Literature DB >> 9139102

Cementless femoral revision arthroplasty. 2- to 5-year results with a modular titanium alloy stem.

J A Smith1, H K Dunn, B J Manaster.   

Abstract

Seventy-five consecutive cementless femoral revision arthroplasties were performed, using a modular titanium alloy stem (S-ROM, Joint Medical Products, Stamford, CT). Sixty-six hips were available for complete follow-up evaluation at 2 to 5 years (average, 3.4 years). Independent clinical analysis compared pre- with postoperative modified Harris hip scores and examined patient satisfaction. Independent radiographic analysis was also undertaken. There were two rerevisions, both for hematogenous sepsis. Of the rest, clinical scores improved from a preoperative value of 44 to a postoperative value of 83. Eighty-nine percent of patients were satisfied or very satisfied with the results of surgery. Fifty-two stems had solid bony ingrowth, seven were stabilized by fibrous tissue, and five were radiographically loose. Five-year survival, with rerevision as endpoint, was 96.4%.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9139102     DOI: 10.1016/s0883-5403(97)90066-8

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  6 in total

1.  Component version in modular total hip revision.

Authors:  Michael A Kopec; Aaron Pemberton; Joseph C Milbrandt; Gordon Allan
Journal:  Iowa Orthop J       Date:  2009

2.  Total hip arthroplasty using S-ROM prosthesis in elder patients with type C and B bone.

Authors:  Zhong-Shou Zhao; Jun-Ying Sun
Journal:  J Orthop       Date:  2013-05-16

3.  Midterm results following uncemented, modular, fully porous coated stem used in revision total hip arthroplasty: Comparison of two stem systems.

Authors:  Konrad Sebastian Wronka; Peter Herman Johan Cnudde
Journal:  J Orthop       Date:  2016-07-02

4.  [Titanium modular revision prosthesis stem in revision hip prosthesis].

Authors:  A Schuh; U Holzwarth; G Zeiler
Journal:  Orthopade       Date:  2004-01       Impact factor: 1.087

5.  Stem modularity alone is not effective in reducing dislocation rate in hip revision surgery.

Authors:  Dario Regis; Andrea Sandri; Pietro Bartolozzi
Journal:  J Orthop Traumatol       Date:  2009-11-18

6.  A Retrospective Single-Center Study of 23 Patients to Compare Gait Before and After Total Hip Arthroplasty Using the S-ROM Modular Hip System.

Authors:  Jacqueline Bahr; Dietmar Rosental; Tim Classen; Sonja Krebs; Marcus Jäger
Journal:  Med Sci Monit       Date:  2021-12-27