Literature DB >> 9151610

The use of palatal implants for orthodontic anchorage. Design and clinical application of the orthosystem.

H Wehrbein1, B R Merz, P Diedrich, J Glatzmaier.   

Abstract

This paper presents the Orthosystem (Institute Straumann, Waldenburg/ Switzerland), a new endosseous orthodontic implant anchor system for palatal anchorage. The Orthosystem may replace compliance dependent extraoral anchoring aids for orthodontics and makes a bonding of well aligned mandibular dentition and it's use with class II elastics unnecessary. The fixture is designed for a one-stage application. It consists of an implant of pure titanium with a surface-treated, screw-shaped endosseous part of 3.3 mm diameter and lengths of 4 and 6 mm. Above the polished transmucosal neck follows as abutment where transpalatal arches made of rigid orthodontic wires (0.032 x 0.032 inch) are fixed by means of a clamp-cap. 6 patients with an angle class II malocclusion were implanted with the 6 mm fixture in the proximal midsagittal region of the palate during a pilot study. The treatment goal was extraction of the first maxillary premolars with subsequent retraction of the frontal dentition under maximal anchorage of the lateral teeth. For the implantation a simple surgical procedure of 10 min length was required while no further invasive action are needed until explantation. This way the strain on the patients was reduced to a minimum. They are now at varying stages of active treatment and the most advanced case is demonstrated here. The clinical and radiological findings after 12 months of treatment comprising 3 months of healing revealed no implant mobility or dislocation, favourable periimplant soft tissue conditions, and no marked mesial movement of the implant supported teeth. The frontal dentition was retracted by 8 mm with space closure occurring in a relatively short treatment period.

Entities:  

Mesh:

Year:  1996        PMID: 9151610     DOI: 10.1034/j.1600-0501.1996.070416.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  24 in total

1.  Assessing bone volume for orthodontic miniplate fixation below the maxillary frontal process.

Authors:  T M Präger; H G Brochhagen; R Mischkowski; P-G Jost-Brinkmann; R Müller-Hartwich
Journal:  J Orofac Orthop       Date:  2014-08-28       Impact factor: 1.938

2.  Upper molar distalization with skeletally anchored TopJet appliance.

Authors:  Bernhard C Pseiner; Anne Wunderlich; Josef W Freudenthaler
Journal:  J Orofac Orthop       Date:  2014-01-19       Impact factor: 1.938

3.  Comparative evaluation of anchorage reinforcement between orthodontic implants and conventional anchorage in orthodontic management of bimaxillary dentoalveolar protrusion.

Authors:  S S Chopra; Manish Mukherjee; Rajat Mitra; Gagan Deep Kochar; Abhijeet Kadu
Journal:  Med J Armed Forces India       Date:  2016-03-02

4.  The use of mini-implants in en masse retraction for the treatment of bimaxillary dentoalveolar protrusion.

Authors:  Ali Aljhani; Khalid H Zawawi
Journal:  Saudi Dent J       Date:  2009-12-29

5.  Treatment efficiency of mini-implant-borne distalization depending on age and second-molar eruption.

Authors:  M Nienkemper; B Wilmes; A Pauls; S Yamaguchi; B Ludwig; D Drescher
Journal:  J Orofac Orthop       Date:  2014-03-02       Impact factor: 1.938

6.  Patients' and orthodontists' perceptions of miniplates used for temporary skeletal anchorage: a prospective study.

Authors:  Marie A Cornelis; Nicole R Scheffler; Catherine Nyssen-Behets; Hugo J De Clerck; J F Camilla Tulloch
Journal:  Am J Orthod Dentofacial Orthop       Date:  2008-01       Impact factor: 2.650

7.  Comparison of skeletal and conventional anchorage methods in conjunction with pre-operative decompensation of a skeletal class III malocclusion.

Authors:  Benedict Wilmes; Gudrun Olthoff; Dieter Drescher
Journal:  J Orofac Orthop       Date:  2009-08-02       Impact factor: 1.938

8.  Biologic stability of plasma ion-implanted miniscrews.

Authors:  Young-Chae Cho; Jung-Yul Cha; Chung-Ju Hwang; Young-Chel Park; Han-Sung Jung; Hyung-Seog Yu
Journal:  Korean J Orthod       Date:  2013-06-24       Impact factor: 1.372

9.  Multipurpose use of orthodontic mini-implants to achieve different treatment goals.

Authors:  M Nienkemper; B Wilmes; A Pauls; D Drescher
Journal:  J Orofac Orthop       Date:  2012-10-28       Impact factor: 1.938

10.  Distalization pattern of the maxillary arch depending on the number of orthodontic miniscrews.

Authors:  Till E Bechtold; Jin-Wook Kim; Tae-Hyun Choi; Young-Chel Park; Kee-Joon Lee
Journal:  Angle Orthod       Date:  2012-09-12       Impact factor: 2.079

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.