Literature DB >> 23102395

Transcatheter closure of a residual aortopulmonary window through internal jugular vein access.

R Prem Sekar1, P R Bhima Shankar, Kotturathu Mamman Cherian.   

Abstract

The use of Amplatzer septal occluder for closing a residual aortopulmonary defect has been described. This is usually performed by femoral access. We report closure of a residual aortopulmonary defect using right internal jugular vein access in a patient who had no femoral access as a result of previous cannulation for surgical repair. The 1 cm defect was closed successfully using a 10 mm Amplatzer septal occluder. Technical difficulty anticipated was unfounded although it was more cumbersome than femoral access. Left to right cardiac defects including PDA and AP window are amenable to transcatheter closure through internal jugular vein access.
Copyright © 2012 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23102395      PMCID: PMC3861093          DOI: 10.1016/j.ihj.2012.07.018

Source DB:  PubMed          Journal:  Indian Heart J        ISSN: 0019-4832


  6 in total

1.  Amplatzer device closure of a residual aortopulmonary window.

Authors:  T Richens; N Wilson
Journal:  Catheter Cardiovasc Interv       Date:  2000-08       Impact factor: 2.692

2.  Closure of aortopulmonary window with amplatzer duct occluder device.

Authors:  M Atiq; N Rashid; K A Kazmi; S A Qureshi
Journal:  Pediatr Cardiol       Date:  2003-04-14       Impact factor: 1.655

3.  Percutaneous transcatheter patent foramen ovale closure using the right internal jugular venous approach.

Authors:  Mark A Sader; Michael De Moor; Eugene Pomerantsev; Igor F Palacios
Journal:  Catheter Cardiovasc Interv       Date:  2003-12       Impact factor: 2.692

4.  Transcatheter closure of aortopulmonary window using Amplatzer device.

Authors:  Guruprasad D Naik; V Subash Chandra; Anand Shenoy; B C Isaac; G G Shetty; P Padmakumar; M Jayranganath
Journal:  Catheter Cardiovasc Interv       Date:  2003-07       Impact factor: 2.692

5.  Transcatheter umbrella closure of aorto-pulmonary window.

Authors:  R M Tulloh; M L Rigby
Journal:  Heart       Date:  1997-05       Impact factor: 5.994

6.  Transcatheter closure of an aortopulmonary window with a modified double umbrella occluder system.

Authors:  T Stamato; L N Benson; J F Smallhorn; R M Freedom
Journal:  Cathet Cardiovasc Diagn       Date:  1995-06
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.