Leakage of fluid past the tracheal tube cuff in a benchtop model.

P J Young1, M Rollinson, G Downward, S Henderson.   

Abstract

We have assessed a range of high volume, low pressure (HVLP) cuffed tracheal tubes in a benchtop model, for leakage of fluid from above the cuff to the model trachea below, during various ventilatory modes. Rapid leakage occurred in the model during all modes of ventilation, unless tracheal pressure was greater than the height of fluid in the column above the cuff. This leakage occurred preferentially down longitudinal folds that occur in the HVLP cuff wall. This model suggests that, if a longitudinal fold within the cuff wall is patent, then the possibility exists of subglottic to tracheal leakage.

Mesh:

Year:  1997        PMID: 9175972     DOI: 10.1093/bja/78.5.557

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  34 in total

1.  Intratracheal long-term pH monitoring: a new method to evaluate episodes of silent acid aspiration in patients after esophagectomy and gastric pull up.

Authors:  Werner K H Kauer; Hubert J Stein; Holger Bartels; J Rüdiger Siewert
Journal:  J Gastrointest Surg       Date:  2003 Jul-Aug       Impact factor: 3.452

2.  Fluid leakage past tracheal tube cuffs: evaluation of the new Microcuff endotracheal tube.

Authors:  Alexander Dullenkopf; Andreas Gerber; Markus Weiss
Journal:  Intensive Care Med       Date:  2003-08-16       Impact factor: 17.440

3.  Endotracheal tube cuff--small important part of a big issue.

Authors:  Shai Efrati; Israel Deutsch; Gabriel M Gurman
Journal:  J Clin Monit Comput       Date:  2012-01-03       Impact factor: 2.502

4.  Variables affecting leakage past endotracheal tube cuffs: a bench study.

Authors:  Renée Pitts; Daniel Fisher; Demet Sulemanji; Joseph Kratohvil; Yandong Jiang; Robert Kacmarek
Journal:  Intensive Care Med       Date:  2010-09-18       Impact factor: 17.440

5.  Fluid leakage across tracheal tube cuff, effect of different cuff material, shape, and positive expiratory pressure: a bench-top study.

Authors:  Alberto Zanella; Vittorio Scaravilli; Stefano Isgrò; Manuela Milan; Massimo Cressoni; Nicolò Patroniti; Roberto Fumagalli; Antonio Pesenti
Journal:  Intensive Care Med       Date:  2010-12-09       Impact factor: 17.440

6.  Leakage of fluid in different types of tracheal tubes.

Authors:  U Winklmaier; K Wüst; S Schiller; F Wallner
Journal:  Dysphagia       Date:  2006-10       Impact factor: 3.438

7.  Oral care reduces incidence of ventilator-associated pneumonia in ICU populations.

Authors:  Hideo Mori; Hiroyuki Hirasawa; Shigeto Oda; Hidetoshi Shiga; Kenichi Matsuda; Masataka Nakamura
Journal:  Intensive Care Med       Date:  2006-01-25       Impact factor: 17.440

8.  Mechanical influences on fluid leakage past the tracheal tube cuff in a benchtop model.

Authors:  Islem Ouanes; Aissam Lyazidi; Pierre Eric Danin; Nerlep Rana; Annalisa Di Bari; Fekri Abroug; Bruno Louis; Laurent Brochard
Journal:  Intensive Care Med       Date:  2011-02-12       Impact factor: 17.440

9.  Tracheal fluid leakage in benchtop trials: comparison of static versus dynamic ventilation model with and without lubrication.

Authors:  Mital H Dave; Nelly Koepfer; Caveh Madjdpour; Angela Frotzler; Markus Weiss
Journal:  J Anesth       Date:  2010-02-23       Impact factor: 2.078

Review 10.  Technologic advances in endotracheal tubes for prevention of ventilator-associated pneumonia.

Authors:  Juan F Fernandez; Stephanie M Levine; Marcos I Restrepo
Journal:  Chest       Date:  2012-07       Impact factor: 9.410