Literature DB >> 9157160

Rapid diagnosis of Legionella pneumophila serogroup 1 infection with the Binax enzyme immunoassay urinary antigen test.

D Kazandjian1, R Chiew, G L Gilbert.   

Abstract

The Binax legionella urinary antigen (LUA) enzyme immunoassay (Binax, Portland, Maine) was evaluated in 159 patients with suspected or proven legionellosis and 209 controls. A positive LUA test was found in 37% of patients with suspected legionellosis overall and in 83% of those with proven Legionella pneumophila serogroup 1 infection. The sensitivity of the LUA test was significantly greater than that of the direct fluorescent-antigen test (83 versus 42%; P < 0.0001) but not significantly different from that of culture (85%) or serology (91%); specificity was at least 99.5%.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9157160      PMCID: PMC229708          DOI: 10.1128/jcm.35.4.954-956.1997

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  12 in total

1.  Prevalence and diagnosis of Legionella pneumonia: a 3-year prospective study with emphasis on application of urinary antigen detection.

Authors:  B Ruf; D Schürmann; I Horbach; F J Fehrenbach; H D Pohle
Journal:  J Infect Dis       Date:  1990-12       Impact factor: 5.226

2.  Dust control in measles wards, with a note on sulphadiazine prophylaxis.

Authors:  N D BEGG; E W SMELLIE; J WRIGHT
Journal:  Br Med J       Date:  1947-02-08

3.  A prospective hospital study of the aetiology of community-acquired pneumonia.

Authors:  I Lim; D R Shaw; D P Stanley; R Lumb; G McLennan
Journal:  Med J Aust       Date:  1989-07-17       Impact factor: 7.738

4.  Rapid detection of Legionella species in bronchoalveolar lavage fluids with the EnviroAmp Legionella PCR amplification and detection kit.

Authors:  H H Kessler; F F Reinthaler; A Pschaid; K Pierer; B Kleinhappl; E Eber; E Marth
Journal:  J Clin Microbiol       Date:  1993-12       Impact factor: 5.948

5.  Recent advances in the diagnosis of serogroup 1 L. pneumophila pneumonia by detection of urinary antigen.

Authors:  R B Kohler; B Sathapatayavongs
Journal:  Zentralbl Bakteriol Mikrobiol Hyg A       Date:  1983-07

6.  Characterisation of Legionella pneumophila antigen in urine of guinea pigs and humans with Legionnaires' disease.

Authors:  A Williams; M S Lever
Journal:  J Infect       Date:  1995-01       Impact factor: 6.072

7.  Microbiological aspects of an outbreak of Legionnaires' disease in south western Sydney.

Authors:  R Munro; S Neville; D Daley; J Mercer
Journal:  Pathology       Date:  1994-01       Impact factor: 5.306

8.  Detection of Legionella pneumonophila antigen in urine by enzyme-linked immunospecific assay.

Authors:  B P Berdal; C E Farshy; J C Feeley
Journal:  J Clin Microbiol       Date:  1979-05       Impact factor: 5.948

9.  Legionnaires' disease antigen detected by enzyme-linked immunosorbent assay.

Authors:  R C Tilton
Journal:  Ann Intern Med       Date:  1979-04       Impact factor: 25.391

10.  Detection of Legionella DNA in human and guinea pig urine samples by the polymerase chain reaction.

Authors:  M Maiwald; M Schill; C Stockinger; J H Helbig; P C Lück; W Witzleb; H G Sonntag
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1995-01       Impact factor: 3.267

View more
  19 in total

Review 1.  Diagnosis of Legionella infection in Legionnaires' disease.

Authors:  J W Den Boer; E P F Yzerman
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2004-12       Impact factor: 3.267

2.  Evaluation of the Binax and Biotest urinary antigen kits for detection of Legionnaires' disease due to multiple serogroups and species of Legionella.

Authors:  R F Benson; P W Tang; B S Fields
Journal:  J Clin Microbiol       Date:  2000-07       Impact factor: 5.948

3.  Legionnaires disease presenting as acute kidney injury in the absence of pneumonia.

Authors:  Meera Yogarajah; Bhradeev Sivasambu
Journal:  BMJ Case Rep       Date:  2015-02-17

4.  Two-step scheme for rapid identification and differentiation of Legionella pneumophila and non-Legionella pneumophila species.

Authors:  Xiao-Yong Zhan; Lian-Qing Li; Chao-Hui Hu; Qing-Yi Zhu
Journal:  J Clin Microbiol       Date:  2009-12-09       Impact factor: 5.948

5.  Detection of Legionella pneumophila by real-time PCR for the mip gene.

Authors:  Deborah A Wilson; Belinda Yen-Lieberman; Udo Reischl; Steve M Gordon; Gary W Procop
Journal:  J Clin Microbiol       Date:  2003-07       Impact factor: 5.948

6.  Characterization of a lipoprotein common to Legionella species as a urinary broad-spectrum antigen for diagnosis of Legionnaires' disease.

Authors:  Min Ja Kim; Jang Wook Sohn; Dae Won Park; Seung Chul Park; Byung Chul Chun
Journal:  J Clin Microbiol       Date:  2003-07       Impact factor: 5.948

7.  Comparison of the Binax Legionella urinary antigen enzyme immunoassay (EIA) with the Biotest Legionella Urin antigen EIA for detection of Legionella antigen in both concentrated and nonconcentrated urine samples.

Authors:  J A Domínguez; N Galí; P Pedroso; A Fargas; E Padilla; J M Manterola; L Matas
Journal:  J Clin Microbiol       Date:  1998-09       Impact factor: 5.948

8.  Clinical utility of a Legionella pneumophila urinary antigen test in a large university teaching hospital.

Authors:  Michel Dionne; Todd Hatchette; Kevin Forward
Journal:  Can J Infect Dis       Date:  2003-03

Review 9.  Legionella and Legionnaires' disease: 25 years of investigation.

Authors:  Barry S Fields; Robert F Benson; Richard E Besser
Journal:  Clin Microbiol Rev       Date:  2002-07       Impact factor: 26.132

10.  Direct detection and differentiation of Legionella spp. and Legionella pneumophila in clinical specimens by dual-color real-time PCR and melting curve analysis.

Authors:  Udo Reischl; Hans-Jörg Linde; Norbert Lehn; Olfert Landt; Kevin Barratt; Nele Wellinghausen
Journal:  J Clin Microbiol       Date:  2002-10       Impact factor: 5.948

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.