Literature DB >> 21489543

An experimental study of sampling time effects on the resolving power of on-line two-dimensional high performance liquid chromatography.

Yuan Huang1, Haiwei Gu, Marcelo Filgueira, Peter W Carr.   

Abstract

The experimental effects of sampling time on the resolving power of on-line LC×LC were investigated. The first dimension gradient time ((1)t(g)) and sampling time (t(s)) were systematically varied ((1)t(g)=5, 12, 24 and 49 min; t(s)=6, 12, 21 and 40s). The resolving power of on-line LC×LC was evaluated in terms of two metrics namely the numbers of observed peaks and the effective 2D peak capacities obtained in separations of extracts of maize seeds. The maximum effective peak capacity and number of observed peaks of LC×LC were achieved at sampling times between 12 and 21s, at all first dimension gradient times. In addition, both metrics showed that the "crossover" time at which fully optimized 1DLC and LC×LC have equal resolving power varied somewhat with sampling time but is only about 5 min for sampling times of 12 and 21s. The longest crossover time was obtained when the sampling time was 6s. Furthermore, increasing the first dimension gradient time gave large improvements in the resolving power of LC×LC relative to 1DLC. Finally, comparisons of the corrected and effective 2D peak capacities as well as the number of peaks observed showed that the impact of the coverage factor is quite significant.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21489543      PMCID: PMC3132878          DOI: 10.1016/j.chroma.2011.03.032

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  36 in total

1.  Implications of column peak capacity on the separation of complex peptide mixtures in single- and two-dimensional high-performance liquid chromatography.

Authors:  Martin Gilar; Amy E Daly; Marianna Kele; Uwe D Neue; John C Gebler
Journal:  J Chromatogr A       Date:  2004-12-24       Impact factor: 4.759

2.  Calculating optimal modulation periods to maximize the peak capacity in two-dimensional HPLC.

Authors:  Kanta Horie; Hiroshi Kimura; Tohru Ikegami; Akira Iwatsuka; Nabil Saad; Oliver Fiehn; Nobuo Tanaka
Journal:  Anal Chem       Date:  2007-04-17       Impact factor: 6.986

3.  Effect of first-dimension undersampling on effective peak capacity in comprehensive two-dimensional separations.

Authors:  Joe M Davis; Dwight R Stoll; Peter W Carr
Journal:  Anal Chem       Date:  2007-12-13       Impact factor: 6.986

4.  Generation and limitations of peak capacity in online two-dimensional liquid chromatography.

Authors:  Krisztián Horváth; Jacob N Fairchild; Georges Guiochon
Journal:  Anal Chem       Date:  2009-05-15       Impact factor: 6.986

5.  Approaches to comprehensive multidimensional liquid chromatography systems.

Authors:  Jacob N Fairchild; Krisztián Horváth; Georges Guiochon
Journal:  J Chromatogr A       Date:  2008-12-30       Impact factor: 4.759

6.  Theoretical advantages and drawbacks of on-line, multidimensional liquid chromatography using multiple columns operated in parallel.

Authors:  Jacob N Fairchild; Krisztián Horváth; Georges Guiochon
Journal:  J Chromatogr A       Date:  2009-07-07       Impact factor: 4.759

7.  High speed gradient elution reversed phase liquid chromatography of bases in buffered eluents. Part II. Full equilibrium.

Authors:  Adam P Schellinger; Dwight R Stoll; Peter W Carr
Journal:  J Chromatogr A       Date:  2008-02-20       Impact factor: 4.759

8.  Peak capacity optimization in comprehensive two dimensional liquid chromatography: a practical approach.

Authors:  Haiwei Gu; Yuan Huang; Peter W Carr
Journal:  J Chromatogr A       Date:  2010-10-31       Impact factor: 4.759

9.  Equation for peak capacity estimation in two-dimensional liquid chromatography.

Authors:  Xiaoping Li; Dwight R Stoll; Peter W Carr
Journal:  Anal Chem       Date:  2009-01-15       Impact factor: 6.986

10.  Two-dimensional chromatography of complex polymers 6. Method development for (meth)acrylate-based copolymers.

Authors:  Jacques-Antoine Raust; Adele Brüll; Claudine Moire; Céline Farcet; Harald Pasch
Journal:  J Chromatogr A       Date:  2008-07-29       Impact factor: 4.759

View more
  3 in total

1.  Improving peak capacity in fast online comprehensive two-dimensional liquid chromatography with post-first-dimension flow splitting.

Authors:  Marcelo R Filgueira; Yuan Huang; Klaus Witt; Cecilia Castells; Peter W Carr
Journal:  Anal Chem       Date:  2011-11-23       Impact factor: 6.986

2.  Effect of first dimension phase selectivity in online comprehensive two dimensional liquid chromatography (LC×LC).

Authors:  Haiwei Gu; Yuan Huang; Marcelo Filgueira; Peter W Carr
Journal:  J Chromatogr A       Date:  2011-07-24       Impact factor: 4.759

3.  Development of a carbon clad core-shell silica for high speed two-dimensional liquid chromatography.

Authors:  Changyub Paek; Yuan Huang; Marcelo R Filgueira; Alon V McCormick; Peter W Carr
Journal:  J Chromatogr A       Date:  2012-01-11       Impact factor: 4.759

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.