Literature DB >> 9203099

The effect of surface roughness on early in vivo plaque colonization on titanium.

L Rimondini1, S Farè, E Brambilla, A Felloni, C Consonni, F Brossa, A Carrassi.   

Abstract

THE STUDY ASSESSES IN VIVO the surface roughness necessary to reduce plaque colonization on titanium after 24 hours. Three groups of 16 titanium disks were assigned to 3 different polishing groups (A, B, and C). The roughness was evaluated with a laser profilometer and the morphology with a scanning electron microscope (SEM). Eight volunteers were enrolled and two stents were applied in the mandibular posterior region of each. Each stent supported 3 disks, one per group. The volunteers suspended oral hygiene for 24 hours, after which the stents were removed; one was processed for evaluation of the adherent biomass and the other for SEM study. On each specimen a global area of 100 x 125 microns was examined with SEM. The area was composed of five 20 x 25 microns randomly selected fields. For each field the density of bacteria and the morphotypes were recorded. The data quoted for the global area are cumulative of those observed in the 20 x 25 microns fields. Group A had a significantly smoother surface than groups B and C. The adherent microbial biomass determination and SEM evaluation revealed that group A contained less bacteria than the roughest group. The bacterial population was composed of cocci in group A, and of cocci and short and long rods in groups B and C. We conclude that a titanium surface with Ra < or = 0.088 microns and Rz < or = 1.027 microns strongly inhibits accumulation and maturation of plaque at the 24-hour time period and that such smoothness can be achieved in transgingival and healing implant components.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9203099     DOI: 10.1902/jop.1997.68.6.556

Source DB:  PubMed          Journal:  J Periodontol        ISSN: 0022-3492            Impact factor:   6.993


  36 in total

1.  The effect of Er:YAG laser irradiation on the scanning electron microscopic structure and surface roughness of various implant surfaces: an in vitro study.

Authors:  Seung-Il Shin; Hyung-Ki Min; Bo-Hyun Park; Young-Hyuk Kwon; Joon-Bong Park; Yeek Herr; Seong-Joo Heo; Jong-Hyuk Chung
Journal:  Lasers Med Sci       Date:  2010-08-06       Impact factor: 3.161

2.  Effectivity of air-abrasive powder based on glycine and tricalcium phosphate in removal of initial biofilm on titanium and zirconium oxide surfaces in an ex vivo model.

Authors:  Gordon John; Jürgen Becker; Frank Schwarz
Journal:  Clin Oral Investig       Date:  2015-08-29       Impact factor: 3.573

3.  Influence of different treatment approaches on the removal of early plaque biofilms and the viability of SAOS2 osteoblasts grown on titanium implants.

Authors:  Frank Schwarz; Anton Sculean; Georg Romanos; Monika Herten; Nadine Horn; Werner Scherbaum; Jürgen Becker
Journal:  Clin Oral Investig       Date:  2005-04-20       Impact factor: 3.573

4.  Effects of hydrophilicity and microtopography of titanium implant surfaces on initial supragingival plaque biofilm formation. A pilot study.

Authors:  F Schwarz; A Sculean; M Wieland; N Horn; E Nuesry; C Bube; J Becker
Journal:  Mund Kiefer Gesichtschir       Date:  2007-12

5.  Efficacy of various side-to-side toothbrushes for noncontact biofilm removal.

Authors:  Julia C Schmidt; Monika Astasov-Frauenhoffer; Irmgard Hauser-Gerspach; Jan-Philipp Schmidt; Tuomas Waltimo; Roland Weiger; Clemens Walter
Journal:  Clin Oral Investig       Date:  2013-07-20       Impact factor: 3.573

6.  The role of macrophage polarization on fibroblast behavior-an in vitro investigation on titanium surfaces.

Authors:  Xuzhu Wang; Yulan Wang; Dieter D Bosshardt; Richard J Miron; Yufeng Zhang
Journal:  Clin Oral Investig       Date:  2017-07-14       Impact factor: 3.573

7.  Biomimetic coatings and negative pressure wound therapy independently limit epithelial downgrowth around percutaneous devices.

Authors:  Sujee Jeyapalina; Saranne J Mitchell; Jayant Agarwal; Kent N Bachus
Journal:  J Mater Sci Mater Med       Date:  2019-06-10       Impact factor: 3.896

8.  Taurolidine as an effective and biocompatible additive for plaque-removing techniques on implant surfaces.

Authors:  Gordon John; Frank Schwarz; Jürgen Becker
Journal:  Clin Oral Investig       Date:  2014-10-28       Impact factor: 3.573

9.  Histological and immunohistochemical evaluation of the peri-implant soft tissues around machined and acid-etched titanium healing abutments: a prospective randomised study.

Authors:  Marco Degidi; Luciano Artese; Adriano Piattelli; Antonio Scarano; Jamil A Shibli; Marcello Piccirilli; Vittoria Perrotti; Giovanna Iezzi
Journal:  Clin Oral Investig       Date:  2011-06-08       Impact factor: 3.573

10.  In vitro adhesion of Streptococcus sanguinis to dentine root surface after treatment with Er:YAG laser, ultrasonic system, or manual curette.

Authors:  Claudia Ota-Tsuzuki; Fernanda L Martins; Ana Paula O Giorgetti; Patrícia M de Freitas; Poliana M Duarte
Journal:  Photomed Laser Surg       Date:  2009-10       Impact factor: 2.796

View more