Literature DB >> 9144369

Evaluation of a method for counting absolute numbers of cells with a flow cytometer.

J K Nicholson1, D Stein, T Mui, R Mack, M Hubbard, T Denny.   

Abstract

We evaluated a method for performing absolute cell counts of lymphocyte populations with a flow cytometer. In this method, TruCount, test tubes that contain a known number of brightly fluorescent polystyrene beads are provided by the manufacturer. Whole anticoagulated blood is accurately pipetted into the tubes and mixed with fluorochrome-labeled monoclonal antibodies, the erythrocytes are lysed, and this mixture is analyzed on the flow cytometer. Absolute counts of lymphocyte subsets are calculated by determining the ratio of beads to the cell population of interest and then multiplying this ratio by the number of beads in the tube. We found this method to be reproducible. The values we obtained by the TruCount method were 5 to 10% higher than those obtained by conventional methods (flow cytometry and automated hematology) used to determine absolute numbers of cells. We believe that these differences are due to the methods of determining absolute cell counts and not to faulty identification of lymphocyte subsets.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9144369      PMCID: PMC170524          DOI: 10.1128/cdli.4.3.309-313.1997

Source DB:  PubMed          Journal:  Clin Diagn Lab Immunol        ISSN: 1071-412X


  9 in total

1.  Decline in CD4+ cell numbers reflects increase in HIV-1 replication.

Authors:  F De Wolf; M Roos; J M Lange; J T Houweling; R A Coutinho; J van der Noordaa; P T Schellekens; J Goudsmit
Journal:  AIDS Res Hum Retroviruses       Date:  1988-12       Impact factor: 2.205

2.  Immunologic differentiation of absolute lymphocyte count with an integrated flow cytometric system: a new concept for absolute T cell subset determinations.

Authors:  T J Mercolino; M C Connelly; E J Meyer; M D Knight; J W Parker; G T Stelzer; G DeChirico
Journal:  Cytometry       Date:  1995-03-15

3.  Evaluation of a dual-color flow cytometry immunophenotyping panel in a multicenter quality assurance program.

Authors:  E L Schenker; L E Hultin; K D Bauer; J Ferbas; J B Margolick; J V Giorgi
Journal:  Cytometry       Date:  1993

4.  A parallel evaluation of four automated hematology analyzers.

Authors:  S A Bentley; A Johnson; C A Bishop
Journal:  Am J Clin Pathol       Date:  1993-12       Impact factor: 2.493

5.  Determination of CD4 and CD8 lymphocyte subsets by a new alternative fluorescence immunoassay.

Authors:  T N Denny; B D Jensen; E I Gavin; A G Louzao; F A Vella; J M Oleske; W Wong
Journal:  Clin Diagn Lab Immunol       Date:  1995-05

6.  Comparison of CD4 cell count by a simple enzyme-linked immunosorbent assay using the TRAx CD4 test kit and by flow cytometry and hematology.

Authors:  H Paxton; M Pins; G Denton; A D McGonigle; P S Meisner; J P Phair
Journal:  Clin Diagn Lab Immunol       Date:  1995-01

7.  Evaluation of four alternative methodologies for determination of absolute CD4+ lymphocyte counts. The National Heart, Lung, and Blood Institute Retrovirus Epidemiology Donor Study.

Authors:  D Johnson; D Hirschkorn; M P Busch
Journal:  J Acquir Immune Defic Syndr Hum Retrovirol       Date:  1995-12-15

8.  Evaluation of alternative CD4 technologies for the enumeration of CD4 lymphocytes.

Authors:  J K Nicholson; W M Velleca; S Jubert; T A Green; L Bryan
Journal:  J Immunol Methods       Date:  1994-12-28       Impact factor: 2.303

Review 9.  CD4+ T-lymphocyte measures in the treatment of individuals infected with human immunodeficiency virus type 1. A review for clinical practitioners.

Authors:  B J Turner; F M Hecht; R B Ismail
Journal:  Arch Intern Med       Date:  1994-07-25
  9 in total
  19 in total

1.  Integrin antagonists prevent costimulatory blockade-resistant transplant rejection by CD8(+) memory T cells.

Authors:  W H Kitchens; D Haridas; M E Wagener; M Song; A D Kirk; C P Larsen; M L Ford
Journal:  Am J Transplant       Date:  2011-09-22       Impact factor: 8.086

2.  Evaluation of a new single-parameter volumetric flow cytometer (CyFlow(green)) for enumeration of absolute CD4+ T lymphocytes in human immunodeficiency virus type 1-infected Thai patients.

Authors:  Kovit Pattanapanyasat; Surada Lerdwana; Egarit Noulsri; Thanyanan Chaowanachan; Punneeporn Wasinrapee; Natthaga Sakulploy; Vallerut Pobkeeree; Orapin Suksripanich; Sombat Thanprasertsuk; Thomas J Spira; Jordan W Tappero; William C Levine
Journal:  Clin Diagn Lab Immunol       Date:  2005-12

3.  Immunohematological reference values for healthy adults in Burkina Faso.

Authors:  N Klose; B Coulibaly; D M Tebit; F Nauwelaers; H P Spengler; G Kynast-Wolf; B Kouyaté; H-G Kräusslich; T Böhler
Journal:  Clin Vaccine Immunol       Date:  2007-04-18

4.  Influence of physical activity on the immune system in breast cancer patients during chemotherapy.

Authors:  Thorsten Schmidt; Walter Jonat; Daniela Wesch; Hans-Heinrich Oberg; Sabine Adam-Klages; Lisa Keller; Christoph Röcken; Christoph Mundhenke
Journal:  J Cancer Res Clin Oncol       Date:  2018-01-05       Impact factor: 4.553

5.  Absolute CD4 counts obtained by a three-color flow-cytometric method without the use of a hematology analyzer.

Authors:  T S Alexander
Journal:  Clin Diagn Lab Immunol       Date:  1998-03

6.  Automated leukocyte processing by microfluidic deterministic lateral displacement.

Authors:  Curt I Civin; Tony Ward; Alison M Skelley; Khushroo Gandhi; Zendra Peilun Lee; Christopher R Dosier; Joseph L D'Silva; Yu Chen; MinJung Kim; James Moynihan; Xiaochun Chen; Lee Aurich; Sergei Gulnik; George C Brittain; Diether J Recktenwald; Robert H Austin; James C Sturm
Journal:  Cytometry A       Date:  2016-11-22       Impact factor: 4.355

7.  Optimization of a whole blood phenotyping assay for enumeration of peripheral blood leukocyte populations in multicenter clinical trials.

Authors:  Tiffany Hensley-McBain; Antje Heit; Stephen C De Rosa; M Juliana McElrath; Erica Andersen-Nissen
Journal:  J Immunol Methods       Date:  2014-06-09       Impact factor: 2.303

8.  Islet xenograft destruction in the hu-PBL-severe combined immunodeficient (SCID) mouse necessitates anti-CD3 preactivation of human immune cells.

Authors:  C Gysemans; M Waer; J Laureys; J Depovere; D Pipeleers; R Bouillon; C Mathieu
Journal:  Clin Exp Immunol       Date:  2000-09       Impact factor: 4.330

9.  Purification of Enterocytozoon bieneusi spores from stool specimens by gradient and cell sorting techniques.

Authors:  Zuzana Kucerova; Hercules Moura; Gordon J Leitch; Rama Sriram; Caryn Bern; Vivian Kawai; Daniel Vargas; Robert H Gilman; Eduardo Ticona; Aldo Vivar; Govinda S Visvesvara
Journal:  J Clin Microbiol       Date:  2004-07       Impact factor: 5.948

10.  An immunomagnetic single-platform image cytometer for cell enumeration based on antibody specificity.

Authors:  Xiao Li; Arjan G J Tibbe; Erik Droog; Leon W M M Terstappen; Jan Greve
Journal:  Clin Vaccine Immunol       Date:  2007-02-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.