Literature DB >> 16339065

Evaluation of a new single-parameter volumetric flow cytometer (CyFlow(green)) for enumeration of absolute CD4+ T lymphocytes in human immunodeficiency virus type 1-infected Thai patients.

Kovit Pattanapanyasat1, Surada Lerdwana, Egarit Noulsri, Thanyanan Chaowanachan, Punneeporn Wasinrapee, Natthaga Sakulploy, Vallerut Pobkeeree, Orapin Suksripanich, Sombat Thanprasertsuk, Thomas J Spira, Jordan W Tappero, William C Levine.   

Abstract

Use of the standard dual-platform flow cytometric method for determination of CD4(+) T-lymphocyte counts, which needs both a flow cytometer (FCM) and hematological analyzer, would inevitably lead to increased variability. The development of new single-platform (SP) FCMs that provide direct CD4(+) T-lymphocyte counts for improved assay precision and accuracy have recently attracted attention. This study evaluated one of those systems, CyFlow(green) (Partec), a single-parameter SP volumetric FCM. The performance of CyFlow(green) was compared with those of two reference standard SP microbead-based technologies of the three-color TruCOUNT tube with the FACScan FCM and a two-color FACSCount system (Becton Dickinson Biosciences). Absolute CD4(+) and CD8(+) T-lymphocyte counts in 200 human immunodeficiency virus type 1-seropositive blood specimens were determined. Statistical analysis for correlation and agreement were performed. A high correlation of absolute CD4 counts was shown when those obtained with CyFlow(green) were compared with those obtained with the bead-based three-color TruCOUNT system (R(2)=0.96; mean bias, -69.1 cells/microl; 95% confidence interval [CI], -225.7 to+87.5 cells/microl) and the FACSCount system (R(2)=0.97; mean bias, -40.0 cells/microl; 95% CI, -165.1 to+85.1 cells/microl). The correlation of the CD4(+) T-lymphocyte counts obtained by the two bead-based systems was high (R(2)=0.98). Interestingly, CyFlow(green) yielded CD4(+) T-lymphocyte counts that were 21.8 and 7.2 cells/microl lower than those obtained with the TruCOUNT and the FACSCount systems, respectively, when CD4(+) T-lymphocyte counts were <250 CD4(+) T-lymphocyte counts/microl range or 17.3 and 5.8 cells/microl less, respectively, when CD4(+) T-lymphocyte counts were <200 cells/microl. The single-parameter CyFlow(green) volumetric technology performed well in comparison with the performance of the standard SP bead-based FCM system. However, a multicenter comparative study is needed before this FCM machine is implemented in resource-limited settings.

Entities:  

Mesh:

Year:  2005        PMID: 16339065      PMCID: PMC1317067          DOI: 10.1128/CDLI.12.12.1416-1424.2005

Source DB:  PubMed          Journal:  Clin Diagn Lab Immunol        ISSN: 1071-412X


  22 in total

1.  Microvolume fluorimetry for the determination of absolute CD4 and CD8 lymphocyte counts in patients with HIV: a comparative evaluation.

Authors:  D Glencross; L Scott; H Aggett; S Sonday; C S Scott
Journal:  Clin Lab Haematol       Date:  1999-12

2.  Affordable CD4+ T cell counts by flow cytometry. II. The use of fixed whole blood in resource-poor settings.

Authors:  V Jani; G Janossy; A Iqbal; F S Mhalu; E F Lyamuya; G Biberfeld; D K Glencross; L Scott; J T Reilly; V Granger; D Barnett
Journal:  J Immunol Methods       Date:  2001-11-01       Impact factor: 2.303

3.  Affordable CD4(+) T-cell counts on 'single-platform' flow cytometers I. Primary CD4 gating.

Authors:  G Janossy; I Jani; W Göhde
Journal:  Br J Haematol       Date:  2000-12       Impact factor: 6.998

4.  Effect of type of haematology analyser on CD4 count.

Authors:  G Robinson; L Morgan; M Evans; S McDermott; S Pereira; M Wansbrough-Jones; G Griffin
Journal:  Lancet       Date:  1992-08-22       Impact factor: 79.321

5.  Affordable CD4(+)-T-cell counting by flow cytometry: CD45 gating for volumetric analysis.

Authors:  George Janossy; Ilesh V Jani; Nicholas J Bradley; Arsene Bikoue; Tim Pitfield; Debbie K Glencross
Journal:  Clin Diagn Lab Immunol       Date:  2002-09

6.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

Review 7.  Cytofluorometric methods for assessing absolute numbers of cell subsets in blood. European Working Group on Clinical Cell Analysis.

Authors:  B Brando; D Barnett; G Janossy; F Mandy; B Autran; G Rothe; B Scarpati; G D'Avanzo; J L D'Hautcourt; R Lenkei; G Schmitz; A Kunkl; R Chianese; S Papa; J W Gratama
Journal:  Cytometry       Date:  2000-12-15

8.  Guidelines for performing single-platform absolute CD4+ T-cell determinations with CD45 gating for persons infected with human immunodeficiency virus. Centers for Disease Control and Prevention.

Authors:  Francis F Mandy; Janet K A Nicholson; J Steven McDougal
Journal:  MMWR Recomm Rep       Date:  2003-01-31

9.  The "vanishing counting bead" phenomenon: effect on absolute CD34+ cell counting in phosphate-buffered saline-diluted leukapheresis samples.

Authors:  B Brando; W Göhde; B Scarpati; G D'Avanzo
Journal:  Cytometry       Date:  2001-02-01

10.  Sources of variability in repeated T-helper lymphocyte counts from human immunodeficiency virus type 1-infected patients: total lymphocyte count fluctuations and diurnal cycle are important.

Authors:  J L Malone; T E Simms; G C Gray; K F Wagner; J R Burge; D S Burke
Journal:  J Acquir Immune Defic Syndr (1988)       Date:  1990
View more
  10 in total

1.  Evaluation of the Partec flow cytometer against the BD FACSCalibur system for monitoring immune responses of human immunodeficiency virus-infected patients in Zimbabwe.

Authors:  Justen Manasa; Hazvineyi Musabaike; Collen Masimirembwa; Eileen Burke; Ruedi Luthy; James Mudzori
Journal:  Clin Vaccine Immunol       Date:  2007-01-31

Review 2.  Low-cost assays for monitoring HIV infected individuals in resource-limited settings.

Authors:  Pachamuthu Balakrishnan; Hussain Syed Iqbal; Saravanan Shanmugham; Janardhanan Mohanakrishnan; Sunil S Solomon; Kenneth H Mayer; Suniti Solomon
Journal:  Indian J Med Res       Date:  2011-12       Impact factor: 2.375

3.  Affordable flow cytometry for enumeration of absolute CD4+ T-lymphocytes to identify subtype C HIV-1 infected adults requiring antiretroviral therapy (ART) and monitoring response to ART in a resource-limited setting.

Authors:  Lynn S Zijenah; Gerard Kadzirange; Simon Madzime; Margaret Borok; Chiedza Mudiwa; Ocean Tobaiwa; Mary Mucheche; Simbarashe Rusakaniko; David A Katzenstein
Journal:  J Transl Med       Date:  2006-08-14       Impact factor: 5.531

4.  Laboratory and field evaluation of the Partec CyFlow miniPOC for absolute and relative CD4 T-cell enumeration.

Authors:  Djibril Wade; Papa Alassane Diaw; Géraldine Daneau; Abdoul Aziz Diallo; Souleymane Mboup; Tandakha Ndiaye Dieye; Luc Kestens
Journal:  PLoS One       Date:  2015-02-17       Impact factor: 3.240

5.  Micro-a-fluidics ELISA for rapid CD4 cell count at the point-of-care.

Authors:  ShuQi Wang; Savas Tasoglu; Paul Z Chen; Michael Chen; Ragip Akbas; Sonya Wach; Cenk Ibrahim Ozdemir; Umut Atakan Gurkan; Francoise F Giguel; Daniel R Kuritzkes; Utkan Demirci
Journal:  Sci Rep       Date:  2014-01-22       Impact factor: 4.379

Review 6.  CD4 enumeration technologies: a systematic review of test performance for determining eligibility for antiretroviral therapy.

Authors:  Rosanna W Peeling; Kimberly A Sollis; Sarah Glover; Suzanne M Crowe; Alan L Landay; Ben Cheng; David Barnett; Thomas N Denny; Thomas J Spira; Wendy S Stevens; Siobhan Crowley; Shaffiq Essajee; Marco Vitoria; Nathan Ford
Journal:  PLoS One       Date:  2015-03-19       Impact factor: 3.240

7.  Performance verification of the new fully automated Aquios flow cytometer PanLeucogate (PLG) platform for CD4-T-lymphocyte enumeration in South Africa.

Authors:  Lindi-Marie Coetzee; Deborah K Glencross
Journal:  PLoS One       Date:  2017-11-03       Impact factor: 3.240

8.  Performance Evaluation of BD FACSPrestoTM Near-Patient CD4 Counter for Monitoring Antiretroviral Therapy in HIV-Infected Individuals in Primary Healthcare Clinics in Thailand.

Authors:  Kasama Sukapirom; Somrat Matchua; Charin Thepthai; Narinee Srimark; Ladawan Khowawisetsut; Kovit Pattanapanyasat
Journal:  Diagnostics (Basel)       Date:  2022-02-02

9.  CD4 T-cell enumeration in a field setting: evaluation of CyFlow counter using the CD4 easy count kit-dry and Pima CD4 systems.

Authors:  Djibril Wade; Papa Alassane Diaw; Géraldine Daneau; Makhtar Camara; Tandakha Ndiaye Dieye; Souleymane Mboup; Luc Kestens
Journal:  PLoS One       Date:  2013-09-16       Impact factor: 3.240

10.  Computed CD4 percentage as a low-cost method for determining pediatric antiretroviral treatment eligibility.

Authors:  Steven F J Callens; Faustin Kitetele; Jean Lusiama; Nicole Shabani; Samuel Edidi; Robert Colebunders; Frieda Behets; Annelies Van Rie
Journal:  BMC Infect Dis       Date:  2008-03-06       Impact factor: 3.090

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.