Literature DB >> 8249909

A parallel evaluation of four automated hematology analyzers.

S A Bentley1, A Johnson, C A Bishop.   

Abstract

A parallel evaluation was performed on four automated hematology analyzers: the Celldyn 3000 (Unipath Corp., Mountain View, CA), the Coulter STKS (Coulter Electronics Inc., Hialeah, FL), the Sysmex NE-8000 (Baxter Healthcare Corp., McGaw Park, IL), and the Technicon H*2 (Miles Corp., Tarrytown, NY). The protocol included evaluation of the complete blood count and differential leukocyte count (DLC) parameters. The DLC evaluation was performed using the National Committee for Clinical Laboratory Studies H20-A protocol. Based on this evaluation, the authors could not identify a single instrument that was clearly superior to the others. Overall, the four instruments were found to be safe and effective for diagnostic use; however, there were areas in which their performance was less than optimal. Particular questions were raised regarding the clinical usefulness of instrumental "flags" to identify qualitative leukocyte abnormalities. The results are discussed in relation to the selection of instruments for specific clinical applications.

Entities:  

Mesh:

Year:  1993        PMID: 8249909     DOI: 10.1093/ajcp/100.6.626

Source DB:  PubMed          Journal:  Am J Clin Pathol        ISSN: 0002-9173            Impact factor:   2.493


  4 in total

1.  Evaluation of TruCount absolute-count tubes for determining CD4 and CD8 cell numbers in human immunodeficiency virus-positive adults. Site Investigators and The NIAID DAIDS New Technologies Evaluation Group.

Authors:  C T Schnizlein-Bick; J Spritzler; C L Wilkening; J K Nicholson; M R O'Gorman
Journal:  Clin Diagn Lab Immunol       Date:  2000-05

2.  Affordable CD4(+)-T-cell counting by flow cytometry: CD45 gating for volumetric analysis.

Authors:  George Janossy; Ilesh V Jani; Nicholas J Bradley; Arsene Bikoue; Tim Pitfield; Debbie K Glencross
Journal:  Clin Diagn Lab Immunol       Date:  2002-09

3.  Evaluation of a method for counting absolute numbers of cells with a flow cytometer.

Authors:  J K Nicholson; D Stein; T Mui; R Mack; M Hubbard; T Denny
Journal:  Clin Diagn Lab Immunol       Date:  1997-05

4.  Inter- and intrainstitutional evaluation of automated volumetric capillary cytometry for the quantitation of CD4- and CD8-positive T lymphocytes in the peripheral blood of persons infected with human immunodeficiency virus. Site Investigators and the NIAID New CD4 Technologies Focus Group.

Authors:  M R O'Gorman; R Gelman
Journal:  Clin Diagn Lab Immunol       Date:  1997-03
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.