Literature DB >> 9196422

Transcatheter umbrella closure of aorto-pulmonary window.

R M Tulloh1, M L Rigby.   

Abstract

Aorto-pulmonary window (aorto-pulmonary septal defect) is an uncommon congenital cardiac malformation which is repaired using cardiopulmonary bypass. A case is described of an infant with a small aorto-pulmonary window which was closed by transcatheter insertion of a double umbrella device. Complete occlusion of the defect was achieved without complications. Transcatheter umbrella closure of a small aorto-pulmonary window is feasible in infancy and the technique is likely to be applicable in a few cases.

Entities:  

Mesh:

Year:  1997        PMID: 9196422      PMCID: PMC484774          DOI: 10.1136/hrt.77.5.479

Source DB:  PubMed          Journal:  Heart        ISSN: 1355-6037            Impact factor:   5.994


  9 in total

1.  Aorticopulmonary septal defect: diagnosis and surgical treatment.

Authors:  D A COOLEY; D G MCNAMARA; J R LATSON
Journal:  Surgery       Date:  1957-07       Impact factor: 3.982

2.  Front-loading of double-umbrella devices, a new technique for umbrella delivery for closing cardiovascular defects.

Authors:  S B Perry; J E Lock
Journal:  Am J Cardiol       Date:  1992-10-01       Impact factor: 2.778

3.  Aorticopulmonary septal defect.

Authors:  H N NEUFELD; R G LESTER; P ADAMS; R C ANDERSON; C W LILLEHEI; J E EDWARDS
Journal:  Am J Cardiol       Date:  1962-01       Impact factor: 2.778

4.  Surgical closure of an aortic septal defect.

Authors:  R E GROSS
Journal:  Circulation       Date:  1952-06       Impact factor: 29.690

5.  Aortopulmonary window.

Authors:  P B Deverall; J C Lincoln; E Aberdeen; R E Bonham-Carter; D J Waterston
Journal:  J Thorac Cardiovasc Surg       Date:  1969-04       Impact factor: 5.209

6.  Transcatheter closure of an aortopulmonary window with a modified double umbrella occluder system.

Authors:  T Stamato; L N Benson; J F Smallhorn; R M Freedom
Journal:  Cathet Cardiovasc Diagn       Date:  1995-06

7.  Anomalous origin of the right coronary artery with aortopulmonary window: functional and surgical considerations.

Authors:  S V Luisi; M H Ashraf; G Gula; R Radley-Smith; M Yacoub
Journal:  Thorax       Date:  1980-06       Impact factor: 9.139

8.  Primary transcatheter umbrella closure of perimembranous ventricular septal defect.

Authors:  M L Rigby; A N Redington
Journal:  Br Heart J       Date:  1994-10

9.  Umbrella occlusion of persistent arterial duct in children under two years.

Authors:  M A Gatzoulis; M L Rigby; A N Redington
Journal:  Br Heart J       Date:  1994-10
  9 in total
  7 in total

1.  Aortopulmonary septal defect with interrupted aortic arch in a monochorionic diamniotic twin pregnancy.

Authors:  Aytul Corbacioglu Esmer; Ahmet Gul; Hediye Dagdeviren; Isil Turan Bakirci
Journal:  J Med Ultrason (2001)       Date:  2012-05-03       Impact factor: 1.314

2.  Transcatheter closure of a residual aortopulmonary window through internal jugular vein access.

Authors:  R Prem Sekar; P R Bhima Shankar; Kotturathu Mamman Cherian
Journal:  Indian Heart J       Date:  2012-07-27

3.  Unconventional uses of septal occluder devices: Our experience reviewed.

Authors:  Neeraj Awasthy; Munesh Tomar; S Radhakrishnan; Savitri Shrivastava
Journal:  Indian Heart J       Date:  2015-05-14

4.  Transcatheter closure of symptomatic aortopulmonary window in an infant.

Authors:  F Pillekamp; T Hannes; D Koch; K Brockmeier; N Sreeram
Journal:  Images Paediatr Cardiol       Date:  2008-04

5.  Transesophageal Echocardiography in a Distal Aortopulmonary Window.

Authors:  Subramanian Chellappan; Ashish Katewa; Yogesh C Sathe
Journal:  J Cardiovasc Echogr       Date:  2016 Oct-Dec

6.  Percutaneous closure of an aortopulmonary window in a young adult patient: a case report of transcatheter closure with an occluder device.

Authors:  Mario Giordano; Gianfranco Butera
Journal:  Eur Heart J Case Rep       Date:  2020-04-04

7.  Aortopulmonary window in infants.

Authors:  Mehdi Ghaderian
Journal:  Heart Views       Date:  2012-07
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.