Leakage of fluid in different types of tracheal tubes.

U Winklmaier1, K Wüst, S Schiller, F Wallner.   

Abstract

The aim of this study was to evaluate leakage of liquids, i.e., water and saliva, past low-pressure cuffs of tracheostomy tubes. Three different types of tracheostomy tubes, TRACOE vario (TRACOE Medical GmbH, Germany), Rüsch Ultra-Tracheoflex (Rüsch GmbH, Germany), and Portex Blue Line Ultra (Smiths Medical, UK) were tested in isolated pig tracheas. Sixty samples (10 tubes each of 7- and 8-mm inner diameter of each type) were used. Four different experiments were devised: type 1 (water and artificial ventilation), type 2 (water and no artificial ventilation), type 3 (saliva and artificial ventilation), and type 4 (saliva and no artificial ventilation). Six milliliters of water or artificial saliva were infused over the cuff and the volume of fluid that leaked past the cuff was measured after 5, 10, and 15 min. Intracuff pressure was also measured three times. The saliva experiments resulted in less leakage than the water experiments. Leakage after treatment with water or artificial saliva is higher without artificial ventilation than with ventilation. The amount of leakage among the tubes with respect to manufacturer showed statistically significant results. However, there were no differences among tracheostomy tubes with respect to internal diameter.

Entities:  

Mesh:

Year:  2006        PMID: 17203331     DOI: 10.1007/s00455-006-9047-2

Source DB:  PubMed          Journal:  Dysphagia        ISSN: 0179-051X            Impact factor:   3.438


  14 in total

1.  Tracheal cuff pressure--a survey of clinical practice.

Authors:  S Sathishkumar; P Young
Journal:  Br J Anaesth       Date:  2002-03       Impact factor: 9.166

2.  Fluid leakage past tracheal tube cuffs: evaluation of the new Microcuff endotracheal tube.

Authors:  Alexander Dullenkopf; Andreas Gerber; Markus Weiss
Journal:  Intensive Care Med       Date:  2003-08-16       Impact factor: 17.440

3.  Endotracheal tube cuff pressure assessment: pitfalls of finger estimation and need for objective measurement.

Authors:  R Fernandez; L Blanch; J Mancebo; N Bonsoms; A Artigas
Journal:  Crit Care Med       Date:  1990-12       Impact factor: 7.598

4.  Effect of the Passy-Muir Valve on aspiration in patients with tracheostomy.

Authors:  M A Dettelbach; R D Gross; J Mahlmann; D E Eibling
Journal:  Head Neck       Date:  1995 Jul-Aug       Impact factor: 3.147

5.  Leakage of fluid around low-pressure tracheal tube cuffs.

Authors:  M Oikkonen; U Aromaa
Journal:  Anaesthesia       Date:  1997-06       Impact factor: 6.955

6.  Leakage of fluid past the tracheal tube cuff in a benchtop model.

Authors:  P J Young; M Rollinson; G Downward; S Henderson
Journal:  Br J Anaesth       Date:  1997-05       Impact factor: 9.166

7.  Aspiration in patients with tracheostomies.

Authors:  J L Cameron; J Reynolds; G D Zuidema
Journal:  Surg Gynecol Obstet       Date:  1973-01

8.  Compliance characteristics of the Portex Soft Seal Cuff improves seal against leakage of fluid in a pig trachea model.

Authors:  P J Young; M C Blunt
Journal:  Crit Care       Date:  1999-08-31       Impact factor: 9.097

9.  Dimensions of the normal human trachea.

Authors:  E Breatnach; G C Abbott; R G Fraser
Journal:  AJR Am J Roentgenol       Date:  1984-05       Impact factor: 3.959

10.  Swallowing dysfunction in patients receiving prolonged mechanical ventilation.

Authors:  K Tolep; C L Getch; G J Criner
Journal:  Chest       Date:  1996-01       Impact factor: 9.410

View more
  1 in total

1.  Accuracy of alpha amylase in diagnosing microaspiration in intubated critically-ill patients.

Authors:  Florent Dewavrin; Farid Zerimech; Alexandre Boyer; Patrice Maboudou; Malika Balduyck; Alain Duhamel; Saad Nseir
Journal:  PLoS One       Date:  2014-03-06       Impact factor: 3.240

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.