Literature DB >> 26071291

Unconventional uses of septal occluder devices: Our experience reviewed.

Neeraj Awasthy1, Munesh Tomar2, S Radhakrishnan3, Savitri Shrivastava4.   

Abstract

UNLABELLED: Device closure is now an accepted modality of treatment for cardiac septal defects such as fossa ovalis Atrial Septal Defect (ASD), Ventricular Septal Defect (VSD) and Patent Ductus Arteriosus (PDA) and have well-accepted indication and long term results. Devices used for these defects have been specifically designed for use in closing these defects. In this manuscript, we are reporting the efficacy of closure of nonseptal defects with devices conventionally used for septal cardiac defects although they have not been prototyped for use in such conditions. AIM: To study use of occluder devices in nonseptal defects/malformation. MATERIAL &
METHODS: 39 patients, in the age group 2-67 yrs, were treated percutaneously with occluder devices for various conditions. These included: coronary arteriovenous (CAV) fistula (n = 6), pulmonary AV fistula (n = 4), systemic AV fistula (vascular plug; n = 1), closure of AP window (duct occluder; n = 3), closure of ascending aorta perforation (septal occluder; n = 2), ruptured sinus of Valsalva (RSOV) (duct occluder; n = 13), Fontan fenestration closure (ASD septal occluder, patent foramen ovale device, vascular plug n = 3,1 each), splenic artery (duct occluder; n = 1), Balock Taussig shunt (duct occlude; n = 1)and closure of mitral paravalvular leak (n = 3; duct occlude devices = 2, VSD device: n = 1) and aortic paravalvular leak n = 2 (duct occluder; n = 2 additional vascular plug = 2).
RESULTS: Procedural success: Successful closure as signified by no residual shunt was achieved in all coronary AV fistula (immediately n = 2, at 3 months in all), ruptured sinus of Valsalva (immediate in all), fenestrated Fontan (immediately in all), and ascending aorta perforations (immediate), mitral paravalvular leak (immediate in none, and late in 2/3). The aortic paravalvular leak closed at 3 months follow-up in one and small residual persisted after 1 month in another. COMPLICATIONS: Local site Hematoma was observed in 4 patients. 2 of them required post procedure transfusion for the same. Hematuria was observed in 2 of the 4 patients of mitral paravalvular leak and 2 patients of RSOV device closure. Hematuria subsided with conservative management before discharge from hospital in all the 4 cases. One patient with residual mitral regurgitation required surgical management for continuing hematuria, anemia and hyperbilirubenemia. There was one mortality observed on table during the attempted closure of a very large RSOV who presented to us in severe congestive heart failure and shock. On follow up ranging from 2 months to 6 years, all the patients are asymptomatic. There was no late complication related to device in any patient.
CONCLUSION: It is feasible in selected nonseptal defects, which traditionally have been subjected to surgical interventions, to treat successfully, non surgically with the use of non prototype occluder devices without significant complications. Conventionally these devices have not been recommended for closure of nonseptal defects but show good early outcome. Adequate sample size with good follow up data is necessary before concluding that it can be safe alternative to surgery on long term.
Copyright © 2015 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Atrial septal occluder; Coronary AV fistulae closure; Duct occluder; Paravalvular leak closure; RSOV closure; Septal occluder devices

Mesh:

Year:  2015        PMID: 26071291      PMCID: PMC4475847          DOI: 10.1016/j.ihj.2015.02.028

Source DB:  PubMed          Journal:  Indian Heart J        ISSN: 0019-4832


  34 in total

1.  Transcatheter closure of extracardiac fontan fenestration in a cyanotic patient.

Authors:  Fikri Demir; Tevfik Karagöz; Ebru Aypar; Semra Atalay; Ercan Tutar
Journal:  Turk J Pediatr       Date:  2010 Jul-Aug       Impact factor: 0.552

2.  Successful transcatheter closure with the buttoned device of aortopulmonary window in an adult.

Authors:  S B Jureidini; J J Spadaro; P S Rao
Journal:  Am J Cardiol       Date:  1998-02-01       Impact factor: 2.778

3.  Successful occlusion of a coronary arteriovenous fistula using an Amplatzer duct occluder.

Authors:  M Sadiq; J L Wilkinson; S A Qureshi
Journal:  Cardiol Young       Date:  2001-01       Impact factor: 1.093

4.  Transcatheter closure of an aortopulmonary window with a modified double umbrella occluder system.

Authors:  T Stamato; L N Benson; J F Smallhorn; R M Freedom
Journal:  Cathet Cardiovasc Diagn       Date:  1995-06

5.  Percutaneous closure of a ruptured sinus of Valsalva aneurysm using the Amplatzer Duct Occluder.

Authors:  Savitri Fedson; Neeraj Jolly; Roberto M Lang; Ziyad M Hijazi
Journal:  Catheter Cardiovasc Interv       Date:  2003-03       Impact factor: 2.692

6.  Transcatheter umbrella closure of valvular and paravalvular leaks.

Authors:  M Hourihan; S B Perry; V S Mandell; J F Keane; J J Rome; J A Bittl; J E Lock
Journal:  J Am Coll Cardiol       Date:  1992-11-15       Impact factor: 24.094

7.  Dual use of an amplatzer device in the transcatheter embolization of a large high-flow renal arteriovenous fistula.

Authors:  Oluwatoyin Idowu; Fayyaz Barodawala; Alexander Nemeth; Scott O Trerotola
Journal:  J Vasc Interv Radiol       Date:  2007-05       Impact factor: 3.464

8.  Transcatheter closure of ruptured sinus of valsalva aneurysm.

Authors:  Ramesh Arora; Vijay Trehan; Uma Mahesh C Rangasetty; Saibal Mukhopadhyay; Ashish K Thakur; G S Kalra
Journal:  J Interv Cardiol       Date:  2004-02       Impact factor: 2.279

9.  Percutaneous closure of a complex prosthetic mitral paravalvular leak using transesophageal echocardiographic guidance.

Authors:  Gordon Pate; John Webb; Christopher Thompson; Brad Munt; Sanjay Chugh; Ron Carere; Robert Moss
Journal:  Can J Cardiol       Date:  2004-03-15       Impact factor: 5.223

10.  Transcatheter occlusion of ruptured sinus of valsalva aneurysm: innovative use of available technology.

Authors:  P Syamasundar Rao; Burt I Bromberg; Saadeh B Jureidini; Andrew C Fiore
Journal:  Catheter Cardiovasc Interv       Date:  2003-01       Impact factor: 2.692

View more
  3 in total

1.  Clinical Use of the Amplatzer Device in the Management of Intracardiac Defects: A Single-Center Experience.

Authors:  Seema S Rao; Tyler L Scaff; John Gurley; Sibu Saha
Journal:  Int J Angiol       Date:  2018-01-30

2.  Late Bacterial Endocarditis in an Intravenous Drug User With an Amplatzer Septal Occluder.

Authors:  Michael S La Sala; Hajir Zohourian; Joseph McKeown; Samuel Snyder
Journal:  Tex Heart Inst J       Date:  2020-08-01

3.  Transcatheter closure of complex iatrogenic ventricular septal defect: a case report.

Authors:  Alberto Barioli; Francesco Cardaioli; Andrea Pavei; Giuseppe Tarantini
Journal:  Eur Heart J Case Rep       Date:  2020-06-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.