Radiation exposure during standard and complex interventional procedures.

T Vehmas1.   

Abstract

Radiation doses given during standard and complex interventional procedures were compared. Screening times, dose-area products, and radiologists' forehead and finger doses were recorded during 28 standard percutaneous drainages and 10 complex drainages (eight combined procedures and two failed procedures). The median screening times (8.75 min) and finger doses (84 microGy) during standard drainages were less than those during complex drainages (20.5 min, p = 0.0005 and 163 microGy, p = 0.0003). Dose-area products and forehead doses were also lower, but not significantly. Previously published series on radiation measurements lack data on complex procedures. This may bias the results, since combined and failed interventions, which are common, are associated with higher radiation exposure than are standard procedures.

Mesh:

Year:  1997        PMID: 9166055     DOI: 10.1259/bjr.70.831.9166055

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  7 in total

Review 1.  Personal dosimetry for interventional operators: when and how should monitoring be done?

Authors:  C J Martin
Journal:  Br J Radiol       Date:  2010-12-15       Impact factor: 3.039

2.  Reference levels for patient radiation doses in interventional radiology: proposed initial values for U.S. practice.

Authors:  Donald L Miller; Deukwoo Kwon; Grant H Bonavia
Journal:  Radiology       Date:  2009-09-29       Impact factor: 11.105

3.  Radiation peak skin dose to risk stratify electrophysiological procedures for deterministic skin damage.

Authors:  J R Paisey; A M Yue; A White; A Moss; J M Morgan; P R Roberts
Journal:  Int J Cardiovasc Imaging       Date:  2004-08       Impact factor: 2.357

Review 4.  Cancer in veterinarians.

Authors:  L Fritschi
Journal:  Occup Environ Med       Date:  2000-05       Impact factor: 4.402

5.  The contribution of interventional cardiology procedures to the population radiation dose in a 'health-care level I' representative region.

Authors:  Andrea Peruzzo Cornetto; Stefania Aimonetto; Francesco Pisano; Marcello Giudice; Marco Sicuro; Teodoro Meloni; Santi Tofani
Journal:  Radiat Prot Dosimetry       Date:  2015-05-25       Impact factor: 0.972

6.  Patient radiation dose audits for fluoroscopically guided interventional procedures.

Authors:  Stephen Baiter; Marvin Rosenstein; Donald L Miller; Beth Schueler; David Spelic
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

7.  Evaluation of operator radioprotection using a new injection device during vertebroplasty.

Authors:  L Nguyen-Kim; C Fargeot; H Beaussier; S Payen; J Chiras
Journal:  Interv Neuroradiol       Date:  2013-05-21       Impact factor: 1.610

  7 in total