Literature DB >> 9165682

Measurement of the pregnant cervix by transvaginal sonography: an interobserver study and new standards to improve the interobserver variability.

M Burger1, T Weber-Rössler, M Willmann.   

Abstract

Transvaginal sonography has become an important tool for assessing the gravid cervix uteri, especially in patients at risk for cervical incompetence and preterm delivery. The purpose of our prospective study was to evaluate interobserver variability in measurements of the cervical length and, as a second step, improve the reproducibility and interobserver discrepancy by the introduction of quality control standards when producing and measuring the image of the cervix. Before the introduction of these standards we obtained 46 measurements and observed a mean cervical length (internal to external os) of 33.7 mm (range 26-52 mm) and an interobserver average discrepancy of 3.04 mm (range 0-6 mm). Later, measurements were obtained only when the following conditions were assured and visualized on the screen: (1) the internal os is either flat or is an isosceles triangle; (2) the whole length of the cervical canal can be observed; (3) a symmetric image of the external os can be obtained; and (4) the distance from the surface of the posterior lip to the cervical canal is equal to the distance from the anterior lip to the cervical canal. After the implementation of these quality control standards, 70 measurements were performed obtaining a mean length of 35.3 mm (range 27-51) and an average interobserver discrepancy of 1.24 mm (range 0-4). Thus the measurement error was significantly lower following introduction of quality control standards. Furthermore, the coefficient of variation dropped from 7.1% to 3.3% after the introduction of the guidelines. We believe that these guidelines could be helpful by making the measurements of the cervical length more accurate, reducing the interobserver variability, improving the reproducibility and promoting the role of transvaginal sonography in monitoring the incompetent cervix.

Entities:  

Mesh:

Year:  1997        PMID: 9165682     DOI: 10.1046/j.1469-0705.1997.09030188.x

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  16 in total

1.  Transabdominal evaluation of uterine cervical length during pregnancy fails to identify a substantial number of women with a short cervix.

Authors:  Edgar Hernandez-Andrade; Roberto Romero; Hyunyoung Ahn; Youssef Hussein; Lami Yeo; Steven J Korzeniewski; Tinnakorn Chaiworapongsa; Sonia S Hassan
Journal:  J Matern Fetal Neonatal Med       Date:  2012-03-16

2.  Comparison of the POP-Q examination, transvaginal ultrasound, and direct anatomic measurement of cervical length.

Authors:  Christina E Dancz; Lisa Werth; Vanessa Sun; Sandy Lee; Daphne Walker; Begüm Özel
Journal:  Int Urogynecol J       Date:  2013-10-30       Impact factor: 2.894

3.  Effect of depth on shear-wave elastography estimated in the internal and external cervical os during pregnancy.

Authors:  Edgar Hernandez-Andrade; Alma Aurioles-Garibay; Maynor Garcia; Steven J Korzeniewski; Alyse G Schwartz; Hyunyoung Ahn; Alicia Martinez-Varea; Lami Yeo; Tinnakorn Chaiworapongsa; Sonia S Hassan; Roberto Romero
Journal:  J Perinat Med       Date:  2014-09       Impact factor: 1.901

4.  Quantitative elastography of the uterine cervix as a predictor of preterm delivery.

Authors:  K Köbbing; A Fruscalzo; K Hammer; M Möllers; M Falkenberg; R Kwiecien; W Klockenbusch; R Schmitz
Journal:  J Perinatol       Date:  2014-05-08       Impact factor: 2.521

5.  Cervical Sonoelastography and Cervical Length Measurement but not Cervicovaginal Interleukin-6 Are Predictors for Preterm Birth.

Authors:  A Weichert; D von Schöning; T Fischer; A Thomas
Journal:  Ultrasound Int Open       Date:  2016-08-24

6.  Strain at the internal cervical os assessed with quasi-static elastography is associated with the risk of spontaneous preterm delivery at ≤34 weeks of gestation.

Authors:  Edgar Hernandez-Andrade; Maynor Garcia; Hyunyoung Ahn; Steven J Korzeniewski; Homam Saker; Lami Yeo; Tinnakorn Chaiworapongsa; Sonia S Hassan; Roberto Romero
Journal:  J Perinat Med       Date:  2015-11       Impact factor: 1.901

7.  Cervical funneling: effect on gestational length and ultrasound-indicated cerclage in high-risk women.

Authors:  Melissa S Mancuso; Jeff M Szychowski; John Owen; Gary Hankins; Jay D Iams; Jeanne S Sheffield; Annette Perez-Delboy; Vincenzo Berghella; Debora A Wing; Edwin R Guzman
Journal:  Am J Obstet Gynecol       Date:  2010-09       Impact factor: 8.661

8.  Adherence to criteria for transvaginal ultrasound imaging and measurement of cervical length.

Authors:  Jay D Iams; William A Grobman; Albina Lozitska; Catherine Y Spong; George Saade; Brian M Mercer; Alan T Tita; Dwight J Rouse; Yoram Sorokin; Ronald J Wapner; Kenneth J Leveno; Sean C Blackwell; M Sean Esplin; Jorge E Tolosa; John M Thorp; Steve N Caritis; Peter J Van Dorsten
Journal:  Am J Obstet Gynecol       Date:  2013-08-16       Impact factor: 8.661

9.  Evaluation of cervical stiffness during pregnancy using semiquantitative ultrasound elastography.

Authors:  E Hernandez-Andrade; S S Hassan; H Ahn; S J Korzeniewski; L Yeo; T Chaiworapongsa; R Romero
Journal:  Ultrasound Obstet Gynecol       Date:  2013-01-08       Impact factor: 7.299

Review 10.  Prevention of preterm birth based on a short cervix: cerclage.

Authors:  Melissa S Mancuso; John Owen
Journal:  Semin Perinatol       Date:  2009-10       Impact factor: 3.300

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.