Measurement of polyethylene wear in cementless total hip arthroplasty.

C H Shih1, P C Lee, J H Chen, C L Tai, L F Chen, J S Wu, W H Chang.   

Abstract

We made a clinical study of polyethylene wear in 240 hips of 187 patients having primary total hip arthroplasties from 1989 to 1990, using uncemented Osteonics components, with a head size of 26 mm. We excluded cups with anteversion of over 20 degrees and measured linear wear by a new method using a digitiser and special software of our design. Follow-up was from two to five years (mean 4.3). The mean age at operation was 50.3 years, with more men than women (1.4:1). The mean linear wear per year was 0.15 mm; this did not increase with the longevity of the prosthesis (p = 0.54). In 59 hips showing evidence of osteolysis, the mean linear wear rate was significantly higher at 0.23 mm/year (p <0.001). The mean linear wear rate also correlated significantly with age at the time of operation (p = 0.008), but we found no significant correlations with body-weight, gender, aetiology of the disease, thickness of polyethylene, or cup position. Our new method of measurement is time-saving and reproducible. The results confirm the greater rate of linear wear of polyethylene in patients showing osteolysis and in those who are younger.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9180309     DOI: 10.1302/0301-620x.79b3.6630

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  10 in total

1.  Wear analysis of chamfered elongated acetabular cup liners.

Authors:  Hsiao-Che Lin; Tzuo-Liang Luo; Jian-Horng Chen
Journal:  Med Biol Eng Comput       Date:  2011-12-22       Impact factor: 2.602

2.  Wear patterns of, and wear volume formulae for, cylindrically elongated acetabular cup liners.

Authors:  James Shih-Shyn Wu; Shu-Ling Hsu; Jian-Horng Chen
Journal:  Med Biol Eng Comput       Date:  2010-04-28       Impact factor: 2.602

3.  Early polyethylene wear and osteolysis with ABG acetabular cups (7- to 12-year follow-up).

Authors:  Sachin Badhe; Peter Livesley
Journal:  Int Orthop       Date:  2005-11-08       Impact factor: 3.075

4.  Eleven-year results of the ABG I hip replacement.

Authors:  W Y Kim; B N Muddu
Journal:  Int Orthop       Date:  2006-03-07       Impact factor: 3.075

5.  Evaluating the accuracy of wear formulae for acetabular cup liners.

Authors:  James Shih-Shyn Wu; Shu-Ling Hsu; Jian-Horng Chen
Journal:  Med Biol Eng Comput       Date:  2009-10-10       Impact factor: 2.602

6.  THA with highly cross-linked polyethylene in patients 50 years or younger.

Authors:  Derek S Shia; John C Clohisy; Mark F Schinsky; John M Martell; William J Maloney
Journal:  Clin Orthop Relat Res       Date:  2009-01-14       Impact factor: 4.176

7.  Uncemented total hip arthroplasty in chronic hemodialysis patients.

Authors:  Wei-Chun Li; Chun-Hsiung Shih; Steve W Ueng; Hsin-Nung Shih; Mel S Lee; Pang-Hsin Hsieh
Journal:  Acta Orthop       Date:  2010-04       Impact factor: 3.717

8.  Cross-linked compared with historical polyethylene in THA: an 8-year clinical study.

Authors:  Carel H Geerdink; Bernd Grimm; Wendy Vencken; Ide C Heyligers; Alphons J Tonino
Journal:  Clin Orthop Relat Res       Date:  2008-11-22       Impact factor: 4.176

9.  A comparison of polyethylene wear between cobalt-chrome ball heads and alumina ball heads after total hip arthroplasty: a 10-year follow-up.

Authors:  Shijun Wang; ShuDong Zhang; YuChi Zhao
Journal:  J Orthop Surg Res       Date:  2013-07-08       Impact factor: 2.359

10.  Cementless total hip replacement: past, present, and future.

Authors:  Harumoto Yamada; Yasuo Yoshihara; Osamu Henmi; Mitsuhiro Morita; Yuichiro Shiromoto; Tomoki Kawano; Arihiko Kanaji; Kennichi Ando; Masato Nakagawa; Naoto Kosaki; Eiichi Fukaya
Journal:  J Orthop Sci       Date:  2009-04-01       Impact factor: 1.601

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.