; Terence Wu; Hongyu Zhao; Heidi Spratt; Alexander Kurosky; Baolin Wu
Journal:  Curr Protoc Bioinformatics       Date:  2005-07

9.  ZIC-cHILIC as a fractionation method for sensitive and powerful shotgun proteomics.

Authors:  Serena Di Palma; Shabaz Mohammed; Albert J R Heck
Journal:  Nat Protoc       Date:  2012-10-25       Impact factor: 13.491

10.  An experimental study of sampling time effects on the resolving power of on-line two-dimensional high performance liquid chromatography.

Authors:  Yuan Huang; Haiwei Gu; Marcelo Filgueira; Peter W Carr
Journal:  J Chromatogr A       Date:  2011-04-12       Impact factor: 4.759

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.